The Effect Analysis and Simulation Test of Harmonics on Differential Protection for Scott Transformers

碩士 === 中原大學 === 電機工程研究所 === 91 === All of the High Speed Railway (HSR) systems around the world used single phase voltage to the trains, and adopted three-phase to two-phase special transformer to supply electric power. Due to the large variations of electric power when starting and braking the trai...

Full description

Bibliographic Details
Main Authors: Hsiang-Peng Hsu, 徐享鵬
Other Authors: Jin-Maun Ho
Format: Others
Language:zh-TW
Published: 2003
Online Access:http://ndltd.ncl.edu.tw/handle/cuuxw7
id ndltd-TW-091CYCU5442043
record_format oai_dc
spelling ndltd-TW-091CYCU54420432018-06-25T06:06:26Z http://ndltd.ncl.edu.tw/handle/cuuxw7 The Effect Analysis and Simulation Test of Harmonics on Differential Protection for Scott Transformers 諧波對史考特變壓器差動保護的影響分析與模擬測試 Hsiang-Peng Hsu 徐享鵬 碩士 中原大學 電機工程研究所 91 All of the High Speed Railway (HSR) systems around the world used single phase voltage to the trains, and adopted three-phase to two-phase special transformer to supply electric power. Due to the large variations of electric power when starting and braking the trains, there arises a lot of harmonics in the motor-driven system. And the nonlinear loads may cause a lot of harmonic, too. Scott transformer has a special wiring structure, it’s major purpose is to transfer a three-phase power source into a balance two-phase or two single phase power source for supplying special single plase loads. The research aims at the effects of harmonic to differential protecting relay of Scott transformer. The CA type differential relay is used to protect the Scott transformer. The instrument, ELGAR Smart Wave SW5250, is used to generate for the different waveforms this experiment. We hope the results can be a valuable reference for protection design for Scott transformer. Jin-Maun Ho 何金滿 2003 學位論文 ; thesis 117 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 中原大學 === 電機工程研究所 === 91 === All of the High Speed Railway (HSR) systems around the world used single phase voltage to the trains, and adopted three-phase to two-phase special transformer to supply electric power. Due to the large variations of electric power when starting and braking the trains, there arises a lot of harmonics in the motor-driven system. And the nonlinear loads may cause a lot of harmonic, too. Scott transformer has a special wiring structure, it’s major purpose is to transfer a three-phase power source into a balance two-phase or two single phase power source for supplying special single plase loads. The research aims at the effects of harmonic to differential protecting relay of Scott transformer. The CA type differential relay is used to protect the Scott transformer. The instrument, ELGAR Smart Wave SW5250, is used to generate for the different waveforms this experiment. We hope the results can be a valuable reference for protection design for Scott transformer.
author2 Jin-Maun Ho
author_facet Jin-Maun Ho
Hsiang-Peng Hsu
徐享鵬
author Hsiang-Peng Hsu
徐享鵬
spellingShingle Hsiang-Peng Hsu
徐享鵬
The Effect Analysis and Simulation Test of Harmonics on Differential Protection for Scott Transformers
author_sort Hsiang-Peng Hsu
title The Effect Analysis and Simulation Test of Harmonics on Differential Protection for Scott Transformers
title_short The Effect Analysis and Simulation Test of Harmonics on Differential Protection for Scott Transformers
title_full The Effect Analysis and Simulation Test of Harmonics on Differential Protection for Scott Transformers
title_fullStr The Effect Analysis and Simulation Test of Harmonics on Differential Protection for Scott Transformers
title_full_unstemmed The Effect Analysis and Simulation Test of Harmonics on Differential Protection for Scott Transformers
title_sort effect analysis and simulation test of harmonics on differential protection for scott transformers
publishDate 2003
url http://ndltd.ncl.edu.tw/handle/cuuxw7
work_keys_str_mv AT hsiangpenghsu theeffectanalysisandsimulationtestofharmonicsondifferentialprotectionforscotttransformers
AT xúxiǎngpéng theeffectanalysisandsimulationtestofharmonicsondifferentialprotectionforscotttransformers
AT hsiangpenghsu xiébōduìshǐkǎotèbiànyāqìchàdòngbǎohùdeyǐngxiǎngfēnxīyǔmónǐcèshì
AT xúxiǎngpéng xiébōduìshǐkǎotèbiànyāqìchàdòngbǎohùdeyǐngxiǎngfēnxīyǔmónǐcèshì
AT hsiangpenghsu effectanalysisandsimulationtestofharmonicsondifferentialprotectionforscotttransformers
AT xúxiǎngpéng effectanalysisandsimulationtestofharmonicsondifferentialprotectionforscotttransformers
_version_ 1718706053716115456