Ground potential Distribution and Its affections When A Ground Fault occurred on the Traction Power Substation of Metropolitan Rapid Transit System

碩士 === 中原大學 === 電機工程研究所 === 90 === ABSTRACT The metropolitan rapid transit system(MRTS)passes through urban area with thick people distribution. The first consideration to MRTS is safety, i.e., the MRTS must be safe for people and equipments. Many factors affect the safety of MRTS, in which the hig...

Full description

Bibliographic Details
Main Authors: Li-Long Tu, 涂立榮
Other Authors: Chih-Ju Chou
Format: Others
Language:zh-TW
Published: 2002
Online Access:http://ndltd.ncl.edu.tw/handle/84592554169324398041
id ndltd-TW-090CYCU5442002
record_format oai_dc
spelling ndltd-TW-090CYCU54420022015-10-13T17:35:24Z http://ndltd.ncl.edu.tw/handle/84592554169324398041 Ground potential Distribution and Its affections When A Ground Fault occurred on the Traction Power Substation of Metropolitan Rapid Transit System 大眾捷運系統牽引動力變電站接地故障之地電位分佈及其影響研究 Li-Long Tu 涂立榮 碩士 中原大學 電機工程研究所 90 ABSTRACT The metropolitan rapid transit system(MRTS)passes through urban area with thick people distribution. The first consideration to MRTS is safety, i.e., the MRTS must be safe for people and equipments. Many factors affect the safety of MRTS, in which the high voltage ground fault occurred on the traction power substation is very critical to people and system. This is because of that the ground fault will not only cause the traction power system to tript out of service but also cause the grounding system to produce ground potential rise(GPR)which will be transferred to other places by some interconnected conductors to form transferred voltages to damage personnel and equipments, especially, the damage of transferred voltage may occurred on rail way, passenger stations, control center, maintenance/repair depot, etc. At present, the domestic MRTS are still in the initial stage with lack of experience in ground faults. In the problem of ground fault, although the grounding resistance had been considered in the design of each substation grounding system, the damage of transferred voltage can not be full characterized by grounding resistance without analysis of grounding potential distribution of the whole MRTS. The proposal is aimed to study the ground potential distribution when a ground fault occurred on the traction power substation of an operated MRTS. In this paper, the ground potential distribution due to the ground fault on the traction power substation of metropolitan rapid transit systems (MRTS) and its affections are studied. The circuit model is called "the cross-bonding ladder circuit model". The circuit model represents the interconnected ground system of MRTS is first constructed, in which all the grounding systems of traction power substation and various interconnects conductors are considered. The ground potential rise (GPR) and the associated transfer voltages at the critical positions are analyzed by using the circuit model. Finally, the affections of GPR and the transfer voltages on the personnel and equipments are assessed. Chih-Ju Chou 周至如 2002 學位論文 ; thesis 241 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 中原大學 === 電機工程研究所 === 90 === ABSTRACT The metropolitan rapid transit system(MRTS)passes through urban area with thick people distribution. The first consideration to MRTS is safety, i.e., the MRTS must be safe for people and equipments. Many factors affect the safety of MRTS, in which the high voltage ground fault occurred on the traction power substation is very critical to people and system. This is because of that the ground fault will not only cause the traction power system to tript out of service but also cause the grounding system to produce ground potential rise(GPR)which will be transferred to other places by some interconnected conductors to form transferred voltages to damage personnel and equipments, especially, the damage of transferred voltage may occurred on rail way, passenger stations, control center, maintenance/repair depot, etc. At present, the domestic MRTS are still in the initial stage with lack of experience in ground faults. In the problem of ground fault, although the grounding resistance had been considered in the design of each substation grounding system, the damage of transferred voltage can not be full characterized by grounding resistance without analysis of grounding potential distribution of the whole MRTS. The proposal is aimed to study the ground potential distribution when a ground fault occurred on the traction power substation of an operated MRTS. In this paper, the ground potential distribution due to the ground fault on the traction power substation of metropolitan rapid transit systems (MRTS) and its affections are studied. The circuit model is called "the cross-bonding ladder circuit model". The circuit model represents the interconnected ground system of MRTS is first constructed, in which all the grounding systems of traction power substation and various interconnects conductors are considered. The ground potential rise (GPR) and the associated transfer voltages at the critical positions are analyzed by using the circuit model. Finally, the affections of GPR and the transfer voltages on the personnel and equipments are assessed.
author2 Chih-Ju Chou
author_facet Chih-Ju Chou
Li-Long Tu
涂立榮
author Li-Long Tu
涂立榮
spellingShingle Li-Long Tu
涂立榮
Ground potential Distribution and Its affections When A Ground Fault occurred on the Traction Power Substation of Metropolitan Rapid Transit System
author_sort Li-Long Tu
title Ground potential Distribution and Its affections When A Ground Fault occurred on the Traction Power Substation of Metropolitan Rapid Transit System
title_short Ground potential Distribution and Its affections When A Ground Fault occurred on the Traction Power Substation of Metropolitan Rapid Transit System
title_full Ground potential Distribution and Its affections When A Ground Fault occurred on the Traction Power Substation of Metropolitan Rapid Transit System
title_fullStr Ground potential Distribution and Its affections When A Ground Fault occurred on the Traction Power Substation of Metropolitan Rapid Transit System
title_full_unstemmed Ground potential Distribution and Its affections When A Ground Fault occurred on the Traction Power Substation of Metropolitan Rapid Transit System
title_sort ground potential distribution and its affections when a ground fault occurred on the traction power substation of metropolitan rapid transit system
publishDate 2002
url http://ndltd.ncl.edu.tw/handle/84592554169324398041
work_keys_str_mv AT lilongtu groundpotentialdistributionanditsaffectionswhenagroundfaultoccurredonthetractionpowersubstationofmetropolitanrapidtransitsystem
AT túlìróng groundpotentialdistributionanditsaffectionswhenagroundfaultoccurredonthetractionpowersubstationofmetropolitanrapidtransitsystem
AT lilongtu dàzhòngjiéyùnxìtǒngqiānyǐndònglìbiàndiànzhànjiēdegùzhàngzhīdediànwèifēnbùjíqíyǐngxiǎngyánjiū
AT túlìróng dàzhòngjiéyùnxìtǒngqiānyǐndònglìbiàndiànzhànjiēdegùzhàngzhīdediànwèifēnbùjíqíyǐngxiǎngyánjiū
_version_ 1717782904258428928