A Study on the Determination of Arsenic(III) and Arsenic(V) in Drinking Water and Arsenic(III) in Air by Graphite-Furnace Atomic Absorption Spectrophotometry
碩士 === 東海大學 === 環境科學系 === 86 === Arsenic(III) (12.5-200 ng) in drinking water (25 mL) reacted with 2,3-dimercaptopropane-1-sulfonate (DMPS,0.6 mg) in ammonium acetatebuffer (2.0 mmol, pH=5.5) and formed a complex of As(III)-DMPS. Thecomplex was concentrated on two Sep-Pak C18 cartridges in series an...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | zh-TW |
Published: |
1998
|
Online Access: | http://ndltd.ncl.edu.tw/handle/65425009911038954192 |
id |
ndltd-TW-086THU00518007 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-086THU005180072015-10-13T17:34:44Z http://ndltd.ncl.edu.tw/handle/65425009911038954192 A Study on the Determination of Arsenic(III) and Arsenic(V) in Drinking Water and Arsenic(III) in Air by Graphite-Furnace Atomic Absorption Spectrophotometry 以石墨電熱式原子吸光法測定飲用水中As(III),As(V)和空氣中As(III)之研究 Hsieh,Chuan-Jier 謝傳傑 碩士 東海大學 環境科學系 86 Arsenic(III) (12.5-200 ng) in drinking water (25 mL) reacted with 2,3-dimercaptopropane-1-sulfonate (DMPS,0.6 mg) in ammonium acetatebuffer (2.0 mmol, pH=5.5) and formed a complex of As(III)-DMPS. Thecomplex was concentrated on two Sep-Pak C18 cartridges in series and each cartridge was eluted with methanol and adjusted to 2.00 mL. After additionof 2.0 mg of Ni(II), a portion(20 mL) of the mixture was introduced into a graphite cuvette and was atomized according to a temperature program.The method detection limit (3s) was 0.11*0.01(mg/L) and the calibration graph was linear up to 8.00(mg/L) . Accuracies of 97.6-98.9% wereobtained when testing a QC (Strem Chem. Inc.) sample. Arsenic(V) (up to 100 ng) in drinking water was reduced to As(III) with L-cysteine(0.5 mL, 1.0% in HNO3 (0.2%,v/v)) prior to the formation of As(III)-DMPS complex. Accuracies of 98.5-99.3% were obtained with RSD of 2.5% by testing a SRM 1643d and a QC sample(HPS#290608). The proposed method could be applied to the determination of Arsenic(III) vapor in airwith a detection limit of 2.8 ng.-1 -aA Study on the Determination of Arsenic(III) and Arsenic(V) in Drinking Water and Arsenic(III) in Air by Graphite-Furnace Atomic Absorption Spectrophotometry 郭茂松 鄭政峰 葉玉堂 蔡素珍 1998 學位論文 ; thesis 97 zh-TW |
collection |
NDLTD |
language |
zh-TW |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 東海大學 === 環境科學系 === 86 === Arsenic(III) (12.5-200 ng) in drinking water (25 mL) reacted with 2,3-dimercaptopropane-1-sulfonate (DMPS,0.6 mg) in ammonium acetatebuffer (2.0 mmol, pH=5.5) and formed a complex of As(III)-DMPS. Thecomplex was concentrated on two Sep-Pak C18 cartridges in series and each cartridge was eluted with methanol and adjusted to 2.00 mL. After additionof 2.0 mg of Ni(II), a portion(20 mL) of the mixture was introduced into a graphite cuvette and was atomized according to a temperature program.The method detection limit (3s) was 0.11*0.01(mg/L) and the calibration graph was linear up to 8.00(mg/L) . Accuracies of 97.6-98.9% wereobtained when testing a QC (Strem Chem. Inc.) sample. Arsenic(V) (up to 100 ng) in drinking water was reduced to As(III) with L-cysteine(0.5 mL, 1.0% in HNO3 (0.2%,v/v)) prior to the formation of As(III)-DMPS complex. Accuracies of 98.5-99.3% were obtained with RSD of 2.5% by testing a SRM 1643d and a QC sample(HPS#290608). The proposed method could be applied to the determination of Arsenic(III) vapor in airwith a detection limit of 2.8 ng.-1 -aA Study on the Determination of Arsenic(III) and Arsenic(V) in Drinking Water and Arsenic(III) in Air by Graphite-Furnace Atomic Absorption Spectrophotometry
|
author2 |
郭茂松 |
author_facet |
郭茂松 Hsieh,Chuan-Jier 謝傳傑 |
author |
Hsieh,Chuan-Jier 謝傳傑 |
spellingShingle |
Hsieh,Chuan-Jier 謝傳傑 A Study on the Determination of Arsenic(III) and Arsenic(V) in Drinking Water and Arsenic(III) in Air by Graphite-Furnace Atomic Absorption Spectrophotometry |
author_sort |
Hsieh,Chuan-Jier |
title |
A Study on the Determination of Arsenic(III) and Arsenic(V) in Drinking Water and Arsenic(III) in Air by Graphite-Furnace Atomic Absorption Spectrophotometry |
title_short |
A Study on the Determination of Arsenic(III) and Arsenic(V) in Drinking Water and Arsenic(III) in Air by Graphite-Furnace Atomic Absorption Spectrophotometry |
title_full |
A Study on the Determination of Arsenic(III) and Arsenic(V) in Drinking Water and Arsenic(III) in Air by Graphite-Furnace Atomic Absorption Spectrophotometry |
title_fullStr |
A Study on the Determination of Arsenic(III) and Arsenic(V) in Drinking Water and Arsenic(III) in Air by Graphite-Furnace Atomic Absorption Spectrophotometry |
title_full_unstemmed |
A Study on the Determination of Arsenic(III) and Arsenic(V) in Drinking Water and Arsenic(III) in Air by Graphite-Furnace Atomic Absorption Spectrophotometry |
title_sort |
study on the determination of arsenic(iii) and arsenic(v) in drinking water and arsenic(iii) in air by graphite-furnace atomic absorption spectrophotometry |
publishDate |
1998 |
url |
http://ndltd.ncl.edu.tw/handle/65425009911038954192 |
work_keys_str_mv |
AT hsiehchuanjier astudyonthedeterminationofarseniciiiandarsenicvindrinkingwaterandarseniciiiinairbygraphitefurnaceatomicabsorptionspectrophotometry AT xièchuánjié astudyonthedeterminationofarseniciiiandarsenicvindrinkingwaterandarseniciiiinairbygraphitefurnaceatomicabsorptionspectrophotometry AT hsiehchuanjier yǐshímòdiànrèshìyuánzixīguāngfǎcèdìngyǐnyòngshuǐzhōngasiiiasvhékōngqìzhōngasiiizhīyánjiū AT xièchuánjié yǐshímòdiànrèshìyuánzixīguāngfǎcèdìngyǐnyòngshuǐzhōngasiiiasvhékōngqìzhōngasiiizhīyánjiū AT hsiehchuanjier studyonthedeterminationofarseniciiiandarsenicvindrinkingwaterandarseniciiiinairbygraphitefurnaceatomicabsorptionspectrophotometry AT xièchuánjié studyonthedeterminationofarseniciiiandarsenicvindrinkingwaterandarseniciiiinairbygraphitefurnaceatomicabsorptionspectrophotometry |
_version_ |
1717781003278221312 |