碩士 === 國立中山大學 === 電機工程學系研究所 === 91 === The purpose of thesis is to investigate the transient stability and operation feasibility of power islanding with different type of dispersed generation in distribution system. A substation of Taipower system is selected for case study to simulate the system tr...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | zh-TW |
Published: |
2003
|
Online Access: | http://ndltd.ncl.edu.tw/handle/55540159203603223595 |
id |
ndltd-TW-091NSYS5442023 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-091NSYS54420232016-06-22T04:20:47Z http://ndltd.ncl.edu.tw/handle/55540159203603223595 Stability Analysis of Distribution System with Dispersed Generation 含分散式電源之配電系統穩定度分析 Yu-Shian Lin 林育賢 碩士 國立中山大學 電機工程學系研究所 91 The purpose of thesis is to investigate the transient stability and operation feasibility of power islanding with different type of dispersed generation in distribution system. A substation of Taipower system is selected for case study to simulate the system transient stability. The mathematical models of dispersed generations including exciters, governors of gas turbine and pitch controller of wind-driven induction generator are used in the simulation program. To represent the load behavior more accurately, the load ratio of residence, commercial, industrial customer class and the composition of electric equipments in feeder, such as induction motors, air conditioners etc, have been identified through load survey study. The load models of end users are employed in simulation to solve the power consumption as function of bus voltage and system frequency. Besides, the dynamic model of induction motors is integrated to solve more accurate system power demand under transient condition. The simulation analysis of transient stability is executed for unbalance distribution system with dispersed generations of gas turbines and wind-driven turbines with three operations sceneries after the distribution system has been disconnected from Taipower system. Different load shedding schemes and output power control of dispersed generation are considered to maintain the stable operation of islanding power system. It is suggested that the system reliability of power system can be enhanced by the dispersed power generation with proper design of load shedding in the transient stability analysis. Chao-Shun Chen 陳朝順 2003 學位論文 ; thesis 102 zh-TW |
collection |
NDLTD |
language |
zh-TW |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 國立中山大學 === 電機工程學系研究所 === 91 === The purpose of thesis is to investigate the transient stability and operation feasibility of power islanding with different type of dispersed generation in distribution system. A substation of Taipower system is selected for case study to simulate the system transient stability. The mathematical models of dispersed generations including exciters, governors of gas turbine and pitch controller of wind-driven induction generator are used in the simulation program. To represent the load behavior more accurately, the load ratio of residence, commercial, industrial customer class and the composition of electric equipments in feeder, such as induction motors, air conditioners etc, have been identified through load survey study. The load models of end users are employed in simulation to solve the power consumption as function of bus voltage and system frequency. Besides, the dynamic model of induction motors is integrated to solve more accurate system power demand under transient condition. The simulation analysis of transient stability is executed for unbalance distribution system with dispersed generations of gas turbines and wind-driven turbines with three operations sceneries after the distribution system has been disconnected from Taipower system. Different load shedding schemes and output power control of dispersed generation are considered to maintain the stable operation of islanding power system. It is suggested that the system reliability of power system can be enhanced by the dispersed power generation with proper design of load shedding in the transient stability analysis.
|
author2 |
Chao-Shun Chen |
author_facet |
Chao-Shun Chen Yu-Shian Lin 林育賢 |
author |
Yu-Shian Lin 林育賢 |
spellingShingle |
Yu-Shian Lin 林育賢 Stability Analysis of Distribution System with Dispersed Generation |
author_sort |
Yu-Shian Lin |
title |
Stability Analysis of Distribution System with Dispersed Generation |
title_short |
Stability Analysis of Distribution System with Dispersed Generation |
title_full |
Stability Analysis of Distribution System with Dispersed Generation |
title_fullStr |
Stability Analysis of Distribution System with Dispersed Generation |
title_full_unstemmed |
Stability Analysis of Distribution System with Dispersed Generation |
title_sort |
stability analysis of distribution system with dispersed generation |
publishDate |
2003 |
url |
http://ndltd.ncl.edu.tw/handle/55540159203603223595 |
work_keys_str_mv |
AT yushianlin stabilityanalysisofdistributionsystemwithdispersedgeneration AT línyùxián stabilityanalysisofdistributionsystemwithdispersedgeneration AT yushianlin hánfēnsànshìdiànyuánzhīpèidiànxìtǒngwěndìngdùfēnxī AT línyùxián hánfēnsànshìdiànyuánzhīpèidiànxìtǒngwěndìngdùfēnxī |
_version_ |
1718318522303512576 |