Study on the detection of superoxide anion using mixed-valence complex modified electrode

碩士 === 國立臺灣師範大學 === 化學研究所 === 87 === Superoxide anion radical (O2-) has received a great deal attention in the fields of biochemistry, medicine and environment. Mixed-valence complex (Prussian Blue and ruthenium(II) hexacyanoferrate ) modified electrodes are investigated for the detection of superox...

Full description

Bibliographic Details
Main Authors: Chih-Liang Kao, 高智亮
Other Authors: Ru-Jang Lin
Format: Others
Language:zh-TW
Published: 1999
Online Access:http://ndltd.ncl.edu.tw/handle/28114259126306031441
id ndltd-TW-087NTNU0065019
record_format oai_dc
spelling ndltd-TW-087NTNU00650192015-10-13T11:46:56Z http://ndltd.ncl.edu.tw/handle/28114259126306031441 Study on the detection of superoxide anion using mixed-valence complex modified electrode 混合價錯合物修飾電極在感測超氧陰離子的研究 Chih-Liang Kao 高智亮 碩士 國立臺灣師範大學 化學研究所 87 Superoxide anion radical (O2-) has received a great deal attention in the fields of biochemistry, medicine and environment. Mixed-valence complex (Prussian Blue and ruthenium(II) hexacyanoferrate ) modified electrodes are investigated for the detection of superoxide anion radical in this study. The superoxide anion radical amperometric sensors were made by poly(o-phenylenediamine) (PPD) electrodeposition onto Prussian Blue (PB) modified electrode and ruthenium(II) hexacyanoferrate (RuHCF) modified electrode. O2- was generated by Xanthine-Xanthine Oxidase system. The interference of ascoribic acid can be avoided with PPD/RuHCF/GC but PPD/PB/GC. The PPD/RuHCF/GC response exhibited a linear dependence on analytic concentration of xanthine in the range 5*10-5~9.5*10-4 M (O2- concentration 2.9*10-7~5.5*10-6 M). Ru-Jang Lin 林如章 1999 學位論文 ; thesis 0 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立臺灣師範大學 === 化學研究所 === 87 === Superoxide anion radical (O2-) has received a great deal attention in the fields of biochemistry, medicine and environment. Mixed-valence complex (Prussian Blue and ruthenium(II) hexacyanoferrate ) modified electrodes are investigated for the detection of superoxide anion radical in this study. The superoxide anion radical amperometric sensors were made by poly(o-phenylenediamine) (PPD) electrodeposition onto Prussian Blue (PB) modified electrode and ruthenium(II) hexacyanoferrate (RuHCF) modified electrode. O2- was generated by Xanthine-Xanthine Oxidase system. The interference of ascoribic acid can be avoided with PPD/RuHCF/GC but PPD/PB/GC. The PPD/RuHCF/GC response exhibited a linear dependence on analytic concentration of xanthine in the range 5*10-5~9.5*10-4 M (O2- concentration 2.9*10-7~5.5*10-6 M).
author2 Ru-Jang Lin
author_facet Ru-Jang Lin
Chih-Liang Kao
高智亮
author Chih-Liang Kao
高智亮
spellingShingle Chih-Liang Kao
高智亮
Study on the detection of superoxide anion using mixed-valence complex modified electrode
author_sort Chih-Liang Kao
title Study on the detection of superoxide anion using mixed-valence complex modified electrode
title_short Study on the detection of superoxide anion using mixed-valence complex modified electrode
title_full Study on the detection of superoxide anion using mixed-valence complex modified electrode
title_fullStr Study on the detection of superoxide anion using mixed-valence complex modified electrode
title_full_unstemmed Study on the detection of superoxide anion using mixed-valence complex modified electrode
title_sort study on the detection of superoxide anion using mixed-valence complex modified electrode
publishDate 1999
url http://ndltd.ncl.edu.tw/handle/28114259126306031441
work_keys_str_mv AT chihliangkao studyonthedetectionofsuperoxideanionusingmixedvalencecomplexmodifiedelectrode
AT gāozhìliàng studyonthedetectionofsuperoxideanionusingmixedvalencecomplexmodifiedelectrode
AT chihliangkao hùnhéjiàcuòhéwùxiūshìdiànjízàigǎncèchāoyǎngyīnlízideyánjiū
AT gāozhìliàng hùnhéjiàcuòhéwùxiūshìdiànjízàigǎncèchāoyǎngyīnlízideyánjiū
_version_ 1716848311739088896