Optimization-Based Reference Compensation Current Strategies for Shunt Active Power Filter Control

碩士 === 國立中正大學 === 電機工程研究所 === 92 === A new theory and a conceptual design for the three-phase shunt active power filter (APF) control strategy under imbalanced and distorted supply voltages are present in the thesis. Conventionally, the compensation currents injected by the APF are determined accord...

Full description

Bibliographic Details
Main Authors: Chia-Ming Yeh, 葉家銘
Other Authors: Gary W. Chang
Format: Others
Language:zh-TW
Published: 2004
Online Access:http://ndltd.ncl.edu.tw/handle/86757520007496567750
id ndltd-TW-092CCU00442058
record_format oai_dc
spelling ndltd-TW-092CCU004420582016-01-04T04:08:29Z http://ndltd.ncl.edu.tw/handle/86757520007496567750 Optimization-Based Reference Compensation Current Strategies for Shunt Active Power Filter Control 主動式電力濾波器以最佳化為基礎之參考補償電流演算策略 Chia-Ming Yeh 葉家銘 碩士 國立中正大學 電機工程研究所 92 A new theory and a conceptual design for the three-phase shunt active power filter (APF) control strategy under imbalanced and distorted supply voltages are present in the thesis. Conventionally, the compensation currents injected by the APF are determined according to reference frame transformation-based approaches, where the load instantaneous real and reactive powers are calculated in the new reference frame. The APF injection currents are then computed to maintain the balanced and sinusoidal source currents, as well as the least active power consumption by the APF. However, if current harmonics set by harmonic standards or other constraints are considered, the load harmonic currents after APF compensation can be controlled to meet the requirement. Therefore, the APF may have an adjustable performance. This thesis proposes an optimal algorithm for the APF control in steady state, where the individual and total harmonic current distortion limits, the minimum load power factor, levels of current imbalance, and the size of the APF can be taken into account. The planned APF does not consume or produce the active power and only the passive energy-storage elements are required in the new APF design. Results obtained by simulations with Matlab and Simulink show that the proposed approach is more flexible than the conventional approaches on compensating reactive power and harmonic/neutral currents of the load, even if the source voltages are severely distorted and imbalanced. The new control strategy is very suitable for planning the APF when several alternate objectives and constraints that are under considerations. Gary W. Chang 張文恭 2004 學位論文 ; thesis 120 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立中正大學 === 電機工程研究所 === 92 === A new theory and a conceptual design for the three-phase shunt active power filter (APF) control strategy under imbalanced and distorted supply voltages are present in the thesis. Conventionally, the compensation currents injected by the APF are determined according to reference frame transformation-based approaches, where the load instantaneous real and reactive powers are calculated in the new reference frame. The APF injection currents are then computed to maintain the balanced and sinusoidal source currents, as well as the least active power consumption by the APF. However, if current harmonics set by harmonic standards or other constraints are considered, the load harmonic currents after APF compensation can be controlled to meet the requirement. Therefore, the APF may have an adjustable performance. This thesis proposes an optimal algorithm for the APF control in steady state, where the individual and total harmonic current distortion limits, the minimum load power factor, levels of current imbalance, and the size of the APF can be taken into account. The planned APF does not consume or produce the active power and only the passive energy-storage elements are required in the new APF design. Results obtained by simulations with Matlab and Simulink show that the proposed approach is more flexible than the conventional approaches on compensating reactive power and harmonic/neutral currents of the load, even if the source voltages are severely distorted and imbalanced. The new control strategy is very suitable for planning the APF when several alternate objectives and constraints that are under considerations.
author2 Gary W. Chang
author_facet Gary W. Chang
Chia-Ming Yeh
葉家銘
author Chia-Ming Yeh
葉家銘
spellingShingle Chia-Ming Yeh
葉家銘
Optimization-Based Reference Compensation Current Strategies for Shunt Active Power Filter Control
author_sort Chia-Ming Yeh
title Optimization-Based Reference Compensation Current Strategies for Shunt Active Power Filter Control
title_short Optimization-Based Reference Compensation Current Strategies for Shunt Active Power Filter Control
title_full Optimization-Based Reference Compensation Current Strategies for Shunt Active Power Filter Control
title_fullStr Optimization-Based Reference Compensation Current Strategies for Shunt Active Power Filter Control
title_full_unstemmed Optimization-Based Reference Compensation Current Strategies for Shunt Active Power Filter Control
title_sort optimization-based reference compensation current strategies for shunt active power filter control
publishDate 2004
url http://ndltd.ncl.edu.tw/handle/86757520007496567750
work_keys_str_mv AT chiamingyeh optimizationbasedreferencecompensationcurrentstrategiesforshuntactivepowerfiltercontrol
AT yèjiāmíng optimizationbasedreferencecompensationcurrentstrategiesforshuntactivepowerfiltercontrol
AT chiamingyeh zhǔdòngshìdiànlìlǜbōqìyǐzuìjiāhuàwèijīchǔzhīcānkǎobǔchángdiànliúyǎnsuàncèlüè
AT yèjiāmíng zhǔdòngshìdiànlìlǜbōqìyǐzuìjiāhuàwèijīchǔzhīcānkǎobǔchángdiànliúyǎnsuàncèlüè
_version_ 1718158223348858880