Application of Fuzzy Logic Controller for Variable Frequency Control of Water Pumps in Parallel

碩士 === 國立臺北科技大學 === 機電整合研究所 === 89 === This research is focus on the pressure control in pipeline system by variable speed control of water pumps in parallel with fuzzy logic controller. The content of this research is about active control of variable speed pumps to suppress the surge pressure in th...

Full description

Bibliographic Details
Main Author: 劉景男
Other Authors: 陳雙源
Format: Others
Language:zh-TW
Published: 2001
Online Access:http://ndltd.ncl.edu.tw/handle/09363003558302140231
id ndltd-TW-089TIT00651013
record_format oai_dc
spelling ndltd-TW-089TIT006510132015-10-13T12:10:00Z http://ndltd.ncl.edu.tw/handle/09363003558302140231 Application of Fuzzy Logic Controller for Variable Frequency Control of Water Pumps in Parallel 應用模弧邏輯控制器於並聯水泵的變頻控制 劉景男 碩士 國立臺北科技大學 機電整合研究所 89 This research is focus on the pressure control in pipeline system by variable speed control of water pumps in parallel with fuzzy logic controller. The content of this research is about active control of variable speed pumps to suppress the surge pressure in the pipeline system. And also discussed in effects of suppressing the transient pressure and the pressure control of pipeline system, on three different models likes load of single pumps, load of multiple pumps by sequence control, load of multiple pumps by variable frequency synchronous and with tuning the variables of equipment. The research is consist of the followings. First, built a procedure of controller design for the pressure control system of water pumps in real time. Second, establish two constructs of controller of multiple pumps and two controllers of multiple pumps not only satisfying the pressure but also effectively suppressing the peak pressure wave when surge happens. All the results of experiment above two items are implemented through the procedure of theoretical analysis and experimental verification. In the research, the effects of controller of multiple pumps and two controllers of multiple pumps in the pressure control of pipeline system are fine. By comparing the result of using two controllers of multiple pumps to suppress the pressure peak decreases 60﹪due to response of open loop control, which also forces the pressure in pipeline obviously approaching the set value in a short period after water-hammer happened, so the result of suppressing the pressure peak value is fine. 陳雙源 2001 學位論文 ; thesis 111 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立臺北科技大學 === 機電整合研究所 === 89 === This research is focus on the pressure control in pipeline system by variable speed control of water pumps in parallel with fuzzy logic controller. The content of this research is about active control of variable speed pumps to suppress the surge pressure in the pipeline system. And also discussed in effects of suppressing the transient pressure and the pressure control of pipeline system, on three different models likes load of single pumps, load of multiple pumps by sequence control, load of multiple pumps by variable frequency synchronous and with tuning the variables of equipment. The research is consist of the followings. First, built a procedure of controller design for the pressure control system of water pumps in real time. Second, establish two constructs of controller of multiple pumps and two controllers of multiple pumps not only satisfying the pressure but also effectively suppressing the peak pressure wave when surge happens. All the results of experiment above two items are implemented through the procedure of theoretical analysis and experimental verification. In the research, the effects of controller of multiple pumps and two controllers of multiple pumps in the pressure control of pipeline system are fine. By comparing the result of using two controllers of multiple pumps to suppress the pressure peak decreases 60﹪due to response of open loop control, which also forces the pressure in pipeline obviously approaching the set value in a short period after water-hammer happened, so the result of suppressing the pressure peak value is fine.
author2 陳雙源
author_facet 陳雙源
劉景男
author 劉景男
spellingShingle 劉景男
Application of Fuzzy Logic Controller for Variable Frequency Control of Water Pumps in Parallel
author_sort 劉景男
title Application of Fuzzy Logic Controller for Variable Frequency Control of Water Pumps in Parallel
title_short Application of Fuzzy Logic Controller for Variable Frequency Control of Water Pumps in Parallel
title_full Application of Fuzzy Logic Controller for Variable Frequency Control of Water Pumps in Parallel
title_fullStr Application of Fuzzy Logic Controller for Variable Frequency Control of Water Pumps in Parallel
title_full_unstemmed Application of Fuzzy Logic Controller for Variable Frequency Control of Water Pumps in Parallel
title_sort application of fuzzy logic controller for variable frequency control of water pumps in parallel
publishDate 2001
url http://ndltd.ncl.edu.tw/handle/09363003558302140231
work_keys_str_mv AT liújǐngnán applicationoffuzzylogiccontrollerforvariablefrequencycontrolofwaterpumpsinparallel
AT liújǐngnán yīngyòngmóhúluójíkòngzhìqìyúbìngliánshuǐbèngdebiànpínkòngzhì
_version_ 1716854551057793024