The Analysis & Test of Harmonic Effects on Amorphous Metal Cored Transformers

碩士 === 中原大學 === 電機工程研究所 === 90 === In recent years, power electronic loads have been used widely, therefor, many harmonic current sources exist in the power system, this will affect loads and power system, components cause distribute power quality poor, additional losses, and misfunction of devices....

Full description

Bibliographic Details
Main Authors: Yung-Chin Chien, 簡永欽
Other Authors: Jin-Maun Ho
Format: Others
Language:zh-TW
Published: 2002
Online Access:http://ndltd.ncl.edu.tw/handle/13194671011427152757
id ndltd-TW-090CYCU5442042
record_format oai_dc
spelling ndltd-TW-090CYCU54420422015-10-13T17:35:25Z http://ndltd.ncl.edu.tw/handle/13194671011427152757 The Analysis & Test of Harmonic Effects on Amorphous Metal Cored Transformers 諧波對非晶質鐵心變壓器的性能影響分析與測試 Yung-Chin Chien 簡永欽 碩士 中原大學 電機工程研究所 90 In recent years, power electronic loads have been used widely, therefor, many harmonic current sources exist in the power system, this will affect loads and power system, components cause distribute power quality poor, additional losses, and misfunction of devices. In this thesis, the effects of harmonics on amorphous and silicon steel 25KVA transformers of distribution system are analyzed. Using Chroma ac source 6512 harmonic voltage generator and ADX3010 power quality analyzer to do unload (open circuit and short circuit) and loaded experiments on transformer under harmonic conditions. Hope that it can be a good reference for transformer designers and users. Jin-Maun Ho 何金滿 2002 學位論文 ; thesis 80 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 中原大學 === 電機工程研究所 === 90 === In recent years, power electronic loads have been used widely, therefor, many harmonic current sources exist in the power system, this will affect loads and power system, components cause distribute power quality poor, additional losses, and misfunction of devices. In this thesis, the effects of harmonics on amorphous and silicon steel 25KVA transformers of distribution system are analyzed. Using Chroma ac source 6512 harmonic voltage generator and ADX3010 power quality analyzer to do unload (open circuit and short circuit) and loaded experiments on transformer under harmonic conditions. Hope that it can be a good reference for transformer designers and users.
author2 Jin-Maun Ho
author_facet Jin-Maun Ho
Yung-Chin Chien
簡永欽
author Yung-Chin Chien
簡永欽
spellingShingle Yung-Chin Chien
簡永欽
The Analysis & Test of Harmonic Effects on Amorphous Metal Cored Transformers
author_sort Yung-Chin Chien
title The Analysis & Test of Harmonic Effects on Amorphous Metal Cored Transformers
title_short The Analysis & Test of Harmonic Effects on Amorphous Metal Cored Transformers
title_full The Analysis & Test of Harmonic Effects on Amorphous Metal Cored Transformers
title_fullStr The Analysis & Test of Harmonic Effects on Amorphous Metal Cored Transformers
title_full_unstemmed The Analysis & Test of Harmonic Effects on Amorphous Metal Cored Transformers
title_sort analysis & test of harmonic effects on amorphous metal cored transformers
publishDate 2002
url http://ndltd.ncl.edu.tw/handle/13194671011427152757
work_keys_str_mv AT yungchinchien theanalysistestofharmoniceffectsonamorphousmetalcoredtransformers
AT jiǎnyǒngqīn theanalysistestofharmoniceffectsonamorphousmetalcoredtransformers
AT yungchinchien xiébōduìfēijīngzhìtiěxīnbiànyāqìdexìngnéngyǐngxiǎngfēnxīyǔcèshì
AT jiǎnyǒngqīn xiébōduìfēijīngzhìtiěxīnbiànyāqìdexìngnéngyǐngxiǎngfēnxīyǔcèshì
AT yungchinchien analysistestofharmoniceffectsonamorphousmetalcoredtransformers
AT jiǎnyǒngqīn analysistestofharmoniceffectsonamorphousmetalcoredtransformers
_version_ 1717782924854558720