The Measurement, Analysis, and Test of Hysteresis curve for an Amorphous Core Transformer

碩士 === 中原大學 === 電機工程研究所 === 90 === This thesis analyzes the saturation characters of amorphous core transformer and re-establish it’s hysteresis loops by field measurement. The hysteresis loops of silicon steel core transformer are also measured. Then the results are compared. We measure the differ...

Full description

Bibliographic Details
Main Authors: Ching-Ming Chou, 周錦明
Other Authors: Jin-Maun Ho
Format: Others
Language:zh-TW
Published: 2002
Online Access:http://ndltd.ncl.edu.tw/handle/02485146527915366634
id ndltd-TW-090CYCU5442057
record_format oai_dc
spelling ndltd-TW-090CYCU54420572015-10-13T17:35:25Z http://ndltd.ncl.edu.tw/handle/02485146527915366634 The Measurement, Analysis, and Test of Hysteresis curve for an Amorphous Core Transformer 非晶質鐵心變壓器磁滯迴線的求取分析與測試 Ching-Ming Chou 周錦明 碩士 中原大學 電機工程研究所 90 This thesis analyzes the saturation characters of amorphous core transformer and re-establish it’s hysteresis loops by field measurement. The hysteresis loops of silicon steel core transformer are also measured. Then the results are compared. We measure the different core transformers(single-phase, 6900/240 V, 25KVA) each by means of harmonic voltage generator and power quality recorder. In this experiment, the test voltages(RMS value) are chosen from 160V to 265V. We find the iron loss and hysteresis loss of amorphous core transformer are about one-third of silicon steel core transformer. However the copper loss is not much difference. We hope that the results can serve as useful reference for the designer and user of transformer. Jin-Maun Ho 何金滿 2002 學位論文 ; thesis 89 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 中原大學 === 電機工程研究所 === 90 === This thesis analyzes the saturation characters of amorphous core transformer and re-establish it’s hysteresis loops by field measurement. The hysteresis loops of silicon steel core transformer are also measured. Then the results are compared. We measure the different core transformers(single-phase, 6900/240 V, 25KVA) each by means of harmonic voltage generator and power quality recorder. In this experiment, the test voltages(RMS value) are chosen from 160V to 265V. We find the iron loss and hysteresis loss of amorphous core transformer are about one-third of silicon steel core transformer. However the copper loss is not much difference. We hope that the results can serve as useful reference for the designer and user of transformer.
author2 Jin-Maun Ho
author_facet Jin-Maun Ho
Ching-Ming Chou
周錦明
author Ching-Ming Chou
周錦明
spellingShingle Ching-Ming Chou
周錦明
The Measurement, Analysis, and Test of Hysteresis curve for an Amorphous Core Transformer
author_sort Ching-Ming Chou
title The Measurement, Analysis, and Test of Hysteresis curve for an Amorphous Core Transformer
title_short The Measurement, Analysis, and Test of Hysteresis curve for an Amorphous Core Transformer
title_full The Measurement, Analysis, and Test of Hysteresis curve for an Amorphous Core Transformer
title_fullStr The Measurement, Analysis, and Test of Hysteresis curve for an Amorphous Core Transformer
title_full_unstemmed The Measurement, Analysis, and Test of Hysteresis curve for an Amorphous Core Transformer
title_sort measurement, analysis, and test of hysteresis curve for an amorphous core transformer
publishDate 2002
url http://ndltd.ncl.edu.tw/handle/02485146527915366634
work_keys_str_mv AT chingmingchou themeasurementanalysisandtestofhysteresiscurveforanamorphouscoretransformer
AT zhōujǐnmíng themeasurementanalysisandtestofhysteresiscurveforanamorphouscoretransformer
AT chingmingchou fēijīngzhìtiěxīnbiànyāqìcízhìhuíxiàndeqiúqǔfēnxīyǔcèshì
AT zhōujǐnmíng fēijīngzhìtiěxīnbiànyāqìcízhìhuíxiàndeqiúqǔfēnxīyǔcèshì
AT chingmingchou measurementanalysisandtestofhysteresiscurveforanamorphouscoretransformer
AT zhōujǐnmíng measurementanalysisandtestofhysteresiscurveforanamorphouscoretransformer
_version_ 1717782932407451648