Effect of Panel Angles for the Nursing Hand Controls Performance in Emergency Surgery

碩士 === 國立成功大學 === 工業設計學系 === 86 === Abstract Due to frequent interaction between nursing staff of emergency medical surgery and medical implements, operation between hands and controls in particular, is the most crucial point in the whol...

Full description

Bibliographic Details
Main Authors: wu, chi-yung, 吳啟永
Other Authors: Fong-Kong Wu
Format: Others
Language:zh-TW
Published: 1998
Online Access:http://ndltd.ncl.edu.tw/handle/39348326985302296752
id ndltd-TW-086NCKU1038011
record_format oai_dc
spelling ndltd-TW-086NCKU10380112015-10-13T11:06:11Z http://ndltd.ncl.edu.tw/handle/39348326985302296752 Effect of Panel Angles for the Nursing Hand Controls Performance in Emergency Surgery 急診外科護理人員對醫療儀器之手用控制器型態與面板角度操作關係研究 wu, chi-yung 吳啟永 碩士 國立成功大學 工業設計學系 86 Abstract Due to frequent interaction between nursing staff of emergency medical surgery and medical implements, operation between hands and controls in particular, is the most crucial point in the whole process of emergency surgery. Hence, postponed operation of medical implements or false use of operation of implement may lead to deprivation of part of patient's physical function. The report chiefly discusses how panel angle and height are related to comfort brought during operation in order to offer nursing and normal staff better efficiency. Besides, it is advisable for medical product designer to efficiently adopt the figure as reference for designing implement such as panel angle and height. There are two main approaches toward researching the experiment, motive operation of hand track and experiment of subjective operation, are tested on ten nursing and normal staffs of emergency surgery respectively. Test samples are all female with no disease in their right hands. Analyzing operation of three controls (fractional rotation knob, push button, toggle switch), five panel angles (0 degree, 10 degree, 20 degree, 30 degree, 40 degree), five motive tracks of hand operation (87cm, 90cm, 93cm, 96c1. It is preferable for nursing staff to operate panel angle of controls, fractional rotation knob, push button and toggle switch, of 10-20 degree respectively. The greater height is of 90cm to 93cm.2. Normal staff is advised to operate panel angle of controls, fractional rotation knob, push button and toggle switch, of 10-20 degree respectively. The greater height is of 90-93cm save that of toggle switch is of 87-90cm.Keyword: ergonomic design, emergency surgery, hand motive track, evaluation of subjective operation Fong-Kong Wu 吳豐光 1998 學位論文 ; thesis 206 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立成功大學 === 工業設計學系 === 86 === Abstract Due to frequent interaction between nursing staff of emergency medical surgery and medical implements, operation between hands and controls in particular, is the most crucial point in the whole process of emergency surgery. Hence, postponed operation of medical implements or false use of operation of implement may lead to deprivation of part of patient's physical function. The report chiefly discusses how panel angle and height are related to comfort brought during operation in order to offer nursing and normal staff better efficiency. Besides, it is advisable for medical product designer to efficiently adopt the figure as reference for designing implement such as panel angle and height. There are two main approaches toward researching the experiment, motive operation of hand track and experiment of subjective operation, are tested on ten nursing and normal staffs of emergency surgery respectively. Test samples are all female with no disease in their right hands. Analyzing operation of three controls (fractional rotation knob, push button, toggle switch), five panel angles (0 degree, 10 degree, 20 degree, 30 degree, 40 degree), five motive tracks of hand operation (87cm, 90cm, 93cm, 96c1. It is preferable for nursing staff to operate panel angle of controls, fractional rotation knob, push button and toggle switch, of 10-20 degree respectively. The greater height is of 90cm to 93cm.2. Normal staff is advised to operate panel angle of controls, fractional rotation knob, push button and toggle switch, of 10-20 degree respectively. The greater height is of 90-93cm save that of toggle switch is of 87-90cm.Keyword: ergonomic design, emergency surgery, hand motive track, evaluation of subjective operation
author2 Fong-Kong Wu
author_facet Fong-Kong Wu
wu, chi-yung
吳啟永
author wu, chi-yung
吳啟永
spellingShingle wu, chi-yung
吳啟永
Effect of Panel Angles for the Nursing Hand Controls Performance in Emergency Surgery
author_sort wu, chi-yung
title Effect of Panel Angles for the Nursing Hand Controls Performance in Emergency Surgery
title_short Effect of Panel Angles for the Nursing Hand Controls Performance in Emergency Surgery
title_full Effect of Panel Angles for the Nursing Hand Controls Performance in Emergency Surgery
title_fullStr Effect of Panel Angles for the Nursing Hand Controls Performance in Emergency Surgery
title_full_unstemmed Effect of Panel Angles for the Nursing Hand Controls Performance in Emergency Surgery
title_sort effect of panel angles for the nursing hand controls performance in emergency surgery
publishDate 1998
url http://ndltd.ncl.edu.tw/handle/39348326985302296752
work_keys_str_mv AT wuchiyung effectofpanelanglesforthenursinghandcontrolsperformanceinemergencysurgery
AT wúqǐyǒng effectofpanelanglesforthenursinghandcontrolsperformanceinemergencysurgery
AT wuchiyung jízhěnwàikēhùlǐrényuánduìyīliáoyíqìzhīshǒuyòngkòngzhìqìxíngtàiyǔmiànbǎnjiǎodùcāozuòguānxìyánjiū
AT wúqǐyǒng jízhěnwàikēhùlǐrényuánduìyīliáoyíqìzhīshǒuyòngkòngzhìqìxíngtàiyǔmiànbǎnjiǎodùcāozuòguānxìyánjiū
_version_ 1716836397342523392