The Study of Application the Digital Image Technique for True Color Monitor in Wastewater

碩士 === 國立中央大學 === 環境工程研究所 === 88 === Generally, the measurement methods of true color, ADMI 3- or 31-wavelengths, are using artificially grab sampling to obtain a batch measured data. However, these approaches are difficult to know well the variations of water quality. The purpose of this study is...

Full description

Bibliographic Details
Main Authors: E-Hung Lei, 雷一弘
Other Authors: Shu-Liang Liaw
Format: Others
Language:zh-TW
Published: 2000
Online Access:http://ndltd.ncl.edu.tw/handle/99171026613752252255
id ndltd-TW-088NCU00515023
record_format oai_dc
spelling ndltd-TW-088NCU005150232016-07-08T04:22:53Z http://ndltd.ncl.edu.tw/handle/99171026613752252255 The Study of Application the Digital Image Technique for True Color Monitor in Wastewater 應用數位影像技術於廢水真色色度監測之研究 E-Hung Lei 雷一弘 碩士 國立中央大學 環境工程研究所 88 Generally, the measurement methods of true color, ADMI 3- or 31-wavelengths, are using artificially grab sampling to obtain a batch measured data. However, these approaches are difficult to know well the variations of water quality. The purpose of this study is to investigate the real-time and continuous monitoring method of true color by digital image produced from CCD digital camera. The study results reveal that the linear correlation coefficient (r) of digital image calibration curves are above 0.99. Using the standard solution of 250 ADMI to measure the feasibility of this method, the degree of accuracy and precision (RSD%) are 104.6±7.1% and 3.4% respectively, and the detection limit is 49ADMI. These results reveal the digital image method can measure the true color of wastewater accurately. Based upon the measurement of quality control to check the reproducibility, the relative errors of sample duplicate analysis is no more than 10%, and the recovery of quality sample analysis is within 100±6%. Combining the digital image method with the Visual Basic programming develops a continuous monitoring true color instrument to real-time automatic measure the true color of wastewater. The measured values and images can be saved in the database, and supply the inquire function. Using statistical t test to compare the measured results of digital image, 3- and 31-wavelength methods, the results reveal that no significant differences between the digital image and 31-wavelength approaches, the 3-wavelength approach measured values are higher than which measured by digital image and 31-wavelength methods. Shu-Liang Liaw 廖述良 2000 學位論文 ; thesis 122 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立中央大學 === 環境工程研究所 === 88 === Generally, the measurement methods of true color, ADMI 3- or 31-wavelengths, are using artificially grab sampling to obtain a batch measured data. However, these approaches are difficult to know well the variations of water quality. The purpose of this study is to investigate the real-time and continuous monitoring method of true color by digital image produced from CCD digital camera. The study results reveal that the linear correlation coefficient (r) of digital image calibration curves are above 0.99. Using the standard solution of 250 ADMI to measure the feasibility of this method, the degree of accuracy and precision (RSD%) are 104.6±7.1% and 3.4% respectively, and the detection limit is 49ADMI. These results reveal the digital image method can measure the true color of wastewater accurately. Based upon the measurement of quality control to check the reproducibility, the relative errors of sample duplicate analysis is no more than 10%, and the recovery of quality sample analysis is within 100±6%. Combining the digital image method with the Visual Basic programming develops a continuous monitoring true color instrument to real-time automatic measure the true color of wastewater. The measured values and images can be saved in the database, and supply the inquire function. Using statistical t test to compare the measured results of digital image, 3- and 31-wavelength methods, the results reveal that no significant differences between the digital image and 31-wavelength approaches, the 3-wavelength approach measured values are higher than which measured by digital image and 31-wavelength methods.
author2 Shu-Liang Liaw
author_facet Shu-Liang Liaw
E-Hung Lei
雷一弘
author E-Hung Lei
雷一弘
spellingShingle E-Hung Lei
雷一弘
The Study of Application the Digital Image Technique for True Color Monitor in Wastewater
author_sort E-Hung Lei
title The Study of Application the Digital Image Technique for True Color Monitor in Wastewater
title_short The Study of Application the Digital Image Technique for True Color Monitor in Wastewater
title_full The Study of Application the Digital Image Technique for True Color Monitor in Wastewater
title_fullStr The Study of Application the Digital Image Technique for True Color Monitor in Wastewater
title_full_unstemmed The Study of Application the Digital Image Technique for True Color Monitor in Wastewater
title_sort study of application the digital image technique for true color monitor in wastewater
publishDate 2000
url http://ndltd.ncl.edu.tw/handle/99171026613752252255
work_keys_str_mv AT ehunglei thestudyofapplicationthedigitalimagetechniquefortruecolormonitorinwastewater
AT léiyīhóng thestudyofapplicationthedigitalimagetechniquefortruecolormonitorinwastewater
AT ehunglei yīngyòngshùwèiyǐngxiàngjìshùyúfèishuǐzhēnsèsèdùjiāncèzhīyánjiū
AT léiyīhóng yīngyòngshùwèiyǐngxiàngjìshùyúfèishuǐzhēnsèsèdùjiāncèzhīyánjiū
AT ehunglei studyofapplicationthedigitalimagetechniquefortruecolormonitorinwastewater
AT léiyīhóng studyofapplicationthedigitalimagetechniquefortruecolormonitorinwastewater
_version_ 1718340151464165376