A study on the development of an ultrasonic system to measure cardiac output

碩士 === 中原大學 === 醫學工程研究所 === 92 === The patients after cardiac surgery often suffer from clinical problems associated with low blood pressure. The conditions of blood circulation for these patients having dangerous diseases relative to circulations should be thoroughly extracted and analyzed. In the...

Full description

Bibliographic Details
Main Authors: Huan-Sheng Hung, 洪煥昇
Other Authors: Shyh-Hau Wang
Format: Others
Language:zh-TW
Published: 2004
Online Access:http://ndltd.ncl.edu.tw/handle/h2s74j
id ndltd-TW-092CYCU5530027
record_format oai_dc
spelling ndltd-TW-092CYCU55300272019-05-15T19:37:51Z http://ndltd.ncl.edu.tw/handle/h2s74j A study on the development of an ultrasonic system to measure cardiac output 研發超音波系統以測量心輸出量之研究 Huan-Sheng Hung 洪煥昇 碩士 中原大學 醫學工程研究所 92 The patients after cardiac surgery often suffer from clinical problems associated with low blood pressure. The conditions of blood circulation for these patients having dangerous diseases relative to circulations should be thoroughly extracted and analyzed. In the past, the cardiac output was frequently measured by using the catheter inserted in a heart, and however, many researchers recently began to investigate the non-invasive approaches for the measurement of cardiac output, such as indicator dilution, Doppler ultrasound, and so forth. Compared to the traditional method based on Doppler ultrasound, this study developed an ultrasonic system to measure the flow by using ultrasonic signals in time-domain. The system was consisted of a 5 MHz ultrasonic pulser/receiver, an analog-to-digital converter, and an interface circuits. A software corresponding to the system was capable of real-time signal analysis and display. The feasibility and stability of the system was evaluated using the experiments on flowing blood in a tube that the range for the hematocrit and the flow is from 25% to 55% and from 62 ml/min to 437 ml/min, respectively. The relationship between hematocrit and flow was also explored. The results obtained from the flow experiments showed that the sensitivity of the measurement system to detect the variation of density was 5.38 corresponding to a correlation coefficient of 0.99 with those obtained from the measurement using the lock-in amplifier (SR844RF, Stanford Research Systems, USA). The experimental results also showed that both the volume and concentration of the indicator is proportional to the area of measurement of the curve. Moreover, the measured flow for higher hematocrits would be smaller than those from lower hematocrits. This is due to that the density of blood cell at high hematocrit is large, resulting in the increase of viscosity and the decrease of flow. This study concluded that this non-invasive ultrasonic measurement system has a high sensitivity to be helpful for the measurement of cardiac output in the clinical diagnosis. Shyh-Hau Wang 王士豪 2004 學位論文 ; thesis 70 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 中原大學 === 醫學工程研究所 === 92 === The patients after cardiac surgery often suffer from clinical problems associated with low blood pressure. The conditions of blood circulation for these patients having dangerous diseases relative to circulations should be thoroughly extracted and analyzed. In the past, the cardiac output was frequently measured by using the catheter inserted in a heart, and however, many researchers recently began to investigate the non-invasive approaches for the measurement of cardiac output, such as indicator dilution, Doppler ultrasound, and so forth. Compared to the traditional method based on Doppler ultrasound, this study developed an ultrasonic system to measure the flow by using ultrasonic signals in time-domain. The system was consisted of a 5 MHz ultrasonic pulser/receiver, an analog-to-digital converter, and an interface circuits. A software corresponding to the system was capable of real-time signal analysis and display. The feasibility and stability of the system was evaluated using the experiments on flowing blood in a tube that the range for the hematocrit and the flow is from 25% to 55% and from 62 ml/min to 437 ml/min, respectively. The relationship between hematocrit and flow was also explored. The results obtained from the flow experiments showed that the sensitivity of the measurement system to detect the variation of density was 5.38 corresponding to a correlation coefficient of 0.99 with those obtained from the measurement using the lock-in amplifier (SR844RF, Stanford Research Systems, USA). The experimental results also showed that both the volume and concentration of the indicator is proportional to the area of measurement of the curve. Moreover, the measured flow for higher hematocrits would be smaller than those from lower hematocrits. This is due to that the density of blood cell at high hematocrit is large, resulting in the increase of viscosity and the decrease of flow. This study concluded that this non-invasive ultrasonic measurement system has a high sensitivity to be helpful for the measurement of cardiac output in the clinical diagnosis.
author2 Shyh-Hau Wang
author_facet Shyh-Hau Wang
Huan-Sheng Hung
洪煥昇
author Huan-Sheng Hung
洪煥昇
spellingShingle Huan-Sheng Hung
洪煥昇
A study on the development of an ultrasonic system to measure cardiac output
author_sort Huan-Sheng Hung
title A study on the development of an ultrasonic system to measure cardiac output
title_short A study on the development of an ultrasonic system to measure cardiac output
title_full A study on the development of an ultrasonic system to measure cardiac output
title_fullStr A study on the development of an ultrasonic system to measure cardiac output
title_full_unstemmed A study on the development of an ultrasonic system to measure cardiac output
title_sort study on the development of an ultrasonic system to measure cardiac output
publishDate 2004
url http://ndltd.ncl.edu.tw/handle/h2s74j
work_keys_str_mv AT huanshenghung astudyonthedevelopmentofanultrasonicsystemtomeasurecardiacoutput
AT hónghuànshēng astudyonthedevelopmentofanultrasonicsystemtomeasurecardiacoutput
AT huanshenghung yánfāchāoyīnbōxìtǒngyǐcèliàngxīnshūchūliàngzhīyánjiū
AT hónghuànshēng yánfāchāoyīnbōxìtǒngyǐcèliàngxīnshūchūliàngzhīyánjiū
AT huanshenghung studyonthedevelopmentofanultrasonicsystemtomeasurecardiacoutput
AT hónghuànshēng studyonthedevelopmentofanultrasonicsystemtomeasurecardiacoutput
_version_ 1719091542922100736