Development of a Gas-Induced Catalytic Oxidation Reaction Process

碩士 === 元智大學 === 化學工程研究所 === 87 === In gas-liquid reacting systems, recirculation of gas from the headspace of tank back into the process liquid is required owing to the limited residence time and poor gas utilization. Commonly, methods of linking a series of tanks or using a compressor to circulate...

Full description

Bibliographic Details
Main Authors: Ching H. Wang, 王清弘
Other Authors: Sheng H. Lin
Format: Others
Language:zh-TW
Published: 1999
Online Access:http://ndltd.ncl.edu.tw/handle/15614876205079057963
id ndltd-TW-087YZU00063010
record_format oai_dc
spelling ndltd-TW-087YZU000630102015-10-13T11:50:27Z http://ndltd.ncl.edu.tw/handle/15614876205079057963 Development of a Gas-Induced Catalytic Oxidation Reaction Process 捲氣式催化氧化反應之研究 Ching H. Wang 王清弘 碩士 元智大學 化學工程研究所 87 In gas-liquid reacting systems, recirculation of gas from the headspace of tank back into the process liquid is required owing to the limited residence time and poor gas utilization. Commonly, methods of linking a series of tanks or using a compressor to circulate the unreacted gas back to the reactor were adopted to solve these problems. Recycling of unreacted gas is a importance purpose. The major purpose of this study is to improve a gas induced reactor, use the high gas utilization, both adsorption and chemical reactor can occur simultaneously on the surface of granular activated carbon(GAC) to design a new gas induced catalytic oxidation reactor. Use the new reactor to dispose of industrial wastewater and phenol. Control variables employed in the experimental investigations included the impeller speed, inlet ozone concentration, amount of GAC, ozone gas flow rate, pollutant concentration and reaction temperature, As results, increasing of GAC and inlet ozone concentration can be able to raise pollutant(COD) and phenol removal. Test results also revealed that a short period of GAC adsorption exists befor ozonation causes significant oxidation of pollutant on the GAC surfaces. Such and ozone enhanced oxidation effected an excellent regeneration of GAC and enabled GAC reuse. A maximun pollutant(COD) removal at 90 % and phenol removal at 99.5 %. Inferred the reactive organization and reactive constant from the experimental results. Kinetic studies using the observed data also showed that a short period of rapid adsorption preceded chemicial oxidation caused by ozonation, However, the combined GAC adsorption and chemical oxidation could be faithfully described by generalized and lump kinetic model. Sheng H. Lin 林勝雄 1999 學位論文 ; thesis 207 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 元智大學 === 化學工程研究所 === 87 === In gas-liquid reacting systems, recirculation of gas from the headspace of tank back into the process liquid is required owing to the limited residence time and poor gas utilization. Commonly, methods of linking a series of tanks or using a compressor to circulate the unreacted gas back to the reactor were adopted to solve these problems. Recycling of unreacted gas is a importance purpose. The major purpose of this study is to improve a gas induced reactor, use the high gas utilization, both adsorption and chemical reactor can occur simultaneously on the surface of granular activated carbon(GAC) to design a new gas induced catalytic oxidation reactor. Use the new reactor to dispose of industrial wastewater and phenol. Control variables employed in the experimental investigations included the impeller speed, inlet ozone concentration, amount of GAC, ozone gas flow rate, pollutant concentration and reaction temperature, As results, increasing of GAC and inlet ozone concentration can be able to raise pollutant(COD) and phenol removal. Test results also revealed that a short period of GAC adsorption exists befor ozonation causes significant oxidation of pollutant on the GAC surfaces. Such and ozone enhanced oxidation effected an excellent regeneration of GAC and enabled GAC reuse. A maximun pollutant(COD) removal at 90 % and phenol removal at 99.5 %. Inferred the reactive organization and reactive constant from the experimental results. Kinetic studies using the observed data also showed that a short period of rapid adsorption preceded chemicial oxidation caused by ozonation, However, the combined GAC adsorption and chemical oxidation could be faithfully described by generalized and lump kinetic model.
author2 Sheng H. Lin
author_facet Sheng H. Lin
Ching H. Wang
王清弘
author Ching H. Wang
王清弘
spellingShingle Ching H. Wang
王清弘
Development of a Gas-Induced Catalytic Oxidation Reaction Process
author_sort Ching H. Wang
title Development of a Gas-Induced Catalytic Oxidation Reaction Process
title_short Development of a Gas-Induced Catalytic Oxidation Reaction Process
title_full Development of a Gas-Induced Catalytic Oxidation Reaction Process
title_fullStr Development of a Gas-Induced Catalytic Oxidation Reaction Process
title_full_unstemmed Development of a Gas-Induced Catalytic Oxidation Reaction Process
title_sort development of a gas-induced catalytic oxidation reaction process
publishDate 1999
url http://ndltd.ncl.edu.tw/handle/15614876205079057963
work_keys_str_mv AT chinghwang developmentofagasinducedcatalyticoxidationreactionprocess
AT wángqīnghóng developmentofagasinducedcatalyticoxidationreactionprocess
AT chinghwang juǎnqìshìcuīhuàyǎnghuàfǎnyīngzhīyánjiū
AT wángqīnghóng juǎnqìshìcuīhuàyǎnghuàfǎnyīngzhīyánjiū
_version_ 1716848827486437376