Photoelastic Stress Analysis of O-ring and Magnet Attachment for Implant-Soft Tissue Retained Overdenture
碩士 === 國立臺灣科技大學 === 機械工程系 === 88 === This thesis deals with the stress analysis on the prosthetics . Especially,implant-soft tissue retainted overdenture. Photoelasticity will be used to analyze two kinds of stud type attachment ,one is O-ring attachment and the other is magnetic attachment. Various...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | zh-TW |
Published: |
2000
|
Online Access: | http://ndltd.ncl.edu.tw/handle/57885404260359375184 |
id |
ndltd-TW-088NTUST489041 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-088NTUST4890412016-01-29T04:18:55Z http://ndltd.ncl.edu.tw/handle/57885404260359375184 Photoelastic Stress Analysis of O-ring and Magnet Attachment for Implant-Soft Tissue Retained Overdenture 套環式和磁性式連接體之覆蓋義齒光彈應力分析 Chen-Chien Hung 陳建宏 碩士 國立臺灣科技大學 機械工程系 88 This thesis deals with the stress analysis on the prosthetics . Especially,implant-soft tissue retainted overdenture. Photoelasticity will be used to analyze two kinds of stud type attachment ,one is O-ring attachment and the other is magnetic attachment. Various loading conditions are applied to the overdenture,and the stress distribution near the implant is studied. Photoelastic birefringent material will be used to model the mandible. True size implant,attachment,and overdenture are setup to the model ,and exposed in a circularly polariscope system. Vertical and oblique occlusal force from 98.1 to 294.3N will be applied to the four location(43,46,33,36). Finally the result of photoelasticity pattern is analyzed to compared with each other between O-ring attachment and Magnetic attachment. The experiment shows that photoelasticity model reveals the stress in mandible successfully.When load is applied upon the implant(43,33),magnetic attachment type has much more stress than that of O-ring attachment type. When load is applied far away from the implant(46,36),O-ring attachment type has much more stress than that of Magnetic attachment type. Tseng-Chui Kung 曾垂拱 2000 學位論文 ; thesis 73 zh-TW |
collection |
NDLTD |
language |
zh-TW |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 國立臺灣科技大學 === 機械工程系 === 88 === This thesis deals with the stress analysis on the prosthetics . Especially,implant-soft tissue retainted overdenture. Photoelasticity will be used to analyze two kinds of stud type attachment ,one is O-ring attachment and the other is magnetic attachment. Various loading conditions are applied to the overdenture,and the stress distribution near the implant is studied. Photoelastic birefringent material will be used to model the mandible. True size implant,attachment,and overdenture are setup to the model ,and exposed in a circularly polariscope system. Vertical and oblique occlusal force from 98.1 to 294.3N will be applied to the four location(43,46,33,36). Finally the result of photoelasticity pattern is analyzed to compared with each other between O-ring attachment and Magnetic attachment. The experiment shows that photoelasticity model reveals the stress in mandible successfully.When load is applied upon the implant(43,33),magnetic attachment type has much more stress than that of O-ring attachment type. When load is applied far away from the implant(46,36),O-ring attachment type has much more stress than that of Magnetic attachment type.
|
author2 |
Tseng-Chui Kung |
author_facet |
Tseng-Chui Kung Chen-Chien Hung 陳建宏 |
author |
Chen-Chien Hung 陳建宏 |
spellingShingle |
Chen-Chien Hung 陳建宏 Photoelastic Stress Analysis of O-ring and Magnet Attachment for Implant-Soft Tissue Retained Overdenture |
author_sort |
Chen-Chien Hung |
title |
Photoelastic Stress Analysis of O-ring and Magnet Attachment for Implant-Soft Tissue Retained Overdenture |
title_short |
Photoelastic Stress Analysis of O-ring and Magnet Attachment for Implant-Soft Tissue Retained Overdenture |
title_full |
Photoelastic Stress Analysis of O-ring and Magnet Attachment for Implant-Soft Tissue Retained Overdenture |
title_fullStr |
Photoelastic Stress Analysis of O-ring and Magnet Attachment for Implant-Soft Tissue Retained Overdenture |
title_full_unstemmed |
Photoelastic Stress Analysis of O-ring and Magnet Attachment for Implant-Soft Tissue Retained Overdenture |
title_sort |
photoelastic stress analysis of o-ring and magnet attachment for implant-soft tissue retained overdenture |
publishDate |
2000 |
url |
http://ndltd.ncl.edu.tw/handle/57885404260359375184 |
work_keys_str_mv |
AT chenchienhung photoelasticstressanalysisoforingandmagnetattachmentforimplantsofttissueretainedoverdenture AT chénjiànhóng photoelasticstressanalysisoforingandmagnetattachmentforimplantsofttissueretainedoverdenture AT chenchienhung tàohuánshìhécíxìngshìliánjiētǐzhīfùgàiyìchǐguāngdànyīnglìfēnxī AT chénjiànhóng tàohuánshìhécíxìngshìliánjiētǐzhīfùgàiyìchǐguāngdànyīnglìfēnxī |
_version_ |
1718168171935956992 |