Novel Calibration and Compensation Technique of Circuit <a href="http://www.ntsearch.com/search.php?q=Design&v=56">Design</a> for Biosensor
碩士 === 中原大學 === 電子工程研究所 === 92 === In this study, characteristics of the sodium ion selective electrode of different sensing areas based on the separative extended gate field effect transistor are analyzed, such as sensitivity, saturated performance in high concentration, current-voltage characteris...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | zh-TW |
Published: |
2004
|
Online Access: | http://ndltd.ncl.edu.tw/handle/4hu7me |
id |
ndltd-TW-092CYCU5428028 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-092CYCU54280282018-06-25T06:06:10Z http://ndltd.ncl.edu.tw/handle/4hu7me Novel Calibration and Compensation Technique of Circuit <a href="http://www.ntsearch.com/search.php?q=Design&v=56">Design</a> for Biosensor 應用於生物感測器之新型校正與補償技術電路 Han-Chou Liao 廖漢洲 碩士 中原大學 電子工程研究所 92 In this study, characteristics of the sodium ion selective electrode of different sensing areas based on the separative extended gate field effect transistor are analyzed, such as sensitivity, saturated performance in high concentration, current-voltage characteristics, and noise. Moreover, <a href="http://www.ntsearch.com/search.php?q=time&v=56">time</a> of the signal obtained is determined by stable <a href="http://www.ntsearch.com/search.php?q=time&v=56">time</a> of biosensor. Furthermore, the potentiometric sensor and amperometric sensor are based on the same measurement circuit system. However, the potentiometric sensor has the problem of the offset voltage, the offset cancellation circuit is used to cancel the offset voltage, and then accuracy can be increased. Eventually, the problems of stabilization and accuracy include the drift effect and hysteresis effect. The novel hysteresis calibration method and drift calibration circuit are used to calibrate these effects, and then stabilization and accuracy of sensor are increased. Shen-Kan Hsiung 熊慎幹 2004 學位論文 ; thesis 146 zh-TW |
collection |
NDLTD |
language |
zh-TW |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 中原大學 === 電子工程研究所 === 92 === In this study, characteristics of the sodium ion selective electrode of different sensing areas based on the separative extended gate field effect transistor are analyzed, such as sensitivity, saturated performance in high concentration, current-voltage characteristics, and noise. Moreover, <a href="http://www.ntsearch.com/search.php?q=time&v=56">time</a> of the signal obtained is determined by stable <a href="http://www.ntsearch.com/search.php?q=time&v=56">time</a> of biosensor. Furthermore, the potentiometric sensor and amperometric sensor are based on the same measurement circuit system. However, the potentiometric sensor has the problem of the offset voltage, the offset cancellation circuit is used to cancel the offset voltage, and then accuracy can be increased. Eventually, the problems of stabilization and accuracy include the drift effect and hysteresis effect. The novel hysteresis calibration method and drift calibration circuit are used to calibrate these effects, and then stabilization and accuracy of sensor are increased.
|
author2 |
Shen-Kan Hsiung |
author_facet |
Shen-Kan Hsiung Han-Chou Liao 廖漢洲 |
author |
Han-Chou Liao 廖漢洲 |
spellingShingle |
Han-Chou Liao 廖漢洲 Novel Calibration and Compensation Technique of Circuit <a href="http://www.ntsearch.com/search.php?q=Design&v=56">Design</a> for Biosensor |
author_sort |
Han-Chou Liao |
title |
Novel Calibration and Compensation Technique of Circuit <a href="http://www.ntsearch.com/search.php?q=Design&v=56">Design</a> for Biosensor |
title_short |
Novel Calibration and Compensation Technique of Circuit <a href="http://www.ntsearch.com/search.php?q=Design&v=56">Design</a> for Biosensor |
title_full |
Novel Calibration and Compensation Technique of Circuit <a href="http://www.ntsearch.com/search.php?q=Design&v=56">Design</a> for Biosensor |
title_fullStr |
Novel Calibration and Compensation Technique of Circuit <a href="http://www.ntsearch.com/search.php?q=Design&v=56">Design</a> for Biosensor |
title_full_unstemmed |
Novel Calibration and Compensation Technique of Circuit <a href="http://www.ntsearch.com/search.php?q=Design&v=56">Design</a> for Biosensor |
title_sort |
novel calibration and compensation technique of circuit <a href="http://www.ntsearch.com/search.php?q=design&v=56">design</a> for biosensor |
publishDate |
2004 |
url |
http://ndltd.ncl.edu.tw/handle/4hu7me |
work_keys_str_mv |
AT hanchouliao novelcalibrationandcompensationtechniqueofcircuitahrefhttpwwwntsearchcomsearchphpqdesignv56designaforbiosensor AT liàohànzhōu novelcalibrationandcompensationtechniqueofcircuitahrefhttpwwwntsearchcomsearchphpqdesignv56designaforbiosensor AT hanchouliao yīngyòngyúshēngwùgǎncèqìzhīxīnxíngxiàozhèngyǔbǔchángjìshùdiànlù AT liàohànzhōu yīngyòngyúshēngwùgǎncèqìzhīxīnxíngxiàozhèngyǔbǔchángjìshùdiànlù |
_version_ |
1718705404142157824 |