The Study of Passive Flow Control Devices Performance at Low Inlet Subcooling

碩士 === 國立雲林科技大學 === 機械工程技術研究所 === 86 === When the cavitating venturi (CV) operates at low value of inlet subcooling to conserve electrical power, an all-liquid overflow phenomenon can be occurred. It is the objective of this study to evaluate some alternatives of CV,such as orifice, nozz...

Full description

Bibliographic Details
Main Authors: Chang Shuo-Kai, 張碩凱
Other Authors: Chen Ing-yung
Format: Others
Language:zh-TW
Published: 1998
Online Access:http://ndltd.ncl.edu.tw/handle/93042251109131684647
id ndltd-TW-086YUNTE488001
record_format oai_dc
spelling ndltd-TW-086YUNTE4880012015-10-13T17:34:50Z http://ndltd.ncl.edu.tw/handle/93042251109131684647 The Study of Passive Flow Control Devices Performance at Low Inlet Subcooling 被動式流量控制裝置在低進口過冷度下之性能研究 Chang Shuo-Kai 張碩凱 碩士 國立雲林科技大學 機械工程技術研究所 86 When the cavitating venturi (CV) operates at low value of inlet subcooling to conserve electrical power, an all-liquid overflow phenomenon can be occurred. It is the objective of this study to evaluate some alternatives of CV,such as orifice, nozzle and capillary tube. Experiments at different levels of inlet subcooling were performed and the phenomena relevant to different operation parameters were explored. The test results of all these PFCDs (Passive Flow Control Devices) will be compared with the CV's performance. Chen Ing-yung Liou Shiuh-guang 陳英洋 劉旭光 1998 學位論文 ; thesis 0 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立雲林科技大學 === 機械工程技術研究所 === 86 === When the cavitating venturi (CV) operates at low value of inlet subcooling to conserve electrical power, an all-liquid overflow phenomenon can be occurred. It is the objective of this study to evaluate some alternatives of CV,such as orifice, nozzle and capillary tube. Experiments at different levels of inlet subcooling were performed and the phenomena relevant to different operation parameters were explored. The test results of all these PFCDs (Passive Flow Control Devices) will be compared with the CV's performance.
author2 Chen Ing-yung
author_facet Chen Ing-yung
Chang Shuo-Kai
張碩凱
author Chang Shuo-Kai
張碩凱
spellingShingle Chang Shuo-Kai
張碩凱
The Study of Passive Flow Control Devices Performance at Low Inlet Subcooling
author_sort Chang Shuo-Kai
title The Study of Passive Flow Control Devices Performance at Low Inlet Subcooling
title_short The Study of Passive Flow Control Devices Performance at Low Inlet Subcooling
title_full The Study of Passive Flow Control Devices Performance at Low Inlet Subcooling
title_fullStr The Study of Passive Flow Control Devices Performance at Low Inlet Subcooling
title_full_unstemmed The Study of Passive Flow Control Devices Performance at Low Inlet Subcooling
title_sort study of passive flow control devices performance at low inlet subcooling
publishDate 1998
url http://ndltd.ncl.edu.tw/handle/93042251109131684647
work_keys_str_mv AT changshuokai thestudyofpassiveflowcontroldevicesperformanceatlowinletsubcooling
AT zhāngshuòkǎi thestudyofpassiveflowcontroldevicesperformanceatlowinletsubcooling
AT changshuokai bèidòngshìliúliàngkòngzhìzhuāngzhìzàidījìnkǒuguòlěngdùxiàzhīxìngnéngyánjiū
AT zhāngshuòkǎi bèidòngshìliúliàngkòngzhìzhuāngzhìzàidījìnkǒuguòlěngdùxiàzhīxìngnéngyánjiū
AT changshuokai studyofpassiveflowcontroldevicesperformanceatlowinletsubcooling
AT zhāngshuòkǎi studyofpassiveflowcontroldevicesperformanceatlowinletsubcooling
_version_ 1717781634801991680