Study on Energy Saving of Appling Cascade System on Walk-in Refrigeration Show Cabinet

碩士 === 國立臺北科技大學 === 冷凍與低溫科技研究所 === 91 === Refrigerated display cabinets are widely used in 24-hr convenience store in Taiwan. In this research, we built a 5 in 1 closed type walk-in refrigerated display cabinet and its compression refrigeration system, which including traditional single s...

Full description

Bibliographic Details
Main Authors: Jenn Chyi Chung, 鐘震麒
Other Authors: Yang-Cheng Shih
Format: Others
Language:zh-TW
Published: 2003
Online Access:http://ndltd.ncl.edu.tw/handle/51912954238237127949
id ndltd-TW-091TIT00703007
record_format oai_dc
spelling ndltd-TW-091TIT007030072015-10-13T13:35:32Z http://ndltd.ncl.edu.tw/handle/51912954238237127949 Study on Energy Saving of Appling Cascade System on Walk-in Refrigeration Show Cabinet HFC二元冷凍系統應用於後補式冷凍展示櫃之節能研究 Jenn Chyi Chung 鐘震麒 碩士 國立臺北科技大學 冷凍與低溫科技研究所 91 Refrigerated display cabinets are widely used in 24-hr convenience store in Taiwan. In this research, we built a 5 in 1 closed type walk-in refrigerated display cabinet and its compression refrigeration system, which including traditional single stage compression system and cascade refrigeration system, to evaluate their system performance. The results of the performance test showed that the cascade refrigeration system adopting R134a and R507 combination has better system performance than the combination of R134a and R404A, and the power consumption test also showed 5 ~ 7% energy saving improved comparing with the single stage compression refrigeration system adopting R404A under the testing condition of 40℃ condensing temperature. Yang-Cheng Shih 施陽正 2003 學位論文 ; thesis 88 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立臺北科技大學 === 冷凍與低溫科技研究所 === 91 === Refrigerated display cabinets are widely used in 24-hr convenience store in Taiwan. In this research, we built a 5 in 1 closed type walk-in refrigerated display cabinet and its compression refrigeration system, which including traditional single stage compression system and cascade refrigeration system, to evaluate their system performance. The results of the performance test showed that the cascade refrigeration system adopting R134a and R507 combination has better system performance than the combination of R134a and R404A, and the power consumption test also showed 5 ~ 7% energy saving improved comparing with the single stage compression refrigeration system adopting R404A under the testing condition of 40℃ condensing temperature.
author2 Yang-Cheng Shih
author_facet Yang-Cheng Shih
Jenn Chyi Chung
鐘震麒
author Jenn Chyi Chung
鐘震麒
spellingShingle Jenn Chyi Chung
鐘震麒
Study on Energy Saving of Appling Cascade System on Walk-in Refrigeration Show Cabinet
author_sort Jenn Chyi Chung
title Study on Energy Saving of Appling Cascade System on Walk-in Refrigeration Show Cabinet
title_short Study on Energy Saving of Appling Cascade System on Walk-in Refrigeration Show Cabinet
title_full Study on Energy Saving of Appling Cascade System on Walk-in Refrigeration Show Cabinet
title_fullStr Study on Energy Saving of Appling Cascade System on Walk-in Refrigeration Show Cabinet
title_full_unstemmed Study on Energy Saving of Appling Cascade System on Walk-in Refrigeration Show Cabinet
title_sort study on energy saving of appling cascade system on walk-in refrigeration show cabinet
publishDate 2003
url http://ndltd.ncl.edu.tw/handle/51912954238237127949
work_keys_str_mv AT jennchyichung studyonenergysavingofapplingcascadesystemonwalkinrefrigerationshowcabinet
AT zhōngzhènqí studyonenergysavingofapplingcascadesystemonwalkinrefrigerationshowcabinet
AT jennchyichung hfcèryuánlěngdòngxìtǒngyīngyòngyúhòubǔshìlěngdòngzhǎnshìguìzhījiénéngyánjiū
AT zhōngzhènqí hfcèryuánlěngdòngxìtǒngyīngyòngyúhòubǔshìlěngdòngzhǎnshìguìzhījiénéngyánjiū
_version_ 1717738373598150656