鋼筋混凝土梁結合補強及防蝕技術之開發

碩士 === 國立中央大學 === 土木工程研究所 === 88 === In this paper, behaviors of fiber reinforced plastic (FRP) retrofitted reinforced concrete beams with high chloride content and rebar corrosion under static loads were studied both experimentally and analytically. Test beams were characterized into three differen...

Full description

Bibliographic Details
Main Author: 胡智超
Other Authors: 王仲宇
Format: Others
Language:zh-TW
Published: 2000
Online Access:http://ndltd.ncl.edu.tw/handle/48916567927146450320
id ndltd-TW-088NCU00015016
record_format oai_dc
spelling ndltd-TW-088NCU000150162016-07-08T04:22:41Z http://ndltd.ncl.edu.tw/handle/48916567927146450320 鋼筋混凝土梁結合補強及防蝕技術之開發 胡智超 碩士 國立中央大學 土木工程研究所 88 In this paper, behaviors of fiber reinforced plastic (FRP) retrofitted reinforced concrete beams with high chloride content and rebar corrosion under static loads were studied both experimentally and analytically. Test beams were characterized into three different groups according to the states of corrosion damage: (I) control beam; (II) cathodic protection; and (III) accelerated corrosion. A new and effective anode sacrifice technique by patching thin plates on the surface of concrete structure was adopted to the retrofitting system. The load carrying capacities of all the beams with or without FRP patching were tested in the laboratory. Experimental results showed that the corrosion state of steel,water/cement ratio of concrete material,arrangements and the number of FRP patches affect the strength and failure mechanisms of the retrofitted RC beams. Simple analysis models and design concept for retrofitting the cracked and corroded RC beams strengthened by the FRP sheets are also presented and discussed. 王仲宇 2000 學位論文 ; thesis 0 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立中央大學 === 土木工程研究所 === 88 === In this paper, behaviors of fiber reinforced plastic (FRP) retrofitted reinforced concrete beams with high chloride content and rebar corrosion under static loads were studied both experimentally and analytically. Test beams were characterized into three different groups according to the states of corrosion damage: (I) control beam; (II) cathodic protection; and (III) accelerated corrosion. A new and effective anode sacrifice technique by patching thin plates on the surface of concrete structure was adopted to the retrofitting system. The load carrying capacities of all the beams with or without FRP patching were tested in the laboratory. Experimental results showed that the corrosion state of steel,water/cement ratio of concrete material,arrangements and the number of FRP patches affect the strength and failure mechanisms of the retrofitted RC beams. Simple analysis models and design concept for retrofitting the cracked and corroded RC beams strengthened by the FRP sheets are also presented and discussed.
author2 王仲宇
author_facet 王仲宇
胡智超
author 胡智超
spellingShingle 胡智超
鋼筋混凝土梁結合補強及防蝕技術之開發
author_sort 胡智超
title 鋼筋混凝土梁結合補強及防蝕技術之開發
title_short 鋼筋混凝土梁結合補強及防蝕技術之開發
title_full 鋼筋混凝土梁結合補強及防蝕技術之開發
title_fullStr 鋼筋混凝土梁結合補強及防蝕技術之開發
title_full_unstemmed 鋼筋混凝土梁結合補強及防蝕技術之開發
title_sort 鋼筋混凝土梁結合補強及防蝕技術之開發
publishDate 2000
url http://ndltd.ncl.edu.tw/handle/48916567927146450320
work_keys_str_mv AT húzhìchāo gāngjīnhùnníngtǔliángjiéhébǔqiángjífángshíjìshùzhīkāifā
_version_ 1718339729733189632