Optimization-Based Reference Compensation Current Strategies for Shunt Active Power Filter Control
碩士 === 國立中正大學 === 電機工程研究所 === 92 === A new theory and a conceptual design for the three-phase shunt active power filter (APF) control strategy under imbalanced and distorted supply voltages are present in the thesis. Conventionally, the compensation currents injected by the APF are determined accord...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | zh-TW |
Published: |
2004
|
Online Access: | http://ndltd.ncl.edu.tw/handle/86757520007496567750 |
id |
ndltd-TW-092CCU00442058 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-092CCU004420582016-01-04T04:08:29Z http://ndltd.ncl.edu.tw/handle/86757520007496567750 Optimization-Based Reference Compensation Current Strategies for Shunt Active Power Filter Control 主動式電力濾波器以最佳化為基礎之參考補償電流演算策略 Chia-Ming Yeh 葉家銘 碩士 國立中正大學 電機工程研究所 92 A new theory and a conceptual design for the three-phase shunt active power filter (APF) control strategy under imbalanced and distorted supply voltages are present in the thesis. Conventionally, the compensation currents injected by the APF are determined according to reference frame transformation-based approaches, where the load instantaneous real and reactive powers are calculated in the new reference frame. The APF injection currents are then computed to maintain the balanced and sinusoidal source currents, as well as the least active power consumption by the APF. However, if current harmonics set by harmonic standards or other constraints are considered, the load harmonic currents after APF compensation can be controlled to meet the requirement. Therefore, the APF may have an adjustable performance. This thesis proposes an optimal algorithm for the APF control in steady state, where the individual and total harmonic current distortion limits, the minimum load power factor, levels of current imbalance, and the size of the APF can be taken into account. The planned APF does not consume or produce the active power and only the passive energy-storage elements are required in the new APF design. Results obtained by simulations with Matlab and Simulink show that the proposed approach is more flexible than the conventional approaches on compensating reactive power and harmonic/neutral currents of the load, even if the source voltages are severely distorted and imbalanced. The new control strategy is very suitable for planning the APF when several alternate objectives and constraints that are under considerations. Gary W. Chang 張文恭 2004 學位論文 ; thesis 120 zh-TW |
collection |
NDLTD |
language |
zh-TW |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 國立中正大學 === 電機工程研究所 === 92 === A new theory and a conceptual design for the three-phase shunt active power filter (APF) control strategy under imbalanced and distorted supply voltages are present in the thesis. Conventionally, the compensation currents injected by the APF are determined according to reference frame transformation-based approaches, where the load instantaneous real and reactive powers are calculated in the new reference frame. The APF injection currents are then computed to maintain the balanced and sinusoidal source currents, as well as the least active power consumption by the APF. However, if current harmonics set by harmonic standards or other constraints are considered, the load harmonic currents after APF compensation can be controlled to meet the requirement. Therefore, the APF may have an adjustable performance. This thesis proposes an optimal algorithm for the APF control in steady state, where the individual and total harmonic current distortion limits, the minimum load power factor, levels of current imbalance, and the size of the APF can be taken into account. The planned APF does not consume or produce the active power and only the passive energy-storage elements are required in the new APF design. Results obtained by simulations with Matlab and Simulink show that the proposed approach is more flexible than the conventional approaches on compensating reactive power and harmonic/neutral currents of the load, even if the source voltages are severely distorted and imbalanced. The new control strategy is very suitable for planning the APF when several alternate objectives and constraints that are under considerations.
|
author2 |
Gary W. Chang |
author_facet |
Gary W. Chang Chia-Ming Yeh 葉家銘 |
author |
Chia-Ming Yeh 葉家銘 |
spellingShingle |
Chia-Ming Yeh 葉家銘 Optimization-Based Reference Compensation Current Strategies for Shunt Active Power Filter Control |
author_sort |
Chia-Ming Yeh |
title |
Optimization-Based Reference Compensation Current Strategies for Shunt Active Power Filter Control |
title_short |
Optimization-Based Reference Compensation Current Strategies for Shunt Active Power Filter Control |
title_full |
Optimization-Based Reference Compensation Current Strategies for Shunt Active Power Filter Control |
title_fullStr |
Optimization-Based Reference Compensation Current Strategies for Shunt Active Power Filter Control |
title_full_unstemmed |
Optimization-Based Reference Compensation Current Strategies for Shunt Active Power Filter Control |
title_sort |
optimization-based reference compensation current strategies for shunt active power filter control |
publishDate |
2004 |
url |
http://ndltd.ncl.edu.tw/handle/86757520007496567750 |
work_keys_str_mv |
AT chiamingyeh optimizationbasedreferencecompensationcurrentstrategiesforshuntactivepowerfiltercontrol AT yèjiāmíng optimizationbasedreferencecompensationcurrentstrategiesforshuntactivepowerfiltercontrol AT chiamingyeh zhǔdòngshìdiànlìlǜbōqìyǐzuìjiāhuàwèijīchǔzhīcānkǎobǔchángdiànliúyǎnsuàncèlüè AT yèjiāmíng zhǔdòngshìdiànlìlǜbōqìyǐzuìjiāhuàwèijīchǔzhīcānkǎobǔchángdiànliúyǎnsuàncèlüè |
_version_ |
1718158223348858880 |