Experimental study of heat transfer of corrugated channels

碩士 === 國立臺灣大學 === 機械工程學研究所 === 89 === This experimental study investigated the heat transfer characteristics of the corrugated channel appeared in plate heat exchangers (PHEs). A flow channel with wavy surfaces was constructed within which air was passed through. The temperature of the wall was main...

Full description

Bibliographic Details
Main Authors: Sun, Y.M., 孫禹銘
Other Authors: Su, C.C.
Format: Others
Language:zh-TW
Published: 2001
Online Access:http://ndltd.ncl.edu.tw/handle/37754120703168538823
id ndltd-TW-089NTU00489047
record_format oai_dc
spelling ndltd-TW-089NTU004890472016-07-04T04:17:15Z http://ndltd.ncl.edu.tw/handle/37754120703168538823 Experimental study of heat transfer of corrugated channels 彎曲流道板式熱交換器之研究 Sun, Y.M. 孫禹銘 碩士 國立臺灣大學 機械工程學研究所 89 This experimental study investigated the heat transfer characteristics of the corrugated channel appeared in plate heat exchangers (PHEs). A flow channel with wavy surfaces was constructed within which air was passed through. The temperature of the wall was maintained constant. Starting from the entrance, the air temperatures within two wavelengths were measured at about 300 locations. The Reynolds number of air was varied from 300 to 9000. Results show that both the average and local Nusselt numbers increase with the Reynolds number. However, the local Nusselt number decreases with the distance from the entrance and is greater at sections near the crest. In addition, both the average and local Nusselt numbers are apparently greater in the entrance region. Su, C.C. 蘇金佳 2001 學位論文 ; thesis 93 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立臺灣大學 === 機械工程學研究所 === 89 === This experimental study investigated the heat transfer characteristics of the corrugated channel appeared in plate heat exchangers (PHEs). A flow channel with wavy surfaces was constructed within which air was passed through. The temperature of the wall was maintained constant. Starting from the entrance, the air temperatures within two wavelengths were measured at about 300 locations. The Reynolds number of air was varied from 300 to 9000. Results show that both the average and local Nusselt numbers increase with the Reynolds number. However, the local Nusselt number decreases with the distance from the entrance and is greater at sections near the crest. In addition, both the average and local Nusselt numbers are apparently greater in the entrance region.
author2 Su, C.C.
author_facet Su, C.C.
Sun, Y.M.
孫禹銘
author Sun, Y.M.
孫禹銘
spellingShingle Sun, Y.M.
孫禹銘
Experimental study of heat transfer of corrugated channels
author_sort Sun, Y.M.
title Experimental study of heat transfer of corrugated channels
title_short Experimental study of heat transfer of corrugated channels
title_full Experimental study of heat transfer of corrugated channels
title_fullStr Experimental study of heat transfer of corrugated channels
title_full_unstemmed Experimental study of heat transfer of corrugated channels
title_sort experimental study of heat transfer of corrugated channels
publishDate 2001
url http://ndltd.ncl.edu.tw/handle/37754120703168538823
work_keys_str_mv AT sunym experimentalstudyofheattransferofcorrugatedchannels
AT sūnyǔmíng experimentalstudyofheattransferofcorrugatedchannels
AT sunym wānqūliúdàobǎnshìrèjiāohuànqìzhīyánjiū
AT sūnyǔmíng wānqūliúdàobǎnshìrèjiāohuànqìzhīyánjiū
_version_ 1718334618790264832