none

碩士 === 國立中央大學 === 土木工程學系碩士在職專班 === 90 === At present in water-supply areas, as for the supply nets of piped water, there are still plenty of problems on operation, maintenance, and administration, including water pressure, water quantity, and water quality. While the supply nets of water lack of wa...

Full description

Bibliographic Details
Main Authors: Shae-Zan Yuan, 袁覺仁
Other Authors: none
Format: Others
Language:zh-TW
Published: 2002
Online Access:http://ndltd.ncl.edu.tw/handle/69486029674600505737
id ndltd-TW-090NCU05015081
record_format oai_dc
spelling ndltd-TW-090NCU050150812015-10-13T12:46:50Z http://ndltd.ncl.edu.tw/handle/69486029674600505737 none 配水管網破管與供水穩定性關係之研究 Shae-Zan Yuan 袁覺仁 碩士 國立中央大學 土木工程學系碩士在職專班 90 At present in water-supply areas, as for the supply nets of piped water, there are still plenty of problems on operation, maintenance, and administration, including water pressure, water quantity, and water quality. While the supply nets of water lack of water to provide, or the broken pipes and other causes lead water supply unbalanced, which will show the importance of the water-control devices ─like water bolts and water-supply operation. In case there are too many such bolts, the cost of the construction and the manpower of administration will surely increase uselessly. In other respects, should the water-control bolts are deployed deficiently, many water bolts must be switched off as the pipes are broken and need to be repaired in time. If the bolt is installed in the wrong place, the broken pipe will cause the water supply unbalance. When the system of the supply-water pipes leaking, the water pressure will be low in the water-supply area, the quantity of water supply will reduce, and the quality of water will be also polluted. In the period of switching off the broken pipes, the neighboring water bolts are waiting to be repaired in order to supply water. During the recondition of water supply, the flow and the direction of each pipe section, and surplus water ends of each joint will face unbalanced condition. Probably it will make the water pressure of the joints lower. Then the proper water pressure could not be satisfied (1.5~4.0kg/ cm2) when providing the customers running water. The study uses Hardy Cross method to analyze each section when pipes are broken. Through installing the water-control bolts, increasing or decreasing the volume of water supply, increasing or decreasing the areas of water supply, dividing the districts and times of water supply, and probing various angles to analyze the matter, an engineer can improve the balance of water supply more precisely. This study bases on the water supply of Yu-shih district, through analyses and synthetic arrangements; we propose the improvement plans which provide the references for how to install water-control bolts and how to maintain and administrate water supply for the future is proposed. In addition, by applying flow meters , piezo-meters, and the center of monitor, which will facilitate to switch off bolts in case of any broken pipes, so it may shorten the repairing time for water supply and maintain water supply steadily during the period of fixing. none 吳瑞賢 2002 學位論文 ; thesis 148 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立中央大學 === 土木工程學系碩士在職專班 === 90 === At present in water-supply areas, as for the supply nets of piped water, there are still plenty of problems on operation, maintenance, and administration, including water pressure, water quantity, and water quality. While the supply nets of water lack of water to provide, or the broken pipes and other causes lead water supply unbalanced, which will show the importance of the water-control devices ─like water bolts and water-supply operation. In case there are too many such bolts, the cost of the construction and the manpower of administration will surely increase uselessly. In other respects, should the water-control bolts are deployed deficiently, many water bolts must be switched off as the pipes are broken and need to be repaired in time. If the bolt is installed in the wrong place, the broken pipe will cause the water supply unbalance. When the system of the supply-water pipes leaking, the water pressure will be low in the water-supply area, the quantity of water supply will reduce, and the quality of water will be also polluted. In the period of switching off the broken pipes, the neighboring water bolts are waiting to be repaired in order to supply water. During the recondition of water supply, the flow and the direction of each pipe section, and surplus water ends of each joint will face unbalanced condition. Probably it will make the water pressure of the joints lower. Then the proper water pressure could not be satisfied (1.5~4.0kg/ cm2) when providing the customers running water. The study uses Hardy Cross method to analyze each section when pipes are broken. Through installing the water-control bolts, increasing or decreasing the volume of water supply, increasing or decreasing the areas of water supply, dividing the districts and times of water supply, and probing various angles to analyze the matter, an engineer can improve the balance of water supply more precisely. This study bases on the water supply of Yu-shih district, through analyses and synthetic arrangements; we propose the improvement plans which provide the references for how to install water-control bolts and how to maintain and administrate water supply for the future is proposed. In addition, by applying flow meters , piezo-meters, and the center of monitor, which will facilitate to switch off bolts in case of any broken pipes, so it may shorten the repairing time for water supply and maintain water supply steadily during the period of fixing.
author2 none
author_facet none
Shae-Zan Yuan
袁覺仁
author Shae-Zan Yuan
袁覺仁
spellingShingle Shae-Zan Yuan
袁覺仁
none
author_sort Shae-Zan Yuan
title none
title_short none
title_full none
title_fullStr none
title_full_unstemmed none
title_sort none
publishDate 2002
url http://ndltd.ncl.edu.tw/handle/69486029674600505737
work_keys_str_mv AT shaezanyuan none
AT yuánjuérén none
AT shaezanyuan pèishuǐguǎnwǎngpòguǎnyǔgōngshuǐwěndìngxìngguānxìzhīyánjiū
AT yuánjuérén pèishuǐguǎnwǎngpòguǎnyǔgōngshuǐwěndìngxìngguānxìzhīyánjiū
_version_ 1716865484924649472