The Analysis & Test of Harmonic Effects on Amorphous Metal Cored Transformers
碩士 === 中原大學 === 電機工程研究所 === 90 === In recent years, power electronic loads have been used widely, therefor, many harmonic current sources exist in the power system, this will affect loads and power system, components cause distribute power quality poor, additional losses, and misfunction of devices....
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | zh-TW |
Published: |
2002
|
Online Access: | http://ndltd.ncl.edu.tw/handle/13194671011427152757 |
id |
ndltd-TW-090CYCU5442042 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-090CYCU54420422015-10-13T17:35:25Z http://ndltd.ncl.edu.tw/handle/13194671011427152757 The Analysis & Test of Harmonic Effects on Amorphous Metal Cored Transformers 諧波對非晶質鐵心變壓器的性能影響分析與測試 Yung-Chin Chien 簡永欽 碩士 中原大學 電機工程研究所 90 In recent years, power electronic loads have been used widely, therefor, many harmonic current sources exist in the power system, this will affect loads and power system, components cause distribute power quality poor, additional losses, and misfunction of devices. In this thesis, the effects of harmonics on amorphous and silicon steel 25KVA transformers of distribution system are analyzed. Using Chroma ac source 6512 harmonic voltage generator and ADX3010 power quality analyzer to do unload (open circuit and short circuit) and loaded experiments on transformer under harmonic conditions. Hope that it can be a good reference for transformer designers and users. Jin-Maun Ho 何金滿 2002 學位論文 ; thesis 80 zh-TW |
collection |
NDLTD |
language |
zh-TW |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 中原大學 === 電機工程研究所 === 90 === In recent years, power electronic loads have been used widely, therefor, many harmonic current sources exist in the power system, this will affect loads and power system, components cause distribute power quality poor, additional losses, and misfunction of devices.
In this thesis, the effects of harmonics on amorphous and silicon steel 25KVA transformers of distribution system are analyzed. Using Chroma ac source 6512 harmonic voltage generator and ADX3010 power quality analyzer to do unload (open circuit and short circuit) and loaded experiments on transformer under harmonic conditions.
Hope that it can be a good reference for transformer designers and users.
|
author2 |
Jin-Maun Ho |
author_facet |
Jin-Maun Ho Yung-Chin Chien 簡永欽 |
author |
Yung-Chin Chien 簡永欽 |
spellingShingle |
Yung-Chin Chien 簡永欽 The Analysis & Test of Harmonic Effects on Amorphous Metal Cored Transformers |
author_sort |
Yung-Chin Chien |
title |
The Analysis & Test of Harmonic Effects on Amorphous Metal Cored Transformers |
title_short |
The Analysis & Test of Harmonic Effects on Amorphous Metal Cored Transformers |
title_full |
The Analysis & Test of Harmonic Effects on Amorphous Metal Cored Transformers |
title_fullStr |
The Analysis & Test of Harmonic Effects on Amorphous Metal Cored Transformers |
title_full_unstemmed |
The Analysis & Test of Harmonic Effects on Amorphous Metal Cored Transformers |
title_sort |
analysis & test of harmonic effects on amorphous metal cored transformers |
publishDate |
2002 |
url |
http://ndltd.ncl.edu.tw/handle/13194671011427152757 |
work_keys_str_mv |
AT yungchinchien theanalysistestofharmoniceffectsonamorphousmetalcoredtransformers AT jiǎnyǒngqīn theanalysistestofharmoniceffectsonamorphousmetalcoredtransformers AT yungchinchien xiébōduìfēijīngzhìtiěxīnbiànyāqìdexìngnéngyǐngxiǎngfēnxīyǔcèshì AT jiǎnyǒngqīn xiébōduìfēijīngzhìtiěxīnbiànyāqìdexìngnéngyǐngxiǎngfēnxīyǔcèshì AT yungchinchien analysistestofharmoniceffectsonamorphousmetalcoredtransformers AT jiǎnyǒngqīn analysistestofharmoniceffectsonamorphousmetalcoredtransformers |
_version_ |
1717782924854558720 |