Two-step Process Control for Autocorrelated data
碩士 === 國立政治大學 === 統計學系 === 89 === Most products are produced by several process steps and have more than one interested quality characteristics. If each step of the process is independent, and the observations taken from the process are also independent then we may use Shewhart control ch...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | zh-TW |
Published: |
2001
|
Online Access: | http://ndltd.ncl.edu.tw/handle/92885119849997227404 |
id |
ndltd-TW-089NCCU0337016 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-089NCCU03370162016-07-06T04:10:44Z http://ndltd.ncl.edu.tw/handle/92885119849997227404 Two-step Process Control for Autocorrelated data 數據相關之二階製程管制 Chen Wei Lun 陳維倫 碩士 國立政治大學 統計學系 89 Most products are produced by several process steps and have more than one interested quality characteristics. If each step of the process is independent, and the observations taken from the process are also independent then we may use Shewhart control chart at each step. However, in many processes, most production steps are dependent and the observations taken from the process are correlated. In this research, we consider the process has two dependent steps and the observations taken from the process are correlated over time. We construct the individual residual control chart to monitor the previous process and the cause-selecting control chart to monitor the current process. Then simulate all the states occur in the process and present the individual residual control chart and the cause-selecting control chart of the simulations. Furthermore compare the proposed control charts with the Hotelling T2 control chart. At last, we give an example to illustrate how to construct the proposed control charts. From the proposed control charts, we can determine which step of the process is out of control easily. If there is a signal in the individual residual control chart, it means the previous process is out of control. If there is a signal in the cause-selecting control chart, it means the current process is out of control. The Hotelling T2 control chart only indicate the process is out of control but does not detect which step of the process is out of control. 楊素芬 2001 學位論文 ; thesis 103 zh-TW |
collection |
NDLTD |
language |
zh-TW |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 國立政治大學 === 統計學系 === 89 === Most products are produced by several process steps and have more than one interested quality characteristics. If each step of the process is independent, and the observations taken from the process are also independent then we may use Shewhart control chart at each step. However, in many processes, most production steps are dependent and the observations taken from the process are correlated. In this research, we consider the process has two dependent steps and the observations taken from the process are correlated over time. We construct the individual residual control chart to monitor the previous process and the cause-selecting control chart to monitor the current process. Then simulate all the states occur in the process and present the individual residual control chart and the cause-selecting control chart of the simulations. Furthermore compare the proposed control charts with the Hotelling T2 control chart. At last, we give an example to illustrate how to construct the proposed control charts.
From the proposed control charts, we can determine which step of the process is out of control easily. If there is a signal in the individual residual control chart, it means the previous process is out of control. If there is a signal in the cause-selecting control chart, it means the current process is out of control. The Hotelling T2 control chart only indicate the process is out of control but does not detect which step of the process is out of control.
|
author2 |
楊素芬 |
author_facet |
楊素芬 Chen Wei Lun 陳維倫 |
author |
Chen Wei Lun 陳維倫 |
spellingShingle |
Chen Wei Lun 陳維倫 Two-step Process Control for Autocorrelated data |
author_sort |
Chen Wei Lun |
title |
Two-step Process Control for Autocorrelated data |
title_short |
Two-step Process Control for Autocorrelated data |
title_full |
Two-step Process Control for Autocorrelated data |
title_fullStr |
Two-step Process Control for Autocorrelated data |
title_full_unstemmed |
Two-step Process Control for Autocorrelated data |
title_sort |
two-step process control for autocorrelated data |
publishDate |
2001 |
url |
http://ndltd.ncl.edu.tw/handle/92885119849997227404 |
work_keys_str_mv |
AT chenweilun twostepprocesscontrolforautocorrelateddata AT chénwéilún twostepprocesscontrolforautocorrelateddata AT chenweilun shùjùxiāngguānzhīèrjiēzhìchéngguǎnzhì AT chénwéilún shùjùxiāngguānzhīèrjiēzhìchéngguǎnzhì |
_version_ |
1718338521153929216 |