The Effect of Dispersed Generation Facilities on Distribution System Configurations

碩士 === 國立臺灣科技大學 === 電機工程系 === 88 ===   In order to raise the security and reliability of system operation, the dispersed small generation units have been adopted gradually instedad of using the large-scale generation usnits. In addition, the private-owned cogeneration systems have been encouraged to...

Full description

Bibliographic Details
Main Author: 鄭自強
Other Authors: 吳瑞南
Format: Others
Language:zh-TW
Published: 2000
Online Access:http://ndltd.ncl.edu.tw/handle/33221502298810726956
id ndltd-TW-088NTUS3442001
record_format oai_dc
spelling ndltd-TW-088NTUS34420012016-01-29T04:18:54Z http://ndltd.ncl.edu.tw/handle/33221502298810726956 The Effect of Dispersed Generation Facilities on Distribution System Configurations 分散式發電系統對不同結構配電系統之以響 鄭自強 碩士 國立臺灣科技大學 電機工程系 88   In order to raise the security and reliability of system operation, the dispersed small generation units have been adopted gradually instedad of using the large-scale generation usnits. In addition, the private-owned cogeneration systems have been encouraged to alleviate the shortage of electricity in Taiwan for many years since the electrican industry deregulation is looking after worldwide. It therefore becomes important to investigate the influences of the co-generation systems to the existing distribution systems from the view-points of configuration and operation. The influences are investigated based on two factors, voltage profile and short-circuit capacity.   In this thesis, the congeneration system is selected as the distributed generation facility in the example system because it is widely used in the existing power system. Besides, the mathematical formulation of components used in the distribution system such as transformer, line, load, are well, derived. These models are utilized in the example system to caryy out the simulation. In the simulation, two software packages, PSPICE and ETAP, are adopted to solve the system under the conditions of unbalance and balance respectively.   By varying the load, the output of the co-generation unit and the configuration of the systems, the voltage profile of buses and the short circuit capacity are examined. A nine-bus simple system and Taipower system are adopted as the example systems in this study. The results show that the presence of co-generation unit indeed makes influences. Besidens, the thesis attempts to transfer the distribution system configuration from the traditional radial type into ring type by the inclusion of the inter-connection switches between buses. It demonstrates that the voltage profile and short circuit capacity are indeed influenced influenced by the operation of inter-connection switches As a consequence, the electric performance of the existing devices of the radial type distribution system should be carefully considered before the system configuration is transformed into ring type. AII these maters are justified to conduct fufther study in the issue. 吳瑞南 2000 學位論文 ; thesis 107 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立臺灣科技大學 === 電機工程系 === 88 ===   In order to raise the security and reliability of system operation, the dispersed small generation units have been adopted gradually instedad of using the large-scale generation usnits. In addition, the private-owned cogeneration systems have been encouraged to alleviate the shortage of electricity in Taiwan for many years since the electrican industry deregulation is looking after worldwide. It therefore becomes important to investigate the influences of the co-generation systems to the existing distribution systems from the view-points of configuration and operation. The influences are investigated based on two factors, voltage profile and short-circuit capacity.   In this thesis, the congeneration system is selected as the distributed generation facility in the example system because it is widely used in the existing power system. Besides, the mathematical formulation of components used in the distribution system such as transformer, line, load, are well, derived. These models are utilized in the example system to caryy out the simulation. In the simulation, two software packages, PSPICE and ETAP, are adopted to solve the system under the conditions of unbalance and balance respectively.   By varying the load, the output of the co-generation unit and the configuration of the systems, the voltage profile of buses and the short circuit capacity are examined. A nine-bus simple system and Taipower system are adopted as the example systems in this study. The results show that the presence of co-generation unit indeed makes influences. Besidens, the thesis attempts to transfer the distribution system configuration from the traditional radial type into ring type by the inclusion of the inter-connection switches between buses. It demonstrates that the voltage profile and short circuit capacity are indeed influenced influenced by the operation of inter-connection switches As a consequence, the electric performance of the existing devices of the radial type distribution system should be carefully considered before the system configuration is transformed into ring type. AII these maters are justified to conduct fufther study in the issue.
author2 吳瑞南
author_facet 吳瑞南
鄭自強
author 鄭自強
spellingShingle 鄭自強
The Effect of Dispersed Generation Facilities on Distribution System Configurations
author_sort 鄭自強
title The Effect of Dispersed Generation Facilities on Distribution System Configurations
title_short The Effect of Dispersed Generation Facilities on Distribution System Configurations
title_full The Effect of Dispersed Generation Facilities on Distribution System Configurations
title_fullStr The Effect of Dispersed Generation Facilities on Distribution System Configurations
title_full_unstemmed The Effect of Dispersed Generation Facilities on Distribution System Configurations
title_sort effect of dispersed generation facilities on distribution system configurations
publishDate 2000
url http://ndltd.ncl.edu.tw/handle/33221502298810726956
work_keys_str_mv AT zhèngzìqiáng theeffectofdispersedgenerationfacilitiesondistributionsystemconfigurations
AT zhèngzìqiáng fēnsànshìfādiànxìtǒngduìbùtóngjiégòupèidiànxìtǒngzhīyǐxiǎng
AT zhèngzìqiáng effectofdispersedgenerationfacilitiesondistributionsystemconfigurations
_version_ 1718167950070906880