The Study of Ventilation and Energy Recovery for Isolation Rooms

碩士 === 國立臺北科技大學 === 冷凍與低溫科技研究所 === 90 === In health care facilities, Air conditioning and ventilation system is a factor in the Prevention and Treatment of Disease ,not just a role of comfort, such as Mycobacterium tuberculosis are highly infectious and transported within air,the patient is the sour...

Full description

Bibliographic Details
Main Authors: LIN CHEN HUA, 林振華
Other Authors: 李文興
Format: Others
Language:zh-TW
Published: 2002
Online Access:http://ndltd.ncl.edu.tw/handle/28539328871103129992
id ndltd-TW-090TIT00703037
record_format oai_dc
spelling ndltd-TW-090TIT007030372016-06-24T04:14:43Z http://ndltd.ncl.edu.tw/handle/28539328871103129992 The Study of Ventilation and Energy Recovery for Isolation Rooms 呼吸道傳染隔離病房通風換氣需求與系統節能之探討 LIN CHEN HUA 林振華 碩士 國立臺北科技大學 冷凍與低溫科技研究所 90 In health care facilities, Air conditioning and ventilation system is a factor in the Prevention and Treatment of Disease ,not just a role of comfort, such as Mycobacterium tuberculosis are highly infectious and transported within air,the patient is the source of contamination ,Infectious isolation room keep Negative pressure to protect health care worker(HCW)and others from infectious patients, a positive pressure should be maintained in protective isolation rooms, if the patient is immunosuppressed persons(including bone marrow or organ transplant, leukemia, burn, and AIDS patients). Ventilation is important in control contaminant concentrations, and nosocomial infection , High air exchange rates are used to pressurize the space and remove contaminants to protect patients, Many health care-related ventilation standards are based on ACH(Air changes per hour),CDC and ASHRAE are using,but the ACH standard provides less air to small spaces and more air to large spaces, is unlikely to be related to the amount of contaminant generated, a different ventilation standard, airflow L/s•person(Liter per second per person)may be more indicative of expected contamination levels if the source of the contamination is related more to the occupants of the space, this research has conducted for isolation rooms, and discussion the variation of two ventilation standards with different droplet nuclei contamination concentration in isolation rooms. By means of a HEPA filter should also be used, exhaust air is directed through heat-recovery devices, to reduce the costs of operating ventilation systems, this study evaluate the potential of energy saving and rate of return on investment, the further detail study will form an basis of reasonable ventilation rate and annual energy consumption per square meter floor of isolation rooms. 李文興 2002 學位論文 ; thesis 93 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立臺北科技大學 === 冷凍與低溫科技研究所 === 90 === In health care facilities, Air conditioning and ventilation system is a factor in the Prevention and Treatment of Disease ,not just a role of comfort, such as Mycobacterium tuberculosis are highly infectious and transported within air,the patient is the source of contamination ,Infectious isolation room keep Negative pressure to protect health care worker(HCW)and others from infectious patients, a positive pressure should be maintained in protective isolation rooms, if the patient is immunosuppressed persons(including bone marrow or organ transplant, leukemia, burn, and AIDS patients). Ventilation is important in control contaminant concentrations, and nosocomial infection , High air exchange rates are used to pressurize the space and remove contaminants to protect patients, Many health care-related ventilation standards are based on ACH(Air changes per hour),CDC and ASHRAE are using,but the ACH standard provides less air to small spaces and more air to large spaces, is unlikely to be related to the amount of contaminant generated, a different ventilation standard, airflow L/s•person(Liter per second per person)may be more indicative of expected contamination levels if the source of the contamination is related more to the occupants of the space, this research has conducted for isolation rooms, and discussion the variation of two ventilation standards with different droplet nuclei contamination concentration in isolation rooms. By means of a HEPA filter should also be used, exhaust air is directed through heat-recovery devices, to reduce the costs of operating ventilation systems, this study evaluate the potential of energy saving and rate of return on investment, the further detail study will form an basis of reasonable ventilation rate and annual energy consumption per square meter floor of isolation rooms.
author2 李文興
author_facet 李文興
LIN CHEN HUA
林振華
author LIN CHEN HUA
林振華
spellingShingle LIN CHEN HUA
林振華
The Study of Ventilation and Energy Recovery for Isolation Rooms
author_sort LIN CHEN HUA
title The Study of Ventilation and Energy Recovery for Isolation Rooms
title_short The Study of Ventilation and Energy Recovery for Isolation Rooms
title_full The Study of Ventilation and Energy Recovery for Isolation Rooms
title_fullStr The Study of Ventilation and Energy Recovery for Isolation Rooms
title_full_unstemmed The Study of Ventilation and Energy Recovery for Isolation Rooms
title_sort study of ventilation and energy recovery for isolation rooms
publishDate 2002
url http://ndltd.ncl.edu.tw/handle/28539328871103129992
work_keys_str_mv AT linchenhua thestudyofventilationandenergyrecoveryforisolationrooms
AT línzhènhuá thestudyofventilationandenergyrecoveryforisolationrooms
AT linchenhua hūxīdàochuánrǎngélíbìngfángtōngfēnghuànqìxūqiúyǔxìtǒngjiénéngzhītàntǎo
AT línzhènhuá hūxīdàochuánrǎngélíbìngfángtōngfēnghuànqìxūqiúyǔxìtǒngjiénéngzhītàntǎo
AT linchenhua studyofventilationandenergyrecoveryforisolationrooms
AT línzhènhuá studyofventilationandenergyrecoveryforisolationrooms
_version_ 1718320818835947520