Corrosion of HPC and Effect on the Pullout Resistance of Rebar

碩士 === 國立海洋大學 === 材料工程研究所 === 85 === The corrosion of steel in the concrete demage the bond of steel andconcret e and leads to construction falure .The qualityof construction is the most imp ortant requirement in civil engineering . Proper curing can...

Full description

Bibliographic Details
Main Authors: Jwo, Ying Yang, 卓益揚
Other Authors: C.C.Yang
Format: Others
Language:zh-TW
Published: 1997
Online Access:http://ndltd.ncl.edu.tw/handle/74981744466050603399
id ndltd-TW-085NTOU0159011
record_format oai_dc
spelling ndltd-TW-085NTOU01590112015-10-13T18:05:34Z http://ndltd.ncl.edu.tw/handle/74981744466050603399 Corrosion of HPC and Effect on the Pullout Resistance of Rebar 高性能混凝土腐蝕及腐蝕後拉拔行為探討 Jwo, Ying Yang 卓益揚 碩士 國立海洋大學 材料工程研究所 85 The corrosion of steel in the concrete demage the bond of steel andconcret e and leads to construction falure .The qualityof construction is the most imp ortant requirement in civil engineering . Proper curing can assume good qualit y of concrete structure . Recently,high performance concrete (HPC) becomes m ore popular because the durability requirement . The problems of corrosion in HPC should be noticed . Test results show tha t the specimens with lowest water/cement ratio have higheststrength developmen t ,pullout force and also corrosion resistance abilitybecause of the lowest po rosity . The specimens with highest water/cementratio have lowest strength dev elopment and durability. Specimens cured in 40 ℃ have denser organization so the strength development , corrosionresistance and pullout force are better th an the specimens cured in air . C.C.Yang R.Huang 楊仲家 黃 然 --- 1997 學位論文 ; thesis 98 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立海洋大學 === 材料工程研究所 === 85 === The corrosion of steel in the concrete demage the bond of steel andconcret e and leads to construction falure .The qualityof construction is the most imp ortant requirement in civil engineering . Proper curing can assume good qualit y of concrete structure . Recently,high performance concrete (HPC) becomes m ore popular because the durability requirement . The problems of corrosion in HPC should be noticed . Test results show tha t the specimens with lowest water/cement ratio have higheststrength developmen t ,pullout force and also corrosion resistance abilitybecause of the lowest po rosity . The specimens with highest water/cementratio have lowest strength dev elopment and durability. Specimens cured in 40 ℃ have denser organization so the strength development , corrosionresistance and pullout force are better th an the specimens cured in air .
author2 C.C.Yang
author_facet C.C.Yang
Jwo, Ying Yang
卓益揚
author Jwo, Ying Yang
卓益揚
spellingShingle Jwo, Ying Yang
卓益揚
Corrosion of HPC and Effect on the Pullout Resistance of Rebar
author_sort Jwo, Ying Yang
title Corrosion of HPC and Effect on the Pullout Resistance of Rebar
title_short Corrosion of HPC and Effect on the Pullout Resistance of Rebar
title_full Corrosion of HPC and Effect on the Pullout Resistance of Rebar
title_fullStr Corrosion of HPC and Effect on the Pullout Resistance of Rebar
title_full_unstemmed Corrosion of HPC and Effect on the Pullout Resistance of Rebar
title_sort corrosion of hpc and effect on the pullout resistance of rebar
publishDate 1997
url http://ndltd.ncl.edu.tw/handle/74981744466050603399
work_keys_str_mv AT jwoyingyang corrosionofhpcandeffectonthepulloutresistanceofrebar
AT zhuōyìyáng corrosionofhpcandeffectonthepulloutresistanceofrebar
AT jwoyingyang gāoxìngnénghùnníngtǔfǔshíjífǔshíhòulābáxíngwèitàntǎo
AT zhuōyìyáng gāoxìngnénghùnníngtǔfǔshíjífǔshíhòulābáxíngwèitàntǎo
_version_ 1718028704601341952