THE DESIGN OF HEAT SINK WITH RING-TYPE FLOW CHANNEL
碩士 === 中華大學 === 機械與航太工程研究所 === 91 === The present heat sink of most heat sink are rectangular shapes. Fins become parallel or irradiative arrays, extruded from the surface of substrate. The flow of forced convective fan is from the top surface coming, no flow blow out from hub of fan, res...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | zh-TW |
Published: |
2003
|
Online Access: | http://ndltd.ncl.edu.tw/handle/57341791499777216122 |
id |
ndltd-TW-091CHPI0598019 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-091CHPI05980192016-06-24T04:16:12Z http://ndltd.ncl.edu.tw/handle/57341791499777216122 THE DESIGN OF HEAT SINK WITH RING-TYPE FLOW CHANNEL 環形流道散熱器設計 Wei Kuo Han 韓偉國 碩士 中華大學 機械與航太工程研究所 91 The present heat sink of most heat sink are rectangular shapes. Fins become parallel or irradiative arrays, extruded from the surface of substrate. The flow of forced convective fan is from the top surface coming, no flow blow out from hub of fan, results in stagnation region flow at center of heat sink , and lower the efficiency of heat transfer rate. In order to innovating from the traditional rectangular shapes, the ring shapes flow passage fins are designed. The geometry between fins and substrate becomes more streamline, and the flow becomes secondary flow and vortex structure. The higher heat transfer rate will be expected. This paper run the Star-CD code to help and audit design. Compare with sample measuring temperature. To understand the design weighting of heat conduction and heat convection. Major factor is flow resistance of supplied pressure and flow in heat sink , and flow over a fin surface near heat source. The faster flow near heat source the more efficiency of heat transfer rate. The more heat conductive volume the less heat convective surface under same volume of heat sink. In this study, the cross section of the flow channel ratio between ring-type and rectangular-type is 8.5 : 21.5 cm2 . Relative pressure drop ratio is 42.3 : 29.2 Pa and flow pass through the channel is 0.151 : 0.472 m3/min after run Star-CD. The average velocity ratio is 2.97 :3.77 m/s . Finally, compare with temperature at the center of heat source is 68.0 : 53.5℃. Consequent, Under forced convective cooling, heat convection is dominant with aluminium alloy material. Bor Jang Tsai 蔡博章 2003 學位論文 ; thesis 87 zh-TW |
collection |
NDLTD |
language |
zh-TW |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 中華大學 === 機械與航太工程研究所 === 91 === The present heat sink of most heat sink are rectangular shapes. Fins become parallel or irradiative arrays, extruded from the surface of substrate. The flow of forced convective fan is from the top surface coming, no flow blow out from hub of fan, results in stagnation region flow at center of heat sink , and lower the efficiency of heat transfer rate. In order to innovating from the traditional rectangular shapes, the ring shapes flow passage fins are designed. The geometry between fins and substrate becomes more streamline, and the flow becomes secondary flow and vortex structure. The higher heat transfer rate will be expected. This paper run the Star-CD code to help and audit design. Compare with sample measuring temperature. To understand the design weighting of heat conduction and heat convection. Major factor is flow resistance of supplied pressure and flow in heat sink , and flow over a fin surface near heat source. The faster flow near heat source the more efficiency of heat transfer rate.
The more heat conductive volume the less heat convective surface under same volume of heat sink. In this study, the cross section of the flow channel ratio between ring-type and rectangular-type is 8.5 : 21.5 cm2 . Relative pressure drop ratio is 42.3 : 29.2 Pa and flow pass through the channel is 0.151 : 0.472 m3/min after run Star-CD. The average velocity ratio is 2.97 :3.77 m/s . Finally, compare with temperature at the center of heat source is 68.0 : 53.5℃. Consequent, Under forced convective cooling, heat convection is dominant with aluminium alloy material.
|
author2 |
Bor Jang Tsai |
author_facet |
Bor Jang Tsai Wei Kuo Han 韓偉國 |
author |
Wei Kuo Han 韓偉國 |
spellingShingle |
Wei Kuo Han 韓偉國 THE DESIGN OF HEAT SINK WITH RING-TYPE FLOW CHANNEL |
author_sort |
Wei Kuo Han |
title |
THE DESIGN OF HEAT SINK WITH RING-TYPE FLOW CHANNEL |
title_short |
THE DESIGN OF HEAT SINK WITH RING-TYPE FLOW CHANNEL |
title_full |
THE DESIGN OF HEAT SINK WITH RING-TYPE FLOW CHANNEL |
title_fullStr |
THE DESIGN OF HEAT SINK WITH RING-TYPE FLOW CHANNEL |
title_full_unstemmed |
THE DESIGN OF HEAT SINK WITH RING-TYPE FLOW CHANNEL |
title_sort |
design of heat sink with ring-type flow channel |
publishDate |
2003 |
url |
http://ndltd.ncl.edu.tw/handle/57341791499777216122 |
work_keys_str_mv |
AT weikuohan thedesignofheatsinkwithringtypeflowchannel AT hánwěiguó thedesignofheatsinkwithringtypeflowchannel AT weikuohan huánxíngliúdàosànrèqìshèjì AT hánwěiguó huánxíngliúdàosànrèqìshèjì AT weikuohan designofheatsinkwithringtypeflowchannel AT hánwěiguó designofheatsinkwithringtypeflowchannel |
_version_ |
1718323508369424384 |