Impact of Harmonics upon the Low Energy Overcurrent Relays

碩士 === 中原大學 === 電機工程研究所 === 91 === Abstract  Due to the wide use of nonlinear loads, there are many serious problems of harmonics in the power system. It may cause voltage distortion, power quality degradation and protective relays malfunction. Therefore, the effect analysis of harmonics on the pro...

Full description

Bibliographic Details
Main Authors: Cheng-Yu Huang, 黃建裕
Other Authors: Ying-Yi Hong
Format: Others
Language:zh-TW
Published: 2003
Online Access:http://ndltd.ncl.edu.tw/handle/7ha2x9
id ndltd-TW-091CYCU5442049
record_format oai_dc
spelling ndltd-TW-091CYCU54420492018-06-25T06:06:26Z http://ndltd.ncl.edu.tw/handle/7ha2x9 Impact of Harmonics upon the Low Energy Overcurrent Relays 諧波對小能量過電流電驛的影響 Cheng-Yu Huang 黃建裕 碩士 中原大學 電機工程研究所 91 Abstract  Due to the wide use of nonlinear loads, there are many serious problems of harmonics in the power system. It may cause voltage distortion, power quality degradation and protective relays malfunction. Therefore, the effect analysis of harmonics on the protective relays is necessary. In order to made the protective relays function properly under harmonic effects, this paper examines the small-energy overcurrent relay characteristics using experiment. Based upon the measurement results, some suggestions for improvement on relay setting are proposed. The test results may provide a valuable reference in applying and designing on protective schemes of relays. Ying-Yi Hong 洪穎怡 2003 學位論文 ; thesis 75 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 中原大學 === 電機工程研究所 === 91 === Abstract  Due to the wide use of nonlinear loads, there are many serious problems of harmonics in the power system. It may cause voltage distortion, power quality degradation and protective relays malfunction. Therefore, the effect analysis of harmonics on the protective relays is necessary. In order to made the protective relays function properly under harmonic effects, this paper examines the small-energy overcurrent relay characteristics using experiment. Based upon the measurement results, some suggestions for improvement on relay setting are proposed. The test results may provide a valuable reference in applying and designing on protective schemes of relays.
author2 Ying-Yi Hong
author_facet Ying-Yi Hong
Cheng-Yu Huang
黃建裕
author Cheng-Yu Huang
黃建裕
spellingShingle Cheng-Yu Huang
黃建裕
Impact of Harmonics upon the Low Energy Overcurrent Relays
author_sort Cheng-Yu Huang
title Impact of Harmonics upon the Low Energy Overcurrent Relays
title_short Impact of Harmonics upon the Low Energy Overcurrent Relays
title_full Impact of Harmonics upon the Low Energy Overcurrent Relays
title_fullStr Impact of Harmonics upon the Low Energy Overcurrent Relays
title_full_unstemmed Impact of Harmonics upon the Low Energy Overcurrent Relays
title_sort impact of harmonics upon the low energy overcurrent relays
publishDate 2003
url http://ndltd.ncl.edu.tw/handle/7ha2x9
work_keys_str_mv AT chengyuhuang impactofharmonicsuponthelowenergyovercurrentrelays
AT huángjiànyù impactofharmonicsuponthelowenergyovercurrentrelays
AT chengyuhuang xiébōduìxiǎonéngliàngguòdiànliúdiànyìdeyǐngxiǎng
AT huángjiànyù xiébōduìxiǎonéngliàngguòdiànliúdiànyìdeyǐngxiǎng
_version_ 1718706057466871808