Measurement of Performance and Analysis for a P.C. Cooling Fan
碩士 === 中華大學 === 機械與航太工程研究所 === 89 === The purpose of this study is using a duct flow to measure the performance of personal computers cooling fans . By using different rectilinear guided vanes of angle 0∘、30∘、45∘、60∘、72∘, to study the recovery of swirling pressure . The position of these...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | zh-TW |
Published: |
2001
|
Online Access: | http://ndltd.ncl.edu.tw/handle/59602627821663902616 |
id |
ndltd-TW-089CHPI0598025 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-089CHPI05980252015-10-13T12:43:58Z http://ndltd.ncl.edu.tw/handle/59602627821663902616 Measurement of Performance and Analysis for a P.C. Cooling Fan 個人電腦冷卻風扇性能量測與分析 Lin,Chien-Chang 林建璋 碩士 中華大學 機械與航太工程研究所 89 The purpose of this study is using a duct flow to measure the performance of personal computers cooling fans . By using different rectilinear guided vanes of angle 0∘、30∘、45∘、60∘、72∘, to study the recovery of swirling pressure . The position of these guided vanes is placed downsstream of the fan by a distance of 5 , 15 , 25 cm . The test results show the performance of the fan does not significantly alter by the guide vane position . The maximum difference of 8 ﹪is obtained . This shows the wall friction effect is not strong to deteriorate the recovering of the pressure . The overall performance of the fans is compared with the results from factory and National Tsing-Hua University . There is widely difference among these three tests . Clearly , a standard procedure and treatment of small cooling fan is necessary to gain the overall feature of the design . The detail measurement of the fan outlet flow field is done by pitot-static tube and hot-wire . The different of these two instrument reading is about 20 ﹪, the flow angle measurement has a difference of 15 ﹪. From these two test methods all show a 24﹪of unrecovery pressure by the rectilinear vanes compared to the downstream pressure data . Four different designs of the fan is used to compare , their overall performance . Fan A is a free vortex design . Fan B is a high loading blade design . Fan C&D are force vortex design but has a 6∘different turning on the blade . The deviation angle of fan C is the smallest one . But the overall performance fan D is the best one . For high loading fan B , the deviation angle is more than 60∘. Yang,Yi-Lung 楊一龍 2001 學位論文 ; thesis 89 zh-TW |
collection |
NDLTD |
language |
zh-TW |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 中華大學 === 機械與航太工程研究所 === 89 === The purpose of this study is using a duct flow to measure the performance of personal computers cooling fans . By using different rectilinear guided vanes of angle 0∘、30∘、45∘、60∘、72∘, to study the recovery of swirling pressure . The position of these guided vanes is placed downsstream of the fan by a distance of 5 , 15 , 25 cm . The test results show the
performance of the fan does not significantly alter by the guide vane position . The maximum difference of 8 ﹪is obtained . This shows the wall friction effect is not strong to deteriorate the recovering of the pressure . The overall performance of the fans is compared with the results from
factory and National Tsing-Hua University . There is widely difference among these three tests . Clearly , a standard procedure and treatment of small cooling fan is necessary to gain the overall feature of the design . The detail measurement of the fan outlet flow field is done by pitot-static tube and hot-wire . The different of these two instrument reading is about 20 ﹪, the flow angle measurement has a difference of 15 ﹪. From these two test methods all show a 24﹪of unrecovery pressure by the rectilinear vanes compared to the downstream pressure data . Four different designs of the fan is used to compare , their overall performance . Fan A is a free vortex design . Fan B is a high loading blade design . Fan C&D are force vortex design but has a 6∘different turning on the blade . The deviation angle of fan C is the smallest one . But the overall performance fan D is the best one . For high loading fan B , the deviation angle is more than 60∘.
|
author2 |
Yang,Yi-Lung |
author_facet |
Yang,Yi-Lung Lin,Chien-Chang 林建璋 |
author |
Lin,Chien-Chang 林建璋 |
spellingShingle |
Lin,Chien-Chang 林建璋 Measurement of Performance and Analysis for a P.C. Cooling Fan |
author_sort |
Lin,Chien-Chang |
title |
Measurement of Performance and Analysis for a P.C. Cooling Fan |
title_short |
Measurement of Performance and Analysis for a P.C. Cooling Fan |
title_full |
Measurement of Performance and Analysis for a P.C. Cooling Fan |
title_fullStr |
Measurement of Performance and Analysis for a P.C. Cooling Fan |
title_full_unstemmed |
Measurement of Performance and Analysis for a P.C. Cooling Fan |
title_sort |
measurement of performance and analysis for a p.c. cooling fan |
publishDate |
2001 |
url |
http://ndltd.ncl.edu.tw/handle/59602627821663902616 |
work_keys_str_mv |
AT linchienchang measurementofperformanceandanalysisforapccoolingfan AT línjiànzhāng measurementofperformanceandanalysisforapccoolingfan AT linchienchang gèréndiànnǎolěngquèfēngshànxìngnéngliàngcèyǔfēnxī AT línjiànzhāng gèréndiànnǎolěngquèfēngshànxìngnéngliàngcèyǔfēnxī |
_version_ |
1716864846102790144 |