Application of Fuzzy Control Theory and Taguchi Methods to Boiler Automatic Combustion Control of Cogeneration Plant
碩士 === 國立成功大學 === 電機工程學系碩博士班 === 90 === Application of Fuzzy Control Theory and Taguchi Methods to Boiler Automatic Combustion Control of Cogeneration Plant Guo-shyong Yang* Ming-Shing Young** Department of Electrical Engineering National Cheng Kung University , Tainan , Taiwan , R.O.C Abstract Thi...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | zh-TW |
Published: |
2002
|
Online Access: | http://ndltd.ncl.edu.tw/handle/20074582688081424457 |
id |
ndltd-TW-090NCKU5442170 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-090NCKU54421702016-06-08T04:14:02Z http://ndltd.ncl.edu.tw/handle/20074582688081424457 Application of Fuzzy Control Theory and Taguchi Methods to Boiler Automatic Combustion Control of Cogeneration Plant 應用模糊控制理論與田口方法於汽電共生廠鍋爐自動燃燒控制之研究 Guo-Shyong Yang 楊國雄 碩士 國立成功大學 電機工程學系碩博士班 90 Application of Fuzzy Control Theory and Taguchi Methods to Boiler Automatic Combustion Control of Cogeneration Plant Guo-shyong Yang* Ming-Shing Young** Department of Electrical Engineering National Cheng Kung University , Tainan , Taiwan , R.O.C Abstract This thesis is mainly explore that the application of fuzzy control on the boiler Automatic Combustion Control (ACC) of the cogeneration plant. As the boiler combustion system is a non-linear system and the quality of system will be various with the changes of time. Hence, it is often essential for operator to adjust anew the control parameters of PID to adapt variation in the quality of system. Contrary, it is not necessary for a fuzzy control. Therefore, we can get a better control effect. This research is to take aim on the Boiler Automatic Combustion of the cogeneration plant, which in nature is a complex system of non-linear and time-delay of combustion. We employed the fuzzy control theory for the design of the fuzzy controller and for the comparison of control efficacy between PID control and fuzzy control under the transfer function model of the boiler combustion system with different combustion time-delay. Moreover, for the design of the fuzzy controller, the membership function that designer choose may not always be the best combination of membership function parameters. Therefore, in this study, we introduced the Taguchi Quality Experiment Method, which through the way of Orthogonal Array experiment, we solved for a set of best parameters combination for input variable membership function enabling higher level of fuzzy control efficiencies. In the final section of the thesis, coordinating actual Automatic Combustion Control operation with fuzzy control theory, we then proceeded with the fuzzy controller design for the cogeneration plant and calculated the operating amounts of system control and also provided related subjects for further exploration. * The author **The advisor Ming-Shing Young 楊明興 2002 學位論文 ; thesis 90 zh-TW |
collection |
NDLTD |
language |
zh-TW |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 國立成功大學 === 電機工程學系碩博士班 === 90 === Application of Fuzzy Control Theory and Taguchi
Methods to Boiler Automatic Combustion Control
of Cogeneration Plant
Guo-shyong Yang* Ming-Shing Young**
Department of Electrical Engineering
National Cheng Kung University , Tainan , Taiwan , R.O.C
Abstract
This thesis is mainly explore that the application of fuzzy control on the boiler Automatic Combustion Control (ACC) of the cogeneration plant. As the boiler combustion system is a non-linear system and the quality of system will be various with the changes of time. Hence, it is often essential for operator to adjust anew the control parameters of PID to adapt variation in the quality of system. Contrary, it is not necessary for a fuzzy control. Therefore, we can get a better control effect.
This research is to take aim on the Boiler Automatic Combustion of the cogeneration plant, which in nature is a complex system of non-linear and time-delay of combustion. We employed the fuzzy control theory for the design of the fuzzy controller and for the comparison of control efficacy between PID control and fuzzy control under the transfer function model of the boiler combustion system with different combustion time-delay. Moreover, for the design of the fuzzy controller, the membership function that designer choose may not always be the best combination of membership function parameters. Therefore, in this study, we introduced the Taguchi Quality Experiment Method, which through the way of Orthogonal Array experiment, we solved for a set of best parameters combination for input variable membership function enabling higher level of fuzzy control efficiencies.
In the final section of the thesis, coordinating actual Automatic Combustion Control operation with fuzzy control theory, we then proceeded with the fuzzy controller design for the cogeneration plant and calculated the operating amounts of system control and also provided related subjects for further exploration.
* The author
**The advisor
|
author2 |
Ming-Shing Young |
author_facet |
Ming-Shing Young Guo-Shyong Yang 楊國雄 |
author |
Guo-Shyong Yang 楊國雄 |
spellingShingle |
Guo-Shyong Yang 楊國雄 Application of Fuzzy Control Theory and Taguchi Methods to Boiler Automatic Combustion Control of Cogeneration Plant |
author_sort |
Guo-Shyong Yang |
title |
Application of Fuzzy Control Theory and Taguchi Methods to Boiler Automatic Combustion Control of Cogeneration Plant |
title_short |
Application of Fuzzy Control Theory and Taguchi Methods to Boiler Automatic Combustion Control of Cogeneration Plant |
title_full |
Application of Fuzzy Control Theory and Taguchi Methods to Boiler Automatic Combustion Control of Cogeneration Plant |
title_fullStr |
Application of Fuzzy Control Theory and Taguchi Methods to Boiler Automatic Combustion Control of Cogeneration Plant |
title_full_unstemmed |
Application of Fuzzy Control Theory and Taguchi Methods to Boiler Automatic Combustion Control of Cogeneration Plant |
title_sort |
application of fuzzy control theory and taguchi methods to boiler automatic combustion control of cogeneration plant |
publishDate |
2002 |
url |
http://ndltd.ncl.edu.tw/handle/20074582688081424457 |
work_keys_str_mv |
AT guoshyongyang applicationoffuzzycontroltheoryandtaguchimethodstoboilerautomaticcombustioncontrolofcogenerationplant AT yángguóxióng applicationoffuzzycontroltheoryandtaguchimethodstoboilerautomaticcombustioncontrolofcogenerationplant AT guoshyongyang yīngyòngmóhúkòngzhìlǐlùnyǔtiánkǒufāngfǎyúqìdiàngòngshēngchǎngguōlúzìdòngránshāokòngzhìzhīyánjiū AT yángguóxióng yīngyòngmóhúkòngzhìlǐlùnyǔtiánkǒufāngfǎyúqìdiàngòngshēngchǎngguōlúzìdòngránshāokòngzhìzhīyánjiū |
_version_ |
1718298907299020800 |