Design and Implementation of Single-Phase Shunt Active Power Line Conditioners
碩士 === 國立臺灣科技大學 === 電子工程系 === 87 === The power factor correction has been an important issue of the power electronics application in recent years. The purpose of the correction is to shape the source-side current to be sinusoidal and in phase with the source voltage. There are two types of correct...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | zh-TW |
Published: |
1999
|
Online Access: | http://ndltd.ncl.edu.tw/handle/44367925581019948519 |
id |
ndltd-TW-087NTUST428017 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-087NTUST4280172016-02-01T04:12:44Z http://ndltd.ncl.edu.tw/handle/44367925581019948519 Design and Implementation of Single-Phase Shunt Active Power Line Conditioners 單相並聯式主動型電力濾波器之研製 Kuo, Lian-Chen 郭兩成 碩士 國立臺灣科技大學 電子工程系 87 The power factor correction has been an important issue of the power electronics application in recent years. The purpose of the correction is to shape the source-side current to be sinusoidal and in phase with the source voltage. There are two types of correction technologies. The first one is to insert a power factor corrector (PFC) in series between the power source and the load. The second one is to inject harmonic currents into the system by a shunt active power line conditioner (APLC). The main topic of this thesis is to develop new control strategies for the APLC. We will introduce the circuit structure and operating principles of the single-phase APLC first. Then three control methods are presented and discussed in detail. According to the design procedures, prototype systems are implemented and the experimental results show feasibility of the proposed methods. Lo, Yu-Kang 羅有綱 1999 學位論文 ; thesis 72 zh-TW |
collection |
NDLTD |
language |
zh-TW |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 國立臺灣科技大學 === 電子工程系 === 87 === The power factor correction has been an important issue of the power electronics application in recent years. The purpose of the correction is to shape the source-side current to be sinusoidal and in phase with the source voltage. There are two types of correction technologies. The first one is to insert a power factor corrector (PFC) in series between the power source and the load. The second one is to inject harmonic currents into the system by a shunt active power line conditioner (APLC). The main topic of this thesis is to develop new control strategies for the APLC.
We will introduce the circuit structure and operating principles of the single-phase APLC first. Then three control methods are presented and discussed in detail. According to the design procedures, prototype systems are implemented and the experimental results show feasibility of the proposed methods.
|
author2 |
Lo, Yu-Kang |
author_facet |
Lo, Yu-Kang Kuo, Lian-Chen 郭兩成 |
author |
Kuo, Lian-Chen 郭兩成 |
spellingShingle |
Kuo, Lian-Chen 郭兩成 Design and Implementation of Single-Phase Shunt Active Power Line Conditioners |
author_sort |
Kuo, Lian-Chen |
title |
Design and Implementation of Single-Phase Shunt Active Power Line Conditioners |
title_short |
Design and Implementation of Single-Phase Shunt Active Power Line Conditioners |
title_full |
Design and Implementation of Single-Phase Shunt Active Power Line Conditioners |
title_fullStr |
Design and Implementation of Single-Phase Shunt Active Power Line Conditioners |
title_full_unstemmed |
Design and Implementation of Single-Phase Shunt Active Power Line Conditioners |
title_sort |
design and implementation of single-phase shunt active power line conditioners |
publishDate |
1999 |
url |
http://ndltd.ncl.edu.tw/handle/44367925581019948519 |
work_keys_str_mv |
AT kuolianchen designandimplementationofsinglephaseshuntactivepowerlineconditioners AT guōliǎngchéng designandimplementationofsinglephaseshuntactivepowerlineconditioners AT kuolianchen dānxiāngbìngliánshìzhǔdòngxíngdiànlìlǜbōqìzhīyánzhì AT guōliǎngchéng dānxiāngbìngliánshìzhǔdòngxíngdiànlìlǜbōqìzhīyánzhì |
_version_ |
1718175000304812032 |