The research and development of high performance multi-bent evaporator in air conditioning unit
碩士 === 國立成功大學 === 機械工程學系 === 87 === There are two parts in this paper. For the first part, an induced wind tunnel was used to measure the thermal-hydraulic characteristics of multi-bent evaporator for different fin shapes (louver, wavy fins), different fin pitches( 18,20 and 22 fins per i...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | zh-TW |
Published: |
1999
|
Online Access: | http://ndltd.ncl.edu.tw/handle/57987527324040960944 |
id |
ndltd-TW-087NCKU0489020 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-087NCKU04890202016-07-11T04:13:32Z http://ndltd.ncl.edu.tw/handle/57987527324040960944 The research and development of high performance multi-bent evaporator in air conditioning unit 空調用高效率多面式蒸發器之研發及測試 FU-SHIUNG SHIH 施富雄 碩士 國立成功大學 機械工程學系 87 There are two parts in this paper. For the first part, an induced wind tunnel was used to measure the thermal-hydraulic characteristics of multi-bent evaporator for different fin shapes (louver, wavy fins), different fin pitches( 18,20 and 22 fins per inch) . The second part of this paper was to develop an air conditioning unit with cooling capacity of 4000kcal/hr and Energy Efficiency Ratio (EER) of 2.5 kcal/hr.w. ﹙1﹚ The first part of this paper: Measurements were made for the air frontal velocity ranging from 0.8 m/s ~ 4.5 m/s , while the water inlet temperature and flow rate were maintained at 70℃ , 6 L/min for the dry coils and at 10℃ , 6 L/min for the wet coils , respectively. The experimental results indicated that , louver fins have higher Colburn and friction factors compared to the wavy fins. ﹙2﹚ The second part of this paper: The performances of an air-conditioning unit were measured in an environmental-controlled chamber. The refrigerant in the tube side is R22. It is found that to get a cooling capacity of 4000kcal/hr and EER of 2.5 kcal/hr.w, one must uses louver fin with fin pitch 18fins/inch, the capillary tube with diameterψ1.7mm and length 600mm, and the R22 filling mass of 1100g. JIN-YUH JANG 張錦裕 1999 學位論文 ; thesis 0 zh-TW |
collection |
NDLTD |
language |
zh-TW |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 國立成功大學 === 機械工程學系 === 87 === There are two parts in this paper. For the first part, an induced wind tunnel was used to measure the thermal-hydraulic characteristics of multi-bent evaporator for different fin shapes (louver, wavy fins), different fin pitches( 18,20 and 22 fins per inch) . The second part of this paper was to develop an air conditioning unit with cooling capacity of 4000kcal/hr and Energy Efficiency Ratio (EER) of 2.5 kcal/hr.w.
﹙1﹚ The first part of this paper: Measurements were made for the air frontal velocity ranging from 0.8 m/s ~ 4.5 m/s , while the water inlet temperature and flow rate were maintained at 70℃ , 6 L/min for the dry coils and at 10℃ , 6 L/min for the wet coils , respectively. The experimental results indicated that , louver fins have higher Colburn and friction factors compared to the wavy fins.
﹙2﹚ The second part of this paper: The performances of an air-conditioning unit were measured in an environmental-controlled chamber. The refrigerant in the tube side is R22. It is found that to get a cooling capacity of 4000kcal/hr and EER of 2.5 kcal/hr.w, one must uses louver fin with fin pitch 18fins/inch, the capillary tube with diameterψ1.7mm and length 600mm, and the R22 filling mass of 1100g.
|
author2 |
JIN-YUH JANG |
author_facet |
JIN-YUH JANG FU-SHIUNG SHIH 施富雄 |
author |
FU-SHIUNG SHIH 施富雄 |
spellingShingle |
FU-SHIUNG SHIH 施富雄 The research and development of high performance multi-bent evaporator in air conditioning unit |
author_sort |
FU-SHIUNG SHIH |
title |
The research and development of high performance multi-bent evaporator in air conditioning unit |
title_short |
The research and development of high performance multi-bent evaporator in air conditioning unit |
title_full |
The research and development of high performance multi-bent evaporator in air conditioning unit |
title_fullStr |
The research and development of high performance multi-bent evaporator in air conditioning unit |
title_full_unstemmed |
The research and development of high performance multi-bent evaporator in air conditioning unit |
title_sort |
research and development of high performance multi-bent evaporator in air conditioning unit |
publishDate |
1999 |
url |
http://ndltd.ncl.edu.tw/handle/57987527324040960944 |
work_keys_str_mv |
AT fushiungshih theresearchanddevelopmentofhighperformancemultibentevaporatorinairconditioningunit AT shīfùxióng theresearchanddevelopmentofhighperformancemultibentevaporatorinairconditioningunit AT fushiungshih kōngdiàoyònggāoxiàolǜduōmiànshìzhēngfāqìzhīyánfājícèshì AT shīfùxióng kōngdiàoyònggāoxiàolǜduōmiànshìzhēngfāqìzhīyánfājícèshì AT fushiungshih researchanddevelopmentofhighperformancemultibentevaporatorinairconditioningunit AT shīfùxióng researchanddevelopmentofhighperformancemultibentevaporatorinairconditioningunit |
_version_ |
1718342193299587072 |