Design and Implementation of Single-Phase Shunt Active Power Line Conditioners

碩士 === 國立臺灣科技大學 === 電子工程系 === 87 ===   The power factor correction has been an important issue of the power electronics application in recent years. The purpose of the correction is to shape the source-side current to be sinusoidal and in phase with the source voltage. There are two types of correct...

Full description

Bibliographic Details
Main Authors: Kuo, Lian-Chen, 郭兩成
Other Authors: Lo, Yu-Kang
Format: Others
Language:zh-TW
Published: 1999
Online Access:http://ndltd.ncl.edu.tw/handle/44367925581019948519
id ndltd-TW-087NTUST428017
record_format oai_dc
spelling ndltd-TW-087NTUST4280172016-02-01T04:12:44Z http://ndltd.ncl.edu.tw/handle/44367925581019948519 Design and Implementation of Single-Phase Shunt Active Power Line Conditioners 單相並聯式主動型電力濾波器之研製 Kuo, Lian-Chen 郭兩成 碩士 國立臺灣科技大學 電子工程系 87   The power factor correction has been an important issue of the power electronics application in recent years. The purpose of the correction is to shape the source-side current to be sinusoidal and in phase with the source voltage. There are two types of correction technologies. The first one is to insert a power factor corrector (PFC) in series between the power source and the load. The second one is to inject harmonic currents into the system by a shunt active power line conditioner (APLC). The main topic of this thesis is to develop new control strategies for the APLC.   We will introduce the circuit structure and operating principles of the single-phase APLC first. Then three control methods are presented and discussed in detail. According to the design procedures, prototype systems are implemented and the experimental results show feasibility of the proposed methods. Lo, Yu-Kang 羅有綱 1999 學位論文 ; thesis 72 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立臺灣科技大學 === 電子工程系 === 87 ===   The power factor correction has been an important issue of the power electronics application in recent years. The purpose of the correction is to shape the source-side current to be sinusoidal and in phase with the source voltage. There are two types of correction technologies. The first one is to insert a power factor corrector (PFC) in series between the power source and the load. The second one is to inject harmonic currents into the system by a shunt active power line conditioner (APLC). The main topic of this thesis is to develop new control strategies for the APLC.   We will introduce the circuit structure and operating principles of the single-phase APLC first. Then three control methods are presented and discussed in detail. According to the design procedures, prototype systems are implemented and the experimental results show feasibility of the proposed methods.
author2 Lo, Yu-Kang
author_facet Lo, Yu-Kang
Kuo, Lian-Chen
郭兩成
author Kuo, Lian-Chen
郭兩成
spellingShingle Kuo, Lian-Chen
郭兩成
Design and Implementation of Single-Phase Shunt Active Power Line Conditioners
author_sort Kuo, Lian-Chen
title Design and Implementation of Single-Phase Shunt Active Power Line Conditioners
title_short Design and Implementation of Single-Phase Shunt Active Power Line Conditioners
title_full Design and Implementation of Single-Phase Shunt Active Power Line Conditioners
title_fullStr Design and Implementation of Single-Phase Shunt Active Power Line Conditioners
title_full_unstemmed Design and Implementation of Single-Phase Shunt Active Power Line Conditioners
title_sort design and implementation of single-phase shunt active power line conditioners
publishDate 1999
url http://ndltd.ncl.edu.tw/handle/44367925581019948519
work_keys_str_mv AT kuolianchen designandimplementationofsinglephaseshuntactivepowerlineconditioners
AT guōliǎngchéng designandimplementationofsinglephaseshuntactivepowerlineconditioners
AT kuolianchen dānxiāngbìngliánshìzhǔdòngxíngdiànlìlǜbōqìzhīyánzhì
AT guōliǎngchéng dānxiāngbìngliánshìzhǔdòngxíngdiànlìlǜbōqìzhīyánzhì
_version_ 1718175000304812032