Acoustic Characteristics of Miniature PVDF Pressure Sensors
碩士 === 國立成功大學 === 機械工程學系碩博士班 === 91 === This study employed a excimer laser mirco-maching technique on a thick PVDF (polyvinylidene fluoride) piezoelectric film to fabricate miniature pressure sensors .The sizes of sensing area are 1.5mm×1.5mm and 2mm×2mm. To investigate the acoustic characteris...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | zh-TW |
Published: |
2003
|
Online Access: | http://ndltd.ncl.edu.tw/handle/69724472490766568381 |
id |
ndltd-TW-091NCKU5490147 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-091NCKU54901472016-06-22T04:14:03Z http://ndltd.ncl.edu.tw/handle/69724472490766568381 Acoustic Characteristics of Miniature PVDF Pressure Sensors 微小型PVDF壓力感測器之聲學特性研究 Thung-Jie Hwa 花聰傑 碩士 國立成功大學 機械工程學系碩博士班 91 This study employed a excimer laser mirco-maching technique on a thick PVDF (polyvinylidene fluoride) piezoelectric film to fabricate miniature pressure sensors .The sizes of sensing area are 1.5mm×1.5mm and 2mm×2mm. To investigate the acoustic characteristics of the sensors , acoustic fields generated by ultrasound transducers and hydrophones were used to test the sensors in frequencies of the orders of few MHz and tens of kHz respectively. Sensitivities of the sensors were obtained by comparing the sensor output to those of calibrated hydrophones which were located nearby in the same acoustic field. Yi-Chun Wang 王逸君 2003 學位論文 ; thesis 72 zh-TW |
collection |
NDLTD |
language |
zh-TW |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 國立成功大學 === 機械工程學系碩博士班 === 91 === This study employed a excimer laser mirco-maching technique on a thick PVDF (polyvinylidene fluoride) piezoelectric film to fabricate miniature pressure sensors .The sizes of sensing area are 1.5mm×1.5mm and 2mm×2mm.
To investigate the acoustic characteristics of the sensors , acoustic fields generated by ultrasound transducers and hydrophones were used to test the sensors in frequencies of the orders of few MHz and tens of kHz respectively.
Sensitivities of the sensors were obtained by comparing the sensor output to those of calibrated hydrophones which were located nearby in the same acoustic field.
|
author2 |
Yi-Chun Wang |
author_facet |
Yi-Chun Wang Thung-Jie Hwa 花聰傑 |
author |
Thung-Jie Hwa 花聰傑 |
spellingShingle |
Thung-Jie Hwa 花聰傑 Acoustic Characteristics of Miniature PVDF Pressure Sensors |
author_sort |
Thung-Jie Hwa |
title |
Acoustic Characteristics of Miniature PVDF Pressure Sensors |
title_short |
Acoustic Characteristics of Miniature PVDF Pressure Sensors |
title_full |
Acoustic Characteristics of Miniature PVDF Pressure Sensors |
title_fullStr |
Acoustic Characteristics of Miniature PVDF Pressure Sensors |
title_full_unstemmed |
Acoustic Characteristics of Miniature PVDF Pressure Sensors |
title_sort |
acoustic characteristics of miniature pvdf pressure sensors |
publishDate |
2003 |
url |
http://ndltd.ncl.edu.tw/handle/69724472490766568381 |
work_keys_str_mv |
AT thungjiehwa acousticcharacteristicsofminiaturepvdfpressuresensors AT huācōngjié acousticcharacteristicsofminiaturepvdfpressuresensors AT thungjiehwa wēixiǎoxíngpvdfyālìgǎncèqìzhīshēngxuétèxìngyánjiū AT huācōngjié wēixiǎoxíngpvdfyālìgǎncèqìzhīshēngxuétèxìngyánjiū |
_version_ |
1718314488093999104 |