The Design, Manufacture and Performance Test of Capillary Structure in a Loop Heat Pipe

碩士 === 國立臺灣大學 === 機械工程學研究所 === 90 === The present effort seeks to investigate the effects of the capillary structure parameters by manufacturing a loop heat pipe, which has a heat transfer capacity of about 300W. First, a loop heat pipe is designed through the theoretical analysis. Furthermore, the...

Full description

Bibliographic Details
Main Authors: Tian-Ming Wang, 王添銘
Other Authors: Yau-Ming Chen
Format: Others
Language:zh-TW
Published: 2002
Online Access:http://ndltd.ncl.edu.tw/handle/71816758275012460819