碩士 === 長庚大學 === 電機工程研究所 === 92 === As an increasing population of the elderly, chronic diseases not only affect the health of the citizen, but also spends lots of medical resources. Most of medical instruments are very huge that one should go to hospital for general health examination whi...

Full description

Bibliographic Details
Main Authors: Ming-Hsiung Yeh, 葉明雄
Other Authors: Hsiao-Lung Chan
Format: Others
Language:zh-TW
Published: 2004
Online Access:http://ndltd.ncl.edu.tw/handle/39032211488257218824
id ndltd-TW-092CGU00442010
record_format oai_dc
spelling ndltd-TW-092CGU004420102016-01-04T04:08:37Z http://ndltd.ncl.edu.tw/handle/39032211488257218824 Design of A Arterial Oxygen Saturation 無線傳輸血氧飽和量測系統設計 Ming-Hsiung Yeh 葉明雄 碩士 長庚大學 電機工程研究所 92 As an increasing population of the elderly, chronic diseases not only affect the health of the citizen, but also spends lots of medical resources. Most of medical instruments are very huge that one should go to hospital for general health examination which spends lots of resources. Therefore, the development of a home-care portable medical instrument is necessary to achieve a high-quality, low-cost and convenient health-care system. In this thesis, an arterial oxygen saturation (SaO2) monitoring system with wireless transmission is developed. The developed system is based on the MSP430F449 microprocessor (Texas Instrument, USA) and the nRF2401 wireless module (Nordic VLSI Corporation). The measured Sao2 is display on the LCD and transmitted to bedside home-care system via the wireless module. Besides, to achieve multiple access of personal medical information, a wireless communication protocol based on the slotted aloha was developed and implemented on the proposed portable SaO2 measurement system. Hsiao-Lung Chan 詹曉龍 2004 學位論文 ; thesis 72 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 長庚大學 === 電機工程研究所 === 92 === As an increasing population of the elderly, chronic diseases not only affect the health of the citizen, but also spends lots of medical resources. Most of medical instruments are very huge that one should go to hospital for general health examination which spends lots of resources. Therefore, the development of a home-care portable medical instrument is necessary to achieve a high-quality, low-cost and convenient health-care system. In this thesis, an arterial oxygen saturation (SaO2) monitoring system with wireless transmission is developed. The developed system is based on the MSP430F449 microprocessor (Texas Instrument, USA) and the nRF2401 wireless module (Nordic VLSI Corporation). The measured Sao2 is display on the LCD and transmitted to bedside home-care system via the wireless module. Besides, to achieve multiple access of personal medical information, a wireless communication protocol based on the slotted aloha was developed and implemented on the proposed portable SaO2 measurement system.
author2 Hsiao-Lung Chan
author_facet Hsiao-Lung Chan
Ming-Hsiung Yeh
葉明雄
author Ming-Hsiung Yeh
葉明雄
spellingShingle Ming-Hsiung Yeh
葉明雄
Design of A Arterial Oxygen Saturation
author_sort Ming-Hsiung Yeh
title Design of A Arterial Oxygen Saturation
title_short Design of A Arterial Oxygen Saturation
title_full Design of A Arterial Oxygen Saturation
title_fullStr Design of A Arterial Oxygen Saturation
title_full_unstemmed Design of A Arterial Oxygen Saturation
title_sort design of a arterial oxygen saturation
publishDate 2004
url http://ndltd.ncl.edu.tw/handle/39032211488257218824
work_keys_str_mv AT minghsiungyeh designofaarterialoxygensaturation
AT yèmíngxióng designofaarterialoxygensaturation
AT minghsiungyeh wúxiànchuánshūxuèyǎngbǎohéliàngcèxìtǒngshèjì
AT yèmíngxióng wúxiànchuánshūxuèyǎngbǎohéliàngcèxìtǒngshèjì
_version_ 1718158484206256128