Development of a Cardiac Output Measurement System using Thoracic Bioimpedance

碩士 === 國立臺灣大學 === 電機工程學系 === 85 === The research project is to use the bioelectric impedance measurement technique that is applied to measure the most important physilogical parameters of the cardiac-pulmonary organs, such as heart rate...

Full description

Bibliographic Details
Main Authors: Kao, Hau-ping, 高浩平
Other Authors: Jin-Fu Chang
Format: Others
Language:zh-TW
Published: 1997
Online Access:http://ndltd.ncl.edu.tw/handle/15577265198190832073
id ndltd-TW-085NTU00442090
record_format oai_dc
spelling ndltd-TW-085NTU004420902016-07-01T04:15:38Z http://ndltd.ncl.edu.tw/handle/15577265198190832073 Development of a Cardiac Output Measurement System using Thoracic Bioimpedance 研製以胸腔阻抗特性量取心輸出量 Kao, Hau-ping 高浩平 碩士 國立臺灣大學 電機工程學系 85 The research project is to use the bioelectric impedance measurement technique that is applied to measure the most important physilogical parameters of the cardiac-pulmonary organs, such as heart rate (HR),respiration rate(RR) and cardiac output (CO) and develop an impedance cardiography. A pair of flat mounted button type excitation electrodes and pick-up electrodes, home-made 100KHZ(1mA)sine ware stimulated current source, AC amplifier with gain 500 as a signal conditioning circuit and the low-pass filter as well as 12 bit analog to digital convector(A/D C) to process the signal and convert to the digital signal. A personal computer has been used to process and calculate the HR and RR parameters. The Kubicek's model is employed to calculate the cardiac output (CO). After electrical characterization and test of our designed and implemented ICG measurement system, we also carried out to measure 3 major physiological parameters of the cardiac- pulmonary organs. The preliminary experimental results of this home-made ICG measurement system showed that it has very good repetability and reliability. The accurary of the HR measurement is rough to 3% and CO value is within the reason- able range. The RR value is also presented satisfied results with- in 10% after the digital processing. However, the realisyic accuracy of this three physiological parameters indeed to perform the calibiation with the other methods in future clinic expermental study. Jin-Fu Chang 詹國禎 1997 學位論文 ; thesis 76 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立臺灣大學 === 電機工程學系 === 85 === The research project is to use the bioelectric impedance measurement technique that is applied to measure the most important physilogical parameters of the cardiac-pulmonary organs, such as heart rate (HR),respiration rate(RR) and cardiac output (CO) and develop an impedance cardiography. A pair of flat mounted button type excitation electrodes and pick-up electrodes, home-made 100KHZ(1mA)sine ware stimulated current source, AC amplifier with gain 500 as a signal conditioning circuit and the low-pass filter as well as 12 bit analog to digital convector(A/D C) to process the signal and convert to the digital signal. A personal computer has been used to process and calculate the HR and RR parameters. The Kubicek's model is employed to calculate the cardiac output (CO). After electrical characterization and test of our designed and implemented ICG measurement system, we also carried out to measure 3 major physiological parameters of the cardiac- pulmonary organs. The preliminary experimental results of this home-made ICG measurement system showed that it has very good repetability and reliability. The accurary of the HR measurement is rough to 3% and CO value is within the reason- able range. The RR value is also presented satisfied results with- in 10% after the digital processing. However, the realisyic accuracy of this three physiological parameters indeed to perform the calibiation with the other methods in future clinic expermental study.
author2 Jin-Fu Chang
author_facet Jin-Fu Chang
Kao, Hau-ping
高浩平
author Kao, Hau-ping
高浩平
spellingShingle Kao, Hau-ping
高浩平
Development of a Cardiac Output Measurement System using Thoracic Bioimpedance
author_sort Kao, Hau-ping
title Development of a Cardiac Output Measurement System using Thoracic Bioimpedance
title_short Development of a Cardiac Output Measurement System using Thoracic Bioimpedance
title_full Development of a Cardiac Output Measurement System using Thoracic Bioimpedance
title_fullStr Development of a Cardiac Output Measurement System using Thoracic Bioimpedance
title_full_unstemmed Development of a Cardiac Output Measurement System using Thoracic Bioimpedance
title_sort development of a cardiac output measurement system using thoracic bioimpedance
publishDate 1997
url http://ndltd.ncl.edu.tw/handle/15577265198190832073
work_keys_str_mv AT kaohauping developmentofacardiacoutputmeasurementsystemusingthoracicbioimpedance
AT gāohàopíng developmentofacardiacoutputmeasurementsystemusingthoracicbioimpedance
AT kaohauping yánzhìyǐxiōngqiāngzǔkàngtèxìngliàngqǔxīnshūchūliàng
AT gāohàopíng yánzhìyǐxiōngqiāngzǔkàngtèxìngliàngqǔxīnshūchūliàng
_version_ 1718328946328600576