The Research of Operational Stability and Efficiency of Man- Machine Interface For the Walking Aids

碩士 === 國立成功大學 === 工業設計學系 === 85 === Abstract Because of those limits to the lower-extremity disabled by theirmobility, they cannot attain those social activities freely and even cannothave the same op...

Full description

Bibliographic Details
Main Authors: Wong, Ruey-Jihn, 翁瑞津
Other Authors: Hsin-Hsi Lai
Format: Others
Language:zh-TW
Published: 1997
Online Access:http://ndltd.ncl.edu.tw/handle/34735021325087721590
id ndltd-TW-085NCKU0038001
record_format oai_dc
spelling ndltd-TW-085NCKU00380012015-10-13T12:15:18Z http://ndltd.ncl.edu.tw/handle/34735021325087721590 The Research of Operational Stability and Efficiency of Man- Machine Interface For the Walking Aids 下肢殘障者立姿康復輔行具於安全與穩定之人機介面適合度研究 Wong, Ruey-Jihn 翁瑞津 碩士 國立成功大學 工業設計學系 85 Abstract Because of those limits to the lower-extremity disabled by theirmobility, they cannot attain those social activities freely and even cannothave the same opportunities to the commons. By using walking-aided rehabilitation apparatus, those lower-extremity disabled are able to obtain the basic mobility. Meanwhile, helping them to be rehabilitated and to go back to those independently daily lives. Furthermore, helping them to go back to their own jobs. In the past years those researches related to the tools helping the limb-handicapped people were limited in the regions of wheelchairs and prosthetic limbs. The limb-handicapped can only choose their apparatuses by the experiences of the prosthetic-limb makers. However it could cause many injuries and problems. That's why we are engaged to study the walking-aided rehabilitation apparatus. This research discusses the needs and conditions to use the apparatus for those lower-extremity disabled by studying the types of limb-handicaps. At the meantime discussing the operation of apparatus realize the human-machine interface microscopic environment of walking-aided apparatus and the operation model for those lower extremity disabled to use the apparatus. Besides we perform an ergonomic experiment aimed to the walking-aided apparatus. This ergonomic experiment takes the normal people and the CVA(Cerebral Vascular Accident) patient as subjects of this experiment. By comparing these two groups to obtain the results, we realize how to help the lower-extremity disabled to increase their mobility.Therefore, we take the analysis of the data as the specifications and preferences to design apparatus in the future.Keywords: Lower Extremity Disabled, Walking Aided Apparatus, Man Machine Interface, Ergonomics Experiment. Hsin-Hsi Lai 賴新喜 1997 學位論文 ; thesis 95 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立成功大學 === 工業設計學系 === 85 === Abstract Because of those limits to the lower-extremity disabled by theirmobility, they cannot attain those social activities freely and even cannothave the same opportunities to the commons. By using walking-aided rehabilitation apparatus, those lower-extremity disabled are able to obtain the basic mobility. Meanwhile, helping them to be rehabilitated and to go back to those independently daily lives. Furthermore, helping them to go back to their own jobs. In the past years those researches related to the tools helping the limb-handicapped people were limited in the regions of wheelchairs and prosthetic limbs. The limb-handicapped can only choose their apparatuses by the experiences of the prosthetic-limb makers. However it could cause many injuries and problems. That's why we are engaged to study the walking-aided rehabilitation apparatus. This research discusses the needs and conditions to use the apparatus for those lower-extremity disabled by studying the types of limb-handicaps. At the meantime discussing the operation of apparatus realize the human-machine interface microscopic environment of walking-aided apparatus and the operation model for those lower extremity disabled to use the apparatus. Besides we perform an ergonomic experiment aimed to the walking-aided apparatus. This ergonomic experiment takes the normal people and the CVA(Cerebral Vascular Accident) patient as subjects of this experiment. By comparing these two groups to obtain the results, we realize how to help the lower-extremity disabled to increase their mobility.Therefore, we take the analysis of the data as the specifications and preferences to design apparatus in the future.Keywords: Lower Extremity Disabled, Walking Aided Apparatus, Man Machine Interface, Ergonomics Experiment.
author2 Hsin-Hsi Lai
author_facet Hsin-Hsi Lai
Wong, Ruey-Jihn
翁瑞津
author Wong, Ruey-Jihn
翁瑞津
spellingShingle Wong, Ruey-Jihn
翁瑞津
The Research of Operational Stability and Efficiency of Man- Machine Interface For the Walking Aids
author_sort Wong, Ruey-Jihn
title The Research of Operational Stability and Efficiency of Man- Machine Interface For the Walking Aids
title_short The Research of Operational Stability and Efficiency of Man- Machine Interface For the Walking Aids
title_full The Research of Operational Stability and Efficiency of Man- Machine Interface For the Walking Aids
title_fullStr The Research of Operational Stability and Efficiency of Man- Machine Interface For the Walking Aids
title_full_unstemmed The Research of Operational Stability and Efficiency of Man- Machine Interface For the Walking Aids
title_sort research of operational stability and efficiency of man- machine interface for the walking aids
publishDate 1997
url http://ndltd.ncl.edu.tw/handle/34735021325087721590
work_keys_str_mv AT wongrueyjihn theresearchofoperationalstabilityandefficiencyofmanmachineinterfaceforthewalkingaids
AT wēngruìjīn theresearchofoperationalstabilityandefficiencyofmanmachineinterfaceforthewalkingaids
AT wongrueyjihn xiàzhīcánzhàngzhělìzīkāngfùfǔxíngjùyúānquányǔwěndìngzhīrénjījièmiànshìhédùyánjiū
AT wēngruìjīn xiàzhīcánzhàngzhělìzīkāngfùfǔxíngjùyúānquányǔwěndìngzhīrénjījièmiànshìhédùyánjiū
AT wongrueyjihn researchofoperationalstabilityandefficiencyofmanmachineinterfaceforthewalkingaids
AT wēngruìjīn researchofoperationalstabilityandefficiencyofmanmachineinterfaceforthewalkingaids
_version_ 1716856922150273024