Design of Power Transmitter for PW Doppler Ultrasound System

碩士 === 國立成功大學 === 醫學工程研究所碩博士班 === 90 === Abstract The viscoelastic properties are critical to specific function for each living organ and fundamental in biomechanical modeling of tissue behavior. Currently invasive methods are often used to measure biomechanical properties in vitro, which are deviat...

Full description

Bibliographic Details
Main Authors: Meng-Hua Yan, 顏孟華
Other Authors: Kao-Chi Chung
Format: Others
Language:zh-TW
Published: 2002
Online Access:http://ndltd.ncl.edu.tw/handle/69z32w
id ndltd-TW-090NCKU5530024
record_format oai_dc
spelling ndltd-TW-090NCKU55300242018-06-25T06:05:29Z http://ndltd.ncl.edu.tw/handle/69z32w Design of Power Transmitter for PW Doppler Ultrasound System 激發放大器設計與應用於脈波式杜卜勒超音波系統 Meng-Hua Yan 顏孟華 碩士 國立成功大學 醫學工程研究所碩博士班 90 Abstract The viscoelastic properties are critical to specific function for each living organ and fundamental in biomechanical modeling of tissue behavior. Currently invasive methods are often used to measure biomechanical properties in vitro, which are deviated from those in living status and difficult to be applied in practice. During the last decade, sonoelasticity has being studied by the Doppler ultrasonic technology with low frequency tissue vibration. It seems to be prospective in developing non-invasive, in vivo measuring technology for viscoelasticity. The RF power amplifier, which is high frequency, power output and cost, is improperly applied to excite the ultrasonic transducers (UTS) with frequency at MHz order. The purpose of this research is to design a power transmitter system specified for a pulsed Doppler ultrasonic measuring system. The system design consists of interface control (IC), burst signal generator (BSG), power amplifier (PA) and isolated limiter (IL) modules. The IC unit is developed for signal frequency, pulse repetitive frequency and number setting. The BSG is to generate pre-stage excited signal for the UTS, according to the setup from IC unit. Then the PA is designed for output voltage and power amplification to directly excite the UTS. The IL circuit design is used diodes to isolate the input transmitting signal to and the reflective signal from the UTS. The prototyped power transmitter system has been developed completely with system component calibration. The IC unit has provided functions with keyboard input, LCDM display, PRF signal generation and output relay control. The PA provides maximally output signal of 270VP-P with 3.5, 5 and 7.5 MHz to excite the UTS. The calibration results show that there is signal distortion appearing in the forward and backward parts of each PRF signal. An improved method is to look into better IC component. The calibration of whole system indicates that the output standard error of central frequencies of 3.5, 5 and 7.5 MHz is within 0.1 MHz range. The results also show that maximal SNR (signal to noise ratio) is 53dB with minimal at 26dB. The system SNR is expected to be improved by circuit design. The future system research and development are recommended as following: (1) improved BSG design to provide adjustable frequency setting; (2) to implement the system in the pulsed Doppler ultrasonic measuring system (replace the conventional RF power amplifier) to non-invasive, in vivo measuring for soft tissue’ viscoelasticity; and (3) to expand system design and development for the application of conventional ultrasonic instrumentation. Kao-Chi Chung 鍾高基 2002 學位論文 ; thesis 105 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立成功大學 === 醫學工程研究所碩博士班 === 90 === Abstract The viscoelastic properties are critical to specific function for each living organ and fundamental in biomechanical modeling of tissue behavior. Currently invasive methods are often used to measure biomechanical properties in vitro, which are deviated from those in living status and difficult to be applied in practice. During the last decade, sonoelasticity has being studied by the Doppler ultrasonic technology with low frequency tissue vibration. It seems to be prospective in developing non-invasive, in vivo measuring technology for viscoelasticity. The RF power amplifier, which is high frequency, power output and cost, is improperly applied to excite the ultrasonic transducers (UTS) with frequency at MHz order. The purpose of this research is to design a power transmitter system specified for a pulsed Doppler ultrasonic measuring system. The system design consists of interface control (IC), burst signal generator (BSG), power amplifier (PA) and isolated limiter (IL) modules. The IC unit is developed for signal frequency, pulse repetitive frequency and number setting. The BSG is to generate pre-stage excited signal for the UTS, according to the setup from IC unit. Then the PA is designed for output voltage and power amplification to directly excite the UTS. The IL circuit design is used diodes to isolate the input transmitting signal to and the reflective signal from the UTS. The prototyped power transmitter system has been developed completely with system component calibration. The IC unit has provided functions with keyboard input, LCDM display, PRF signal generation and output relay control. The PA provides maximally output signal of 270VP-P with 3.5, 5 and 7.5 MHz to excite the UTS. The calibration results show that there is signal distortion appearing in the forward and backward parts of each PRF signal. An improved method is to look into better IC component. The calibration of whole system indicates that the output standard error of central frequencies of 3.5, 5 and 7.5 MHz is within 0.1 MHz range. The results also show that maximal SNR (signal to noise ratio) is 53dB with minimal at 26dB. The system SNR is expected to be improved by circuit design. The future system research and development are recommended as following: (1) improved BSG design to provide adjustable frequency setting; (2) to implement the system in the pulsed Doppler ultrasonic measuring system (replace the conventional RF power amplifier) to non-invasive, in vivo measuring for soft tissue’ viscoelasticity; and (3) to expand system design and development for the application of conventional ultrasonic instrumentation.
author2 Kao-Chi Chung
author_facet Kao-Chi Chung
Meng-Hua Yan
顏孟華
author Meng-Hua Yan
顏孟華
spellingShingle Meng-Hua Yan
顏孟華
Design of Power Transmitter for PW Doppler Ultrasound System
author_sort Meng-Hua Yan
title Design of Power Transmitter for PW Doppler Ultrasound System
title_short Design of Power Transmitter for PW Doppler Ultrasound System
title_full Design of Power Transmitter for PW Doppler Ultrasound System
title_fullStr Design of Power Transmitter for PW Doppler Ultrasound System
title_full_unstemmed Design of Power Transmitter for PW Doppler Ultrasound System
title_sort design of power transmitter for pw doppler ultrasound system
publishDate 2002
url http://ndltd.ncl.edu.tw/handle/69z32w
work_keys_str_mv AT menghuayan designofpowertransmitterforpwdopplerultrasoundsystem
AT yánmènghuá designofpowertransmitterforpwdopplerultrasoundsystem
AT menghuayan jīfāfàngdàqìshèjìyǔyīngyòngyúmàibōshìdùbolēichāoyīnbōxìtǒng
AT yánmènghuá jīfāfàngdàqìshèjìyǔyīngyòngyúmàibōshìdùbolēichāoyīnbōxìtǒng
_version_ 1718704444442411008