Effect of the ratio bo/d on Punching Shear Strength of Reinforced Concrete Slabs Loaded through a L -Shape Column
碩士 === 國立臺灣科技大學 === 營建工程系 === 88 === Currently, the punching shear strength of reinforced concrete slabs is calculated using the provisions of Section 11.12 of ACI 318-95. However, the provisions of Section 11.12 of ACI Building Code are primarily based on test results of reinforced low-...