Particle Size Distribution of PAHs in the Air of Automobile Garage
碩士 === 國立成功大學 === 環境工程學系 === 84 === Due to poor ventilation, the air polluants in semi-closed garages are frequently accumulated during working hours, causing deteroration in the indoor air. Since some polycyclic aromatic hydrocarbons (...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | zh-TW |
Published: |
1996
|
Online Access: | http://ndltd.ncl.edu.tw/handle/84340445532628878895 |
id |
ndltd-TW-084NCKU0515026 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-084NCKU05150262016-02-05T04:16:28Z http://ndltd.ncl.edu.tw/handle/84340445532628878895 Particle Size Distribution of PAHs in the Air of Automobile Garage 汽車修護廠空氣中多環芳香烴之粒徑分佈特徵研究 Lin, Wei-An 林威安 碩士 國立成功大學 環境工程學系 84 Due to poor ventilation, the air polluants in semi-closed garages are frequently accumulated during working hours, causing deteroration in the indoor air. Since some polycyclic aromatic hydrocarbons (PAHs) found in the automobile exhaust are known to be highly carcinogenic or mutagenic, their concentrations and particle size distributions in the indoor and outdoor air at garages are of great concern. In this study two automobile garages were chosen, their indoor and outdoor air were sampled simultaneously by two PS-1 samplers and amultiple-orifice uniform deposite impacter (MOUDI). The samples were Soxhletextracted and analyzed by aan HP-5890 GC/FID for 16PAHs. The results show thatboth the total suspended particulate and the total-PAHs inthe indoor air weredistinctly higher than the values at their surrounding. Inside both garages, the total-PAHs and the toxic PAHs on the fine particles (d<2.5um) and the TSPwere all higher than the outdoor values. On fine particles inside the garagesthe toxic PAHs were 44% higher than the outdoor values. TSP inside was only 9%above the outside air. Both patterns of particle size distribution inside andoutside air was polluted by PAHs diffused out from within the garages, Insidethe garages the mass median diameters (MMD) were smaller than 3um, meaning that PAHs resided on fine suspended particles. Ta-Chang, Lin 林達昌 1996 學位論文 ; thesis 153 zh-TW |
collection |
NDLTD |
language |
zh-TW |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 國立成功大學 === 環境工程學系 === 84 === Due to poor ventilation, the air polluants in semi-closed
garages are frequently accumulated during working hours, causing
deteroration in the indoor air. Since some polycyclic aromatic
hydrocarbons (PAHs) found in the automobile exhaust are known to
be highly carcinogenic or mutagenic, their concentrations and
particle size distributions in the indoor and outdoor air at
garages are of great concern. In this study two automobile
garages were chosen, their indoor and outdoor air were sampled
simultaneously by two PS-1 samplers and amultiple-orifice
uniform deposite impacter (MOUDI). The samples were
Soxhletextracted and analyzed by aan HP-5890 GC/FID for 16PAHs.
The results show thatboth the total suspended particulate and
the total-PAHs inthe indoor air weredistinctly higher than the
values at their surrounding. Inside both garages, the total-PAHs
and the toxic PAHs on the fine particles (d<2.5um) and the
TSPwere all higher than the outdoor values. On fine particles
inside the garagesthe toxic PAHs were 44% higher than the
outdoor values. TSP inside was only 9%above the outside air.
Both patterns of particle size distribution inside andoutside
air was polluted by PAHs diffused out from within the garages,
Insidethe garages the mass median diameters (MMD) were smaller
than 3um, meaning that PAHs resided on fine suspended particles.
|
author2 |
Ta-Chang, Lin |
author_facet |
Ta-Chang, Lin Lin, Wei-An 林威安 |
author |
Lin, Wei-An 林威安 |
spellingShingle |
Lin, Wei-An 林威安 Particle Size Distribution of PAHs in the Air of Automobile Garage |
author_sort |
Lin, Wei-An |
title |
Particle Size Distribution of PAHs in the Air of Automobile Garage |
title_short |
Particle Size Distribution of PAHs in the Air of Automobile Garage |
title_full |
Particle Size Distribution of PAHs in the Air of Automobile Garage |
title_fullStr |
Particle Size Distribution of PAHs in the Air of Automobile Garage |
title_full_unstemmed |
Particle Size Distribution of PAHs in the Air of Automobile Garage |
title_sort |
particle size distribution of pahs in the air of automobile garage |
publishDate |
1996 |
url |
http://ndltd.ncl.edu.tw/handle/84340445532628878895 |
work_keys_str_mv |
AT linweian particlesizedistributionofpahsintheairofautomobilegarage AT línwēiān particlesizedistributionofpahsintheairofautomobilegarage AT linweian qìchēxiūhùchǎngkōngqìzhōngduōhuánfāngxiāngtīngzhīlìjìngfēnbùtèzhēngyánjiū AT línwēiān qìchēxiūhùchǎngkōngqìzhōngduōhuánfāngxiāngtīngzhīlìjìngfēnbùtèzhēngyánjiū |
_version_ |
1718180394694606848 |