A Study on Mean Frequency Estimation of Doppler Blood Signal
碩士 === 國立交通大學 === 電信研究所 === 85 === Two significant building blocks in Color Flow Imaging systems have been discussed in this study. The first part is dedicated to clutter suppression. When the clutter is dominant as is normal in clinical e...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | zh-TW |
Published: |
1997
|
Online Access: | http://ndltd.ncl.edu.tw/handle/58625351359495438744 |
id |
ndltd-TW-085NCTU0436039 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-085NCTU04360392015-10-13T17:59:39Z http://ndltd.ncl.edu.tw/handle/58625351359495438744 A Study on Mean Frequency Estimation of Doppler Blood Signal 杜卜勒血流速度估測之研究 Hsieh, Yu-Tao 謝雨滔 碩士 國立交通大學 電信研究所 85 Two significant building blocks in Color Flow Imaging systems have been discussed in this study. The first part is dedicated to clutter suppression. When the clutter is dominant as is normal in clinical environment, FIR or IIR high-pass filters are used to suppress the low-frequency clutter component. Simulation results show that the transient effect can be mitigated even when very short data sequence was available to the IIR filter whose registers have been well-initialized. Another topic is concerned with mean frequency estimation of Doppler blood flow. Emphasis is placed on the AC (AutoCorrelation) and AR (AutoRegressive) methods. The AC estimator is easy to implement and superior to the conventional FFT estimator, but it lacks the capability of distinguishing between blood flow and clutter. By mapping phases to the spectral peaks of the backscattered signal, an AR estimator has the advantage of reliable estimation of blood flow without clutter suppression. Wen-Whei Chang 張文輝 1997 學位論文 ; thesis 65 zh-TW |
collection |
NDLTD |
language |
zh-TW |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 國立交通大學 === 電信研究所 === 85 === Two significant building blocks in Color Flow Imaging systems
have been discussed in this study. The first part is dedicated
to clutter suppression. When the clutter is dominant as is
normal in clinical environment, FIR or IIR high-pass filters are
used to suppress the low-frequency clutter component. Simulation
results show that the transient effect can be mitigated even
when very short data sequence was available to the IIR filter
whose registers have been well-initialized. Another topic is
concerned with mean frequency estimation of Doppler blood flow.
Emphasis is placed on the AC (AutoCorrelation) and AR
(AutoRegressive) methods. The AC estimator is easy to implement
and superior to the conventional FFT estimator, but it lacks the
capability of distinguishing between blood flow and clutter. By
mapping phases to the spectral peaks of the backscattered
signal, an AR estimator has the advantage of reliable estimation
of blood flow without clutter suppression.
|
author2 |
Wen-Whei Chang |
author_facet |
Wen-Whei Chang Hsieh, Yu-Tao 謝雨滔 |
author |
Hsieh, Yu-Tao 謝雨滔 |
spellingShingle |
Hsieh, Yu-Tao 謝雨滔 A Study on Mean Frequency Estimation of Doppler Blood Signal |
author_sort |
Hsieh, Yu-Tao |
title |
A Study on Mean Frequency Estimation of Doppler Blood Signal |
title_short |
A Study on Mean Frequency Estimation of Doppler Blood Signal |
title_full |
A Study on Mean Frequency Estimation of Doppler Blood Signal |
title_fullStr |
A Study on Mean Frequency Estimation of Doppler Blood Signal |
title_full_unstemmed |
A Study on Mean Frequency Estimation of Doppler Blood Signal |
title_sort |
study on mean frequency estimation of doppler blood signal |
publishDate |
1997 |
url |
http://ndltd.ncl.edu.tw/handle/58625351359495438744 |
work_keys_str_mv |
AT hsiehyutao astudyonmeanfrequencyestimationofdopplerbloodsignal AT xièyǔtāo astudyonmeanfrequencyestimationofdopplerbloodsignal AT hsiehyutao dùbolēixuèliúsùdùgūcèzhīyánjiū AT xièyǔtāo dùbolēixuèliúsùdùgūcèzhīyánjiū AT hsiehyutao studyonmeanfrequencyestimationofdopplerbloodsignal AT xièyǔtāo studyonmeanfrequencyestimationofdopplerbloodsignal |
_version_ |
1717786110308909056 |