Corrosion of HPC and Effect on the Pullout Resistance of Rebar
碩士 === 國立海洋大學 === 材料工程研究所 === 85 === The corrosion of steel in the concrete demage the bond of steel andconcret e and leads to construction falure .The qualityof construction is the most imp ortant requirement in civil engineering . Proper curing can...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | zh-TW |
Published: |
1997
|
Online Access: | http://ndltd.ncl.edu.tw/handle/74981744466050603399 |
id |
ndltd-TW-085NTOU0159011 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-085NTOU01590112015-10-13T18:05:34Z http://ndltd.ncl.edu.tw/handle/74981744466050603399 Corrosion of HPC and Effect on the Pullout Resistance of Rebar 高性能混凝土腐蝕及腐蝕後拉拔行為探討 Jwo, Ying Yang 卓益揚 碩士 國立海洋大學 材料工程研究所 85 The corrosion of steel in the concrete demage the bond of steel andconcret e and leads to construction falure .The qualityof construction is the most imp ortant requirement in civil engineering . Proper curing can assume good qualit y of concrete structure . Recently,high performance concrete (HPC) becomes m ore popular because the durability requirement . The problems of corrosion in HPC should be noticed . Test results show tha t the specimens with lowest water/cement ratio have higheststrength developmen t ,pullout force and also corrosion resistance abilitybecause of the lowest po rosity . The specimens with highest water/cementratio have lowest strength dev elopment and durability. Specimens cured in 40 ℃ have denser organization so the strength development , corrosionresistance and pullout force are better th an the specimens cured in air . C.C.Yang R.Huang 楊仲家 黃 然 --- 1997 學位論文 ; thesis 98 zh-TW |
collection |
NDLTD |
language |
zh-TW |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 國立海洋大學 === 材料工程研究所 === 85 === The corrosion of steel in the concrete demage the bond of steel andconcret
e and leads to construction falure .The qualityof construction is the most imp
ortant requirement in civil engineering . Proper curing can assume good qualit
y of concrete structure . Recently,high performance concrete (HPC) becomes m
ore popular because the durability requirement . The problems of corrosion in
HPC should be noticed . Test results show tha
t the specimens with lowest water/cement ratio have higheststrength developmen
t ,pullout force and also corrosion resistance abilitybecause of the lowest po
rosity . The specimens with highest water/cementratio have lowest strength dev
elopment and durability. Specimens cured in 40 ℃ have denser organization so
the strength development , corrosionresistance and pullout force are better th
an the specimens cured in air .
|
author2 |
C.C.Yang |
author_facet |
C.C.Yang Jwo, Ying Yang 卓益揚 |
author |
Jwo, Ying Yang 卓益揚 |
spellingShingle |
Jwo, Ying Yang 卓益揚 Corrosion of HPC and Effect on the Pullout Resistance of Rebar |
author_sort |
Jwo, Ying Yang |
title |
Corrosion of HPC and Effect on the Pullout Resistance of Rebar |
title_short |
Corrosion of HPC and Effect on the Pullout Resistance of Rebar |
title_full |
Corrosion of HPC and Effect on the Pullout Resistance of Rebar |
title_fullStr |
Corrosion of HPC and Effect on the Pullout Resistance of Rebar |
title_full_unstemmed |
Corrosion of HPC and Effect on the Pullout Resistance of Rebar |
title_sort |
corrosion of hpc and effect on the pullout resistance of rebar |
publishDate |
1997 |
url |
http://ndltd.ncl.edu.tw/handle/74981744466050603399 |
work_keys_str_mv |
AT jwoyingyang corrosionofhpcandeffectonthepulloutresistanceofrebar AT zhuōyìyáng corrosionofhpcandeffectonthepulloutresistanceofrebar AT jwoyingyang gāoxìngnénghùnníngtǔfǔshíjífǔshíhòulābáxíngwèitàntǎo AT zhuōyìyáng gāoxìngnénghùnníngtǔfǔshíjífǔshíhòulābáxíngwèitàntǎo |
_version_ |
1718028704601341952 |