A Study on Fire-Resistive Construction of Unitized Aluminum Curtain Wall
碩士 === 國立成功大學 === 建築學系碩博士班 === 91 === Generally speaking, the “curtain wall fire performance” test is based on the CNS 12514 (Method of fire resistance test for structural parts of building); however, as a matter of fact, people don’t test it through this standard method when confirming the function...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | zh-TW |
Published: |
2003
|
Online Access: | http://ndltd.ncl.edu.tw/handle/14701482625265335744 |
id |
ndltd-TW-091NCKU5222025 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-091NCKU52220252015-10-13T17:07:02Z http://ndltd.ncl.edu.tw/handle/14701482625265335744 A Study on Fire-Resistive Construction of Unitized Aluminum Curtain Wall 單元式鋁帷幕牆防火構法之研究 I-Ting You 游依婷 碩士 國立成功大學 建築學系碩博士班 91 Generally speaking, the “curtain wall fire performance” test is based on the CNS 12514 (Method of fire resistance test for structural parts of building); however, as a matter of fact, people don’t test it through this standard method when confirming the function of “curtain wall fire performance”. People don’t judge the fire performance by considering that the fire performance of the whole wall system could be the weakest point of preventing fire spread, but judge the “curtain wall fire performance” by the fire incombustibility of the constructed material of curtain wall. Especially, the fire performance of the common-used Unitized Aluminum Curtain Wall is quite controversial for the essence of the constructed material. Considering about the fact, this study attempts to clarify the relationship between the fire behavior in the buildings and the wall, to figure out the construction forms of domestic Unitized Aluminum Curtain Wall by reviewing studies and conveying the companies and experts, and to give some suggestions and problems exploring of Fire-Resistive Construction of Unitized Aluminum Curtain Wall by using the researches of buildings fire behavior. As it occurred that the relating background information is not enough for this Fire-Resistive Construction due to the domestic preliminary study level of the fire performance of curtain wall, this study also attempt to inform what is insufficient for supervising the related aspects and following researches while explore the problems and possible strategies. Bin Huang 黃斌 2003 學位論文 ; thesis 86 zh-TW |
collection |
NDLTD |
language |
zh-TW |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 國立成功大學 === 建築學系碩博士班 === 91 === Generally speaking, the “curtain wall fire performance” test is based on the CNS 12514 (Method of fire resistance test for structural parts of building); however, as a matter of fact, people don’t test it through this standard method when confirming the function of “curtain wall fire performance”. People don’t judge the fire performance by considering that the fire performance of the whole wall system could be the weakest point of preventing fire spread, but judge the “curtain wall fire performance” by the fire incombustibility of the constructed material of curtain wall. Especially, the fire performance of the common-used Unitized Aluminum Curtain Wall is quite controversial for the essence of the constructed material.
Considering about the fact, this study attempts to clarify the relationship between the fire behavior in the buildings and the wall, to figure out the construction forms of domestic Unitized Aluminum Curtain Wall by reviewing studies and conveying the companies and experts, and to give some suggestions and problems exploring of Fire-Resistive Construction of Unitized Aluminum Curtain Wall by using the researches of buildings fire behavior.
As it occurred that the relating background information is not enough for this Fire-Resistive Construction due to the domestic preliminary study level of the fire performance of curtain wall, this study also attempt to inform what is insufficient for supervising the related aspects and following researches while explore the problems and possible strategies.
|
author2 |
Bin Huang |
author_facet |
Bin Huang I-Ting You 游依婷 |
author |
I-Ting You 游依婷 |
spellingShingle |
I-Ting You 游依婷 A Study on Fire-Resistive Construction of Unitized Aluminum Curtain Wall |
author_sort |
I-Ting You |
title |
A Study on Fire-Resistive Construction of Unitized Aluminum Curtain Wall |
title_short |
A Study on Fire-Resistive Construction of Unitized Aluminum Curtain Wall |
title_full |
A Study on Fire-Resistive Construction of Unitized Aluminum Curtain Wall |
title_fullStr |
A Study on Fire-Resistive Construction of Unitized Aluminum Curtain Wall |
title_full_unstemmed |
A Study on Fire-Resistive Construction of Unitized Aluminum Curtain Wall |
title_sort |
study on fire-resistive construction of unitized aluminum curtain wall |
publishDate |
2003 |
url |
http://ndltd.ncl.edu.tw/handle/14701482625265335744 |
work_keys_str_mv |
AT itingyou astudyonfireresistiveconstructionofunitizedaluminumcurtainwall AT yóuyītíng astudyonfireresistiveconstructionofunitizedaluminumcurtainwall AT itingyou dānyuánshìlǚwéimùqiángfánghuǒgòufǎzhīyánjiū AT yóuyītíng dānyuánshìlǚwéimùqiángfánghuǒgòufǎzhīyánjiū AT itingyou studyonfireresistiveconstructionofunitizedaluminumcurtainwall AT yóuyītíng studyonfireresistiveconstructionofunitizedaluminumcurtainwall |
_version_ |
1717780186445905920 |