Two-dimensional Measurment for Evaluating Finger Motion
碩士 === 國立成功大學 === 醫學工程學系 === 86 === We evaluate the finger motor function by measuring the area of the range of motion of fingers from using a 3-dimensional motion analysis system. The purposes of this study are 1) to test reliability and repeatability of...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | zh-TW |
Published: |
1997
|
Online Access: | http://ndltd.ncl.edu.tw/handle/04512121781010081522 |
id |
ndltd-TW-086NCKU1530011 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-086NCKU15300112015-10-13T11:06:14Z http://ndltd.ncl.edu.tw/handle/04512121781010081522 Two-dimensional Measurment for Evaluating Finger Motion 手指運動的二維衡量法 Lin, Pey-Chung 林沛中 碩士 國立成功大學 醫學工程學系 86 We evaluate the finger motor function by measuring the area of the range of motion of fingers from using a 3-dimensional motion analysis system. The purposes of this study are 1) to test reliability and repeatability of the area measurement of normal subjects, 2) to establish a fingertip motion areadatabase of normal subjects, and 3) to clinicallyevaluate the impairment of fingers for patients. Ten health subjects had been tested by repeatedmeasurements three times, once in a week and last for three weeks. The between-week ICC was 0.94. Thewithin-week ICC was from 0.92 to 0.94. This resultmeant excellent reliability in our test. Normal data base was established from twenty health subjects.By 3-way ANOVA, there is no interaction in sex, hand and finger. And there are no significant differences in male/ female, left/right hand and different fingers. So, we used non- linear regression to calculate regressive function between finger length and area. This result is Area=0.677*length2. After evaluating twenty patients, there is high correlation, R=0.889, between our method with AMA(American Medical Association) standard. Our method for evaluation of finger motor functionmaybe better than others. The main reason is that a large area of fingertip motion includes not only larger range of finger joint angles, but also better coordination of finger joints. Su Fong-Chin, Chiu Haw-Yeu 蘇芳慶, 邱浩遠 1997 學位論文 ; thesis 51 zh-TW |
collection |
NDLTD |
language |
zh-TW |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 國立成功大學 === 醫學工程學系 === 86 === We evaluate the finger motor function by measuring the area
of the range of motion of fingers from using a 3-dimensional
motion analysis system. The purposes of this study are 1) to
test reliability and repeatability of the area measurement of
normal subjects, 2) to establish a fingertip motion areadatabase
of normal subjects, and 3) to clinicallyevaluate the impairment
of fingers for patients. Ten health subjects had been tested
by repeatedmeasurements three times, once in a week and last for
three weeks. The between-week ICC was 0.94. Thewithin-week ICC
was from 0.92 to 0.94. This resultmeant excellent reliability in
our test. Normal data base was established from twenty health
subjects.By 3-way ANOVA, there is no interaction in sex, hand
and finger. And there are no significant differences in male/
female, left/right hand and different fingers. So, we used non-
linear regression to calculate regressive function between
finger length and area. This result is Area=0.677*length2. After
evaluating twenty patients, there is high correlation, R=0.889,
between our method with AMA(American Medical Association)
standard. Our method for evaluation of finger motor
functionmaybe better than others. The main reason is that a
large area of fingertip motion includes not only larger range of
finger joint angles, but also better coordination of finger
joints.
|
author2 |
Su Fong-Chin, Chiu Haw-Yeu |
author_facet |
Su Fong-Chin, Chiu Haw-Yeu Lin, Pey-Chung 林沛中 |
author |
Lin, Pey-Chung 林沛中 |
spellingShingle |
Lin, Pey-Chung 林沛中 Two-dimensional Measurment for Evaluating Finger Motion |
author_sort |
Lin, Pey-Chung |
title |
Two-dimensional Measurment for Evaluating Finger Motion |
title_short |
Two-dimensional Measurment for Evaluating Finger Motion |
title_full |
Two-dimensional Measurment for Evaluating Finger Motion |
title_fullStr |
Two-dimensional Measurment for Evaluating Finger Motion |
title_full_unstemmed |
Two-dimensional Measurment for Evaluating Finger Motion |
title_sort |
two-dimensional measurment for evaluating finger motion |
publishDate |
1997 |
url |
http://ndltd.ncl.edu.tw/handle/04512121781010081522 |
work_keys_str_mv |
AT linpeychung twodimensionalmeasurmentforevaluatingfingermotion AT línpèizhōng twodimensionalmeasurmentforevaluatingfingermotion AT linpeychung shǒuzhǐyùndòngdeèrwéihéngliàngfǎ AT línpèizhōng shǒuzhǐyùndòngdeèrwéihéngliàngfǎ |
_version_ |
1716836894948458496 |