A Study on Data transmission by Power Line

碩士 === 國立高雄第一科技大學 === 電腦與通訊工程所 === 91 === A Study on Data Transmission by Power Line Student:Chyi-Taur Lin         Advisors:Dr. Wei-Chih Hsu Department of Computer and Communication Engineering National Kaohsiung First University of Science and Technology 英文摘要 ABSTRACT This paper presents a cha...

Full description

Bibliographic Details
Main Authors: Chyi-Taur Lin, 林祺濤
Other Authors: none
Format: Others
Language:zh-TW
Published: 2003
Online Access:http://ndltd.ncl.edu.tw/handle/07881770229968358481
id ndltd-TW-091NKIT5650007
record_format oai_dc
spelling ndltd-TW-091NKIT56500072016-06-22T04:20:20Z http://ndltd.ncl.edu.tw/handle/07881770229968358481 A Study on Data transmission by Power Line 電力線傳送數據之探討 Chyi-Taur Lin 林祺濤 碩士 國立高雄第一科技大學 電腦與通訊工程所 91 A Study on Data Transmission by Power Line Student:Chyi-Taur Lin         Advisors:Dr. Wei-Chih Hsu Department of Computer and Communication Engineering National Kaohsiung First University of Science and Technology 英文摘要 ABSTRACT This paper presents a characteristical measurement of power line to probe the possibility as a kind of communicational medium. The electric potential attenuation of power line against frequency has been measured by means of signal generator, frequency counter, and ocsilloscope. We wrote a program to measure the byte-loss rates of the server-to-client data transmission on the power lines with different lengths. Besides,we also investigated the influences of no-fuse breaker and the power with different phases on data transmission. In application, we constructed a PC-based power line communicator to control a programmable message sign. The alphanumerical characters were sent from the computer to the message sign for display. We also programmed a timing corrector to actively or passively transmit the date and the time of the server computer to the client computer for alignment. The experiments show that power line is capable of data transmission. The experimental results reveal that the electrical attenuation of power line varies with frequency. The transmission distance and the numbers of connected appliances also affect the loss rate of data transmission. none 徐偉智 2003 學位論文 ; thesis 169 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立高雄第一科技大學 === 電腦與通訊工程所 === 91 === A Study on Data Transmission by Power Line Student:Chyi-Taur Lin         Advisors:Dr. Wei-Chih Hsu Department of Computer and Communication Engineering National Kaohsiung First University of Science and Technology 英文摘要 ABSTRACT This paper presents a characteristical measurement of power line to probe the possibility as a kind of communicational medium. The electric potential attenuation of power line against frequency has been measured by means of signal generator, frequency counter, and ocsilloscope. We wrote a program to measure the byte-loss rates of the server-to-client data transmission on the power lines with different lengths. Besides,we also investigated the influences of no-fuse breaker and the power with different phases on data transmission. In application, we constructed a PC-based power line communicator to control a programmable message sign. The alphanumerical characters were sent from the computer to the message sign for display. We also programmed a timing corrector to actively or passively transmit the date and the time of the server computer to the client computer for alignment. The experiments show that power line is capable of data transmission. The experimental results reveal that the electrical attenuation of power line varies with frequency. The transmission distance and the numbers of connected appliances also affect the loss rate of data transmission.
author2 none
author_facet none
Chyi-Taur Lin
林祺濤
author Chyi-Taur Lin
林祺濤
spellingShingle Chyi-Taur Lin
林祺濤
A Study on Data transmission by Power Line
author_sort Chyi-Taur Lin
title A Study on Data transmission by Power Line
title_short A Study on Data transmission by Power Line
title_full A Study on Data transmission by Power Line
title_fullStr A Study on Data transmission by Power Line
title_full_unstemmed A Study on Data transmission by Power Line
title_sort study on data transmission by power line
publishDate 2003
url http://ndltd.ncl.edu.tw/handle/07881770229968358481
work_keys_str_mv AT chyitaurlin astudyondatatransmissionbypowerline
AT línqítāo astudyondatatransmissionbypowerline
AT chyitaurlin diànlìxiànchuánsòngshùjùzhītàntǎo
AT línqítāo diànlìxiànchuánsòngshùjùzhītàntǎo
AT chyitaurlin studyondatatransmissionbypowerline
AT línqítāo studyondatatransmissionbypowerline
_version_ 1718317503977881600