A Study on Fire-Resistive Construction of Unitized Aluminum Curtain Wall

碩士 === 國立成功大學 === 建築學系碩博士班 === 91 === Generally speaking, the “curtain wall fire performance” test is based on the CNS 12514 (Method of fire resistance test for structural parts of building); however, as a matter of fact, people don’t test it through this standard method when confirming the function...

Full description

Bibliographic Details
Main Authors: I-Ting You, 游依婷
Other Authors: Bin Huang
Format: Others
Language:zh-TW
Published: 2003
Online Access:http://ndltd.ncl.edu.tw/handle/14701482625265335744
id ndltd-TW-091NCKU5222025
record_format oai_dc
spelling ndltd-TW-091NCKU52220252015-10-13T17:07:02Z http://ndltd.ncl.edu.tw/handle/14701482625265335744 A Study on Fire-Resistive Construction of Unitized Aluminum Curtain Wall 單元式鋁帷幕牆防火構法之研究 I-Ting You 游依婷 碩士 國立成功大學 建築學系碩博士班 91 Generally speaking, the “curtain wall fire performance” test is based on the CNS 12514 (Method of fire resistance test for structural parts of building); however, as a matter of fact, people don’t test it through this standard method when confirming the function of “curtain wall fire performance”. People don’t judge the fire performance by considering that the fire performance of the whole wall system could be the weakest point of preventing fire spread, but judge the “curtain wall fire performance” by the fire incombustibility of the constructed material of curtain wall. Especially, the fire performance of the common-used Unitized Aluminum Curtain Wall is quite controversial for the essence of the constructed material. Considering about the fact, this study attempts to clarify the relationship between the fire behavior in the buildings and the wall, to figure out the construction forms of domestic Unitized Aluminum Curtain Wall by reviewing studies and conveying the companies and experts, and to give some suggestions and problems exploring of Fire-Resistive Construction of Unitized Aluminum Curtain Wall by using the researches of buildings fire behavior. As it occurred that the relating background information is not enough for this Fire-Resistive Construction due to the domestic preliminary study level of the fire performance of curtain wall, this study also attempt to inform what is insufficient for supervising the related aspects and following researches while explore the problems and possible strategies. Bin Huang 黃斌 2003 學位論文 ; thesis 86 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立成功大學 === 建築學系碩博士班 === 91 === Generally speaking, the “curtain wall fire performance” test is based on the CNS 12514 (Method of fire resistance test for structural parts of building); however, as a matter of fact, people don’t test it through this standard method when confirming the function of “curtain wall fire performance”. People don’t judge the fire performance by considering that the fire performance of the whole wall system could be the weakest point of preventing fire spread, but judge the “curtain wall fire performance” by the fire incombustibility of the constructed material of curtain wall. Especially, the fire performance of the common-used Unitized Aluminum Curtain Wall is quite controversial for the essence of the constructed material. Considering about the fact, this study attempts to clarify the relationship between the fire behavior in the buildings and the wall, to figure out the construction forms of domestic Unitized Aluminum Curtain Wall by reviewing studies and conveying the companies and experts, and to give some suggestions and problems exploring of Fire-Resistive Construction of Unitized Aluminum Curtain Wall by using the researches of buildings fire behavior. As it occurred that the relating background information is not enough for this Fire-Resistive Construction due to the domestic preliminary study level of the fire performance of curtain wall, this study also attempt to inform what is insufficient for supervising the related aspects and following researches while explore the problems and possible strategies.
author2 Bin Huang
author_facet Bin Huang
I-Ting You
游依婷
author I-Ting You
游依婷
spellingShingle I-Ting You
游依婷
A Study on Fire-Resistive Construction of Unitized Aluminum Curtain Wall
author_sort I-Ting You
title A Study on Fire-Resistive Construction of Unitized Aluminum Curtain Wall
title_short A Study on Fire-Resistive Construction of Unitized Aluminum Curtain Wall
title_full A Study on Fire-Resistive Construction of Unitized Aluminum Curtain Wall
title_fullStr A Study on Fire-Resistive Construction of Unitized Aluminum Curtain Wall
title_full_unstemmed A Study on Fire-Resistive Construction of Unitized Aluminum Curtain Wall
title_sort study on fire-resistive construction of unitized aluminum curtain wall
publishDate 2003
url http://ndltd.ncl.edu.tw/handle/14701482625265335744
work_keys_str_mv AT itingyou astudyonfireresistiveconstructionofunitizedaluminumcurtainwall
AT yóuyītíng astudyonfireresistiveconstructionofunitizedaluminumcurtainwall
AT itingyou dānyuánshìlǚwéimùqiángfánghuǒgòufǎzhīyánjiū
AT yóuyītíng dānyuánshìlǚwéimùqiángfánghuǒgòufǎzhīyánjiū
AT itingyou studyonfireresistiveconstructionofunitizedaluminumcurtainwall
AT yóuyītíng studyonfireresistiveconstructionofunitizedaluminumcurtainwall
_version_ 1717780186445905920