碩士 === 東海大學 === 化學工程學系 === 87 === A monitoring procedure incorporating the Fourier transform technique using pulse testing to identify the maximum closed-loop log modulus (Lc,max) is presented in this study. Under an operation of closedloop control, a single pulse test in the set-point i...
Main Author: | |
---|---|
Other Authors: | |
Format: | Others |
Language: | en_US |
Published: |
1999
|
Online Access: | http://ndltd.ncl.edu.tw/handle/92939044681995575141 |
id |
ndltd-TW-087THU00063008 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-087THU000630082016-02-01T04:13:04Z http://ndltd.ncl.edu.tw/handle/92939044681995575141 An On-Line Performance Monitoring for Control Systems 控制系統執行效益之線上監視 胡啟智 碩士 東海大學 化學工程學系 87 A monitoring procedure incorporating the Fourier transform technique using pulse testing to identify the maximum closed-loop log modulus (Lc,max) is presented in this study. Under an operation of closedloop control, a single pulse test in the set-point is introduced to the system. The closed-loop transients can be numerically translated into frequency response data by Fourier integral transforms, and the Lc,max can easily be calculated using these data. The parameters of a given process model can also be obtained by a least-squares fit in frequency domain using theses data. This technique has also extended to identified a n×n MIMO system using n pulse tests. Simulation results have demonstrated that the proposed technique can yield a reliable Lc,max and be more easily implemented than those available methods in the literature. Furthermore, process identification using the Fourier transforms and optimal PID controller tuning for an open-loop unstable exothermic chemical reactor was also investigated in this study. Huang Chi-Tsung 黃琦聰 1999 學位論文 ; thesis 0 en_US |
collection |
NDLTD |
language |
en_US |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 東海大學 === 化學工程學系 === 87 === A monitoring procedure incorporating the Fourier transform technique using pulse testing to identify the maximum closed-loop log modulus (Lc,max) is presented in this study. Under an operation of closedloop control, a single pulse test in the set-point is introduced to the system. The closed-loop transients can be numerically translated into frequency response data by Fourier integral transforms, and the Lc,max can easily be calculated using these data. The parameters of a given process model can also be obtained by a least-squares fit in frequency domain using theses data. This technique has also extended to identified a n×n MIMO system using n pulse tests. Simulation results have demonstrated that the proposed technique can yield a reliable Lc,max and be more easily implemented than those available methods in the literature. Furthermore, process identification using the Fourier transforms and optimal PID controller tuning for an open-loop unstable exothermic chemical reactor was also investigated in this study.
|
author2 |
Huang Chi-Tsung |
author_facet |
Huang Chi-Tsung 胡啟智 |
author |
胡啟智 |
spellingShingle |
胡啟智 An On-Line Performance Monitoring for Control Systems |
author_sort |
胡啟智 |
title |
An On-Line Performance Monitoring for Control Systems |
title_short |
An On-Line Performance Monitoring for Control Systems |
title_full |
An On-Line Performance Monitoring for Control Systems |
title_fullStr |
An On-Line Performance Monitoring for Control Systems |
title_full_unstemmed |
An On-Line Performance Monitoring for Control Systems |
title_sort |
on-line performance monitoring for control systems |
publishDate |
1999 |
url |
http://ndltd.ncl.edu.tw/handle/92939044681995575141 |
work_keys_str_mv |
AT húqǐzhì anonlineperformancemonitoringforcontrolsystems AT húqǐzhì kòngzhìxìtǒngzhíxíngxiàoyìzhīxiànshàngjiānshì AT húqǐzhì onlineperformancemonitoringforcontrolsystems |
_version_ |
1718175535718203392 |