Kinetic Analysis of Continue-flow Sequencing Batch Reactor

碩士 === 國立中央大學 === 環境工程學系 === 85 === AbstractIn biological wastewater treatment systems, the removal efficiency of organic pollutants is depended on the operational parameters and conditions, and is correlatedwith the species of microorganism and its activ...

Full description

Bibliographic Details
Main Authors: kao, Chi-Ying, 高綺霙
Other Authors: Shu-Liang Laiw
Format: Others
Language:zh-TW
Published: 1997
Online Access:http://ndltd.ncl.edu.tw/handle/40385316271807102973
id ndltd-TW-085NCU00515026
record_format oai_dc
spelling ndltd-TW-085NCU005150262015-10-13T17:59:45Z http://ndltd.ncl.edu.tw/handle/40385316271807102973 Kinetic Analysis of Continue-flow Sequencing Batch Reactor 連續流SBR系統於自動即時監控下氮去除動力特性之研究 kao, Chi-Ying 高綺霙 碩士 國立中央大學 環境工程學系 85 AbstractIn biological wastewater treatment systems, the removal efficiency of organic pollutants is depended on the operational parameters and conditions, and is correlatedwith the species of microorganism and its activities. Therefore, it is required to maintain the species and its activities in processes control of biological wastewater treatment systems.In continue-flow sequencing batch reactor (CF-SBR) system, the main difference between the fixed-time and the real-time control is the foremost set the operation phase time in fixation to make sure the nitrification and denitrification are completed, thehindmost are real-time adjusts the cyclic duration to meet a time of treatment needs by on-line monitoring process parameters (pH, oxidation reduction potential and dissolved oxygen), it made the processes more flexible than the foremost. As mentioned above, base on the different character of two control strateges, the experiments of CF SBR using the real-time control show that the aerobic and anaerobic duration are shorter than fixed-time control in general. In order to know the effect of CF SBR system under the real-time control operation, this research measures the oxygen uptake rate in batch-tests to identify the activities of nitrosomonas and nitrobacter, and determine kinetics parameters of nitrification, includes maximum substrate removal rate, half-saturation coefficient and inhibit constant. It also measures the specific nitrate and nitrite utilization rates of denitrification with different COD: N ratio in batch-tests for investigation the kinetic of ammonia removal.The results of experiments shown that 1. nitrification kinetic parameters of fixed-time control strategy are r0,m=27.6 mg O2/g-hr, Kn=1.12 mg/l, Ki=4.92 mg/l for nitrosomonas and r0,m=9.0 mg O2/g-hr, Kn=0.7 mg/l, Ki=49.4 mg/l for nitrobacter. Nitrification kinetic parameters of real-time control strategy are r0,m=27.7 mg O2/g- hr, Kn=1.13 mg/l, Ki=5.91 mg/l for nitrosomonas and r0,m=7.9 mg O2/g-hr, Kn=0.84 mg/l, Ki=54.97 mg/l for nitrobacter, the kinetic parameters of both fixed and real-time control are similar. 2. both control strategies makes the same denitrofication rate in the same COD:N ratio. Otherwise, the aerobic duration measurement for real-time control is only about 3/4 of fixed-time control per day. These results indicate that using the real-time control not only can enhance the operation efficient of CF SBR system but can also maintain the same kinetic quality as using the fixed-time control. Shu-Liang Laiw 廖述良 1997 學位論文 ; thesis 114 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立中央大學 === 環境工程學系 === 85 === AbstractIn biological wastewater treatment systems, the removal efficiency of organic pollutants is depended on the operational parameters and conditions, and is correlatedwith the species of microorganism and its activities. Therefore, it is required to maintain the species and its activities in processes control of biological wastewater treatment systems.In continue-flow sequencing batch reactor (CF-SBR) system, the main difference between the fixed-time and the real-time control is the foremost set the operation phase time in fixation to make sure the nitrification and denitrification are completed, thehindmost are real-time adjusts the cyclic duration to meet a time of treatment needs by on-line monitoring process parameters (pH, oxidation reduction potential and dissolved oxygen), it made the processes more flexible than the foremost. As mentioned above, base on the different character of two control strateges, the experiments of CF SBR using the real-time control show that the aerobic and anaerobic duration are shorter than fixed-time control in general. In order to know the effect of CF SBR system under the real-time control operation, this research measures the oxygen uptake rate in batch-tests to identify the activities of nitrosomonas and nitrobacter, and determine kinetics parameters of nitrification, includes maximum substrate removal rate, half-saturation coefficient and inhibit constant. It also measures the specific nitrate and nitrite utilization rates of denitrification with different COD: N ratio in batch-tests for investigation the kinetic of ammonia removal.The results of experiments shown that 1. nitrification kinetic parameters of fixed-time control strategy are r0,m=27.6 mg O2/g-hr, Kn=1.12 mg/l, Ki=4.92 mg/l for nitrosomonas and r0,m=9.0 mg O2/g-hr, Kn=0.7 mg/l, Ki=49.4 mg/l for nitrobacter. Nitrification kinetic parameters of real-time control strategy are r0,m=27.7 mg O2/g- hr, Kn=1.13 mg/l, Ki=5.91 mg/l for nitrosomonas and r0,m=7.9 mg O2/g-hr, Kn=0.84 mg/l, Ki=54.97 mg/l for nitrobacter, the kinetic parameters of both fixed and real-time control are similar. 2. both control strategies makes the same denitrofication rate in the same COD:N ratio. Otherwise, the aerobic duration measurement for real-time control is only about 3/4 of fixed-time control per day. These results indicate that using the real-time control not only can enhance the operation efficient of CF SBR system but can also maintain the same kinetic quality as using the fixed-time control.
author2 Shu-Liang Laiw
author_facet Shu-Liang Laiw
kao, Chi-Ying
高綺霙
author kao, Chi-Ying
高綺霙
spellingShingle kao, Chi-Ying
高綺霙
Kinetic Analysis of Continue-flow Sequencing Batch Reactor
author_sort kao, Chi-Ying
title Kinetic Analysis of Continue-flow Sequencing Batch Reactor
title_short Kinetic Analysis of Continue-flow Sequencing Batch Reactor
title_full Kinetic Analysis of Continue-flow Sequencing Batch Reactor
title_fullStr Kinetic Analysis of Continue-flow Sequencing Batch Reactor
title_full_unstemmed Kinetic Analysis of Continue-flow Sequencing Batch Reactor
title_sort kinetic analysis of continue-flow sequencing batch reactor
publishDate 1997
url http://ndltd.ncl.edu.tw/handle/40385316271807102973
work_keys_str_mv AT kaochiying kineticanalysisofcontinueflowsequencingbatchreactor
AT gāoqǐyīng kineticanalysisofcontinueflowsequencingbatchreactor
AT kaochiying liánxùliúsbrxìtǒngyúzìdòngjíshíjiānkòngxiàdànqùchúdònglìtèxìngzhīyánjiū
AT gāoqǐyīng liánxùliúsbrxìtǒngyúzìdòngjíshíjiānkòngxiàdànqùchúdònglìtèxìngzhīyánjiū
_version_ 1718027618605858816