The Implementation and Performance Test of an Ultrasonic Phase-Shift Vibration Measurement System

碩士 === 義守大學 === 電子工程學系 === 88 === In this paper we introduce a High Precision Ultrasonic Vibration Measurement System . The measurement method of this system is based on an ultrasonic phase shift reconstruction principle . To achieve high precision , we use the Complex Programmable Logic Device ( C...

Full description

Bibliographic Details
Main Authors: Jung-Hong Lin, 林俊宏
Other Authors: Yan-Chay Li
Format: Others
Language:zh-TW
Published: 2000
Online Access:http://ndltd.ncl.edu.tw/handle/28641120672640591502
id ndltd-TW-088ISU00428006
record_format oai_dc
spelling ndltd-TW-088ISU004280062015-10-13T10:56:26Z http://ndltd.ncl.edu.tw/handle/28641120672640591502 The Implementation and Performance Test of an Ultrasonic Phase-Shift Vibration Measurement System 高精確度超音波相位差式震動量測系統之特性測試與系統實現 Jung-Hong Lin 林俊宏 碩士 義守大學 電子工程學系 88 In this paper we introduce a High Precision Ultrasonic Vibration Measurement System . The measurement method of this system is based on an ultrasonic phase shift reconstruction principle . To achieve high precision , we use the Complex Programmable Logic Device ( CPLD EPM7128SLC84 ) product of ALTERA CORPORATION to measure the ultrasonic phase-shift . The system use 80 Mhz oscillatory frequency to achieve high resolution . There are two single chip microcomputers is adopted in the system . One is used for communication with personal computer and implementing the ultrasonic phase-shift reconstruction from the ultrasonic phase-shift information . The other is used for measuring the ultrasonic performance . An experiment object is fixed on the steeping motor . To test the system performance , the single chip microcomputer control the movement of the object . To verify the performance of an ultrasonic vibration measurement system , a series of experiments has been designed . First experiment is to change the moving speed of the object . The second experiment is to change the sampling rate of the ultrasonic phase-shift information for reconstruction . After repeated experiments , We found the measurement error is ±0.000625% while the object moving speed is 0.8cm/sec and the sampling rate for ultrasonic phase-shift reconstruction is between 5 ~ 30 hz . Yan-Chay Li Sun-Lon Jen 李彥杰 任善隆 2000 學位論文 ; thesis 70 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 義守大學 === 電子工程學系 === 88 === In this paper we introduce a High Precision Ultrasonic Vibration Measurement System . The measurement method of this system is based on an ultrasonic phase shift reconstruction principle . To achieve high precision , we use the Complex Programmable Logic Device ( CPLD EPM7128SLC84 ) product of ALTERA CORPORATION to measure the ultrasonic phase-shift . The system use 80 Mhz oscillatory frequency to achieve high resolution . There are two single chip microcomputers is adopted in the system . One is used for communication with personal computer and implementing the ultrasonic phase-shift reconstruction from the ultrasonic phase-shift information . The other is used for measuring the ultrasonic performance . An experiment object is fixed on the steeping motor . To test the system performance , the single chip microcomputer control the movement of the object . To verify the performance of an ultrasonic vibration measurement system , a series of experiments has been designed . First experiment is to change the moving speed of the object . The second experiment is to change the sampling rate of the ultrasonic phase-shift information for reconstruction . After repeated experiments , We found the measurement error is ±0.000625% while the object moving speed is 0.8cm/sec and the sampling rate for ultrasonic phase-shift reconstruction is between 5 ~ 30 hz .
author2 Yan-Chay Li
author_facet Yan-Chay Li
Jung-Hong Lin
林俊宏
author Jung-Hong Lin
林俊宏
spellingShingle Jung-Hong Lin
林俊宏
The Implementation and Performance Test of an Ultrasonic Phase-Shift Vibration Measurement System
author_sort Jung-Hong Lin
title The Implementation and Performance Test of an Ultrasonic Phase-Shift Vibration Measurement System
title_short The Implementation and Performance Test of an Ultrasonic Phase-Shift Vibration Measurement System
title_full The Implementation and Performance Test of an Ultrasonic Phase-Shift Vibration Measurement System
title_fullStr The Implementation and Performance Test of an Ultrasonic Phase-Shift Vibration Measurement System
title_full_unstemmed The Implementation and Performance Test of an Ultrasonic Phase-Shift Vibration Measurement System
title_sort implementation and performance test of an ultrasonic phase-shift vibration measurement system
publishDate 2000
url http://ndltd.ncl.edu.tw/handle/28641120672640591502
work_keys_str_mv AT junghonglin theimplementationandperformancetestofanultrasonicphaseshiftvibrationmeasurementsystem
AT línjùnhóng theimplementationandperformancetestofanultrasonicphaseshiftvibrationmeasurementsystem
AT junghonglin gāojīngquèdùchāoyīnbōxiāngwèichàshìzhèndòngliàngcèxìtǒngzhītèxìngcèshìyǔxìtǒngshíxiàn
AT línjùnhóng gāojīngquèdùchāoyīnbōxiāngwèichàshìzhèndòngliàngcèxìtǒngzhītèxìngcèshìyǔxìtǒngshíxiàn
AT junghonglin implementationandperformancetestofanultrasonicphaseshiftvibrationmeasurementsystem
AT línjùnhóng implementationandperformancetestofanultrasonicphaseshiftvibrationmeasurementsystem
_version_ 1716833435992981504