Study on Infrared System in Thermal Measurements for Central Processing Unit

碩士 === 中國文化大學 === 資訊管理研究所 === 91 === In recent years due to rapid progress in semiconductor technology, the efficiency of Infrared Thermal Imaging Camera has been improved evidently but the product cost has been lowered. The technique of Infrared Thermal Imaging Camera has been developed and applied...

Full description

Bibliographic Details
Main Authors: Yuan-pu Liao, 廖元溥
Other Authors: 蔡敦仁
Format: Others
Language:zh-TW
Published: 2003
Online Access:http://ndltd.ncl.edu.tw/handle/57472936728175503822
id ndltd-TW-091PCCU0396008
record_format oai_dc
spelling ndltd-TW-091PCCU03960082015-10-13T13:35:28Z http://ndltd.ncl.edu.tw/handle/57472936728175503822 Study on Infrared System in Thermal Measurements for Central Processing Unit 紅外線熱像儀應用於電子零件品管─以CPU為例 Yuan-pu Liao 廖元溥 碩士 中國文化大學 資訊管理研究所 91 In recent years due to rapid progress in semiconductor technology, the efficiency of Infrared Thermal Imaging Camera has been improved evidently but the product cost has been lowered. The technique of Infrared Thermal Imaging Camera has been developed and applied to various fields, such as electronic facility maintenance, concrete detect, medical treatment, chemical industry, military, and geography. However, until now the main detecting techniques used to examine the finished product in the field of Taiwan Computer Industry still heavily relied on human detecting. Therefore, the purpose of the study is attempt to apply the technique of Infrared Thermal Imaging Camera to product detecting in production line, taking CPU as an example, in order to raise the likelihood of precise detection to achieve better quality management for final finished product. In terms of, both vdd and frequency perfectly correlate with temperature; that is to say, according CMOS power consumption formula, theoretically the correlation coeffi-cient of the CPU’s temperature obtained from the experiment and vdd will be close to 1, and so will be the correlation coefficient of the CPU’s temperature and frequency. Based on the inference, the likelihood of disorder of the working CPU has will be lowered. The results fit with the original expectations. That is, comparing with defect CPU, the correlation coefficient of the normal CPU is closer to ideal value, 1. Therefore, this study applies the results to generate a preliminary IR-CPU Detecting System. It is expected that the research design of this study can be expended to other types of detecting equipments such as ultrasound, X-ray. In addition, temperature analysis module adopted in this study can be applied to other kinds of physical data besides temperature. 蔡敦仁 2003 學位論文 ; thesis 94 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 中國文化大學 === 資訊管理研究所 === 91 === In recent years due to rapid progress in semiconductor technology, the efficiency of Infrared Thermal Imaging Camera has been improved evidently but the product cost has been lowered. The technique of Infrared Thermal Imaging Camera has been developed and applied to various fields, such as electronic facility maintenance, concrete detect, medical treatment, chemical industry, military, and geography. However, until now the main detecting techniques used to examine the finished product in the field of Taiwan Computer Industry still heavily relied on human detecting. Therefore, the purpose of the study is attempt to apply the technique of Infrared Thermal Imaging Camera to product detecting in production line, taking CPU as an example, in order to raise the likelihood of precise detection to achieve better quality management for final finished product. In terms of, both vdd and frequency perfectly correlate with temperature; that is to say, according CMOS power consumption formula, theoretically the correlation coeffi-cient of the CPU’s temperature obtained from the experiment and vdd will be close to 1, and so will be the correlation coefficient of the CPU’s temperature and frequency. Based on the inference, the likelihood of disorder of the working CPU has will be lowered. The results fit with the original expectations. That is, comparing with defect CPU, the correlation coefficient of the normal CPU is closer to ideal value, 1. Therefore, this study applies the results to generate a preliminary IR-CPU Detecting System. It is expected that the research design of this study can be expended to other types of detecting equipments such as ultrasound, X-ray. In addition, temperature analysis module adopted in this study can be applied to other kinds of physical data besides temperature.
author2 蔡敦仁
author_facet 蔡敦仁
Yuan-pu Liao
廖元溥
author Yuan-pu Liao
廖元溥
spellingShingle Yuan-pu Liao
廖元溥
Study on Infrared System in Thermal Measurements for Central Processing Unit
author_sort Yuan-pu Liao
title Study on Infrared System in Thermal Measurements for Central Processing Unit
title_short Study on Infrared System in Thermal Measurements for Central Processing Unit
title_full Study on Infrared System in Thermal Measurements for Central Processing Unit
title_fullStr Study on Infrared System in Thermal Measurements for Central Processing Unit
title_full_unstemmed Study on Infrared System in Thermal Measurements for Central Processing Unit
title_sort study on infrared system in thermal measurements for central processing unit
publishDate 2003
url http://ndltd.ncl.edu.tw/handle/57472936728175503822
work_keys_str_mv AT yuanpuliao studyoninfraredsysteminthermalmeasurementsforcentralprocessingunit
AT liàoyuánpǔ studyoninfraredsysteminthermalmeasurementsforcentralprocessingunit
AT yuanpuliao hóngwàixiànrèxiàngyíyīngyòngyúdiànzilíngjiànpǐnguǎnyǐcpuwèilì
AT liàoyuánpǔ hóngwàixiànrèxiàngyíyīngyòngyúdiànzilíngjiànpǐnguǎnyǐcpuwèilì
_version_ 1717737434505019392