A Study on Mean Frequency Estimation of Doppler Blood Signal

碩士 === 國立交通大學 === 電信研究所 === 85 === Two significant building blocks in Color Flow Imaging systems have been discussed in this study. The first part is dedicated to clutter suppression. When the clutter is dominant as is normal in clinical e...

Full description

Bibliographic Details
Main Authors: Hsieh, Yu-Tao, 謝雨滔
Other Authors: Wen-Whei Chang
Format: Others
Language:zh-TW
Published: 1997
Online Access:http://ndltd.ncl.edu.tw/handle/58625351359495438744
id ndltd-TW-085NCTU0436039
record_format oai_dc
spelling ndltd-TW-085NCTU04360392015-10-13T17:59:39Z http://ndltd.ncl.edu.tw/handle/58625351359495438744 A Study on Mean Frequency Estimation of Doppler Blood Signal 杜卜勒血流速度估測之研究 Hsieh, Yu-Tao 謝雨滔 碩士 國立交通大學 電信研究所 85 Two significant building blocks in Color Flow Imaging systems have been discussed in this study. The first part is dedicated to clutter suppression. When the clutter is dominant as is normal in clinical environment, FIR or IIR high-pass filters are used to suppress the low-frequency clutter component. Simulation results show that the transient effect can be mitigated even when very short data sequence was available to the IIR filter whose registers have been well-initialized. Another topic is concerned with mean frequency estimation of Doppler blood flow. Emphasis is placed on the AC (AutoCorrelation) and AR (AutoRegressive) methods. The AC estimator is easy to implement and superior to the conventional FFT estimator, but it lacks the capability of distinguishing between blood flow and clutter. By mapping phases to the spectral peaks of the backscattered signal, an AR estimator has the advantage of reliable estimation of blood flow without clutter suppression. Wen-Whei Chang 張文輝 1997 學位論文 ; thesis 65 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立交通大學 === 電信研究所 === 85 === Two significant building blocks in Color Flow Imaging systems have been discussed in this study. The first part is dedicated to clutter suppression. When the clutter is dominant as is normal in clinical environment, FIR or IIR high-pass filters are used to suppress the low-frequency clutter component. Simulation results show that the transient effect can be mitigated even when very short data sequence was available to the IIR filter whose registers have been well-initialized. Another topic is concerned with mean frequency estimation of Doppler blood flow. Emphasis is placed on the AC (AutoCorrelation) and AR (AutoRegressive) methods. The AC estimator is easy to implement and superior to the conventional FFT estimator, but it lacks the capability of distinguishing between blood flow and clutter. By mapping phases to the spectral peaks of the backscattered signal, an AR estimator has the advantage of reliable estimation of blood flow without clutter suppression.
author2 Wen-Whei Chang
author_facet Wen-Whei Chang
Hsieh, Yu-Tao
謝雨滔
author Hsieh, Yu-Tao
謝雨滔
spellingShingle Hsieh, Yu-Tao
謝雨滔
A Study on Mean Frequency Estimation of Doppler Blood Signal
author_sort Hsieh, Yu-Tao
title A Study on Mean Frequency Estimation of Doppler Blood Signal
title_short A Study on Mean Frequency Estimation of Doppler Blood Signal
title_full A Study on Mean Frequency Estimation of Doppler Blood Signal
title_fullStr A Study on Mean Frequency Estimation of Doppler Blood Signal
title_full_unstemmed A Study on Mean Frequency Estimation of Doppler Blood Signal
title_sort study on mean frequency estimation of doppler blood signal
publishDate 1997
url http://ndltd.ncl.edu.tw/handle/58625351359495438744
work_keys_str_mv AT hsiehyutao astudyonmeanfrequencyestimationofdopplerbloodsignal
AT xièyǔtāo astudyonmeanfrequencyestimationofdopplerbloodsignal
AT hsiehyutao dùbolēixuèliúsùdùgūcèzhīyánjiū
AT xièyǔtāo dùbolēixuèliúsùdùgūcèzhīyánjiū
AT hsiehyutao studyonmeanfrequencyestimationofdopplerbloodsignal
AT xièyǔtāo studyonmeanfrequencyestimationofdopplerbloodsignal
_version_ 1717786110308909056