Computer Assisted Determination of the Tumor Area and Location on Radiation Therapy Treatment System using Computed Tomography Images

碩士 === 國立清華大學 === 電機工程研究所 === 83 === In radiotheraphy, decreasing the total treatment dosage will reduce the side effect on a patient. On the contrary, decreasing the total treatment dosage lowers the tumor control probability of...

Full description

Bibliographic Details
Main Authors: Huan Chen, 陳煥
Other Authors: Hui Peng
Format: Others
Language:en_US
Published: 1995
Online Access:http://ndltd.ncl.edu.tw/handle/72994141298557320355
id ndltd-TW-083NTHU0442073
record_format oai_dc
spelling ndltd-TW-083NTHU04420732015-10-13T12:26:20Z http://ndltd.ncl.edu.tw/handle/72994141298557320355 Computer Assisted Determination of the Tumor Area and Location on Radiation Therapy Treatment System using Computed Tomography Images 放射治療電腦輔助確定腫瘤及照射區域方法之研究 Huan Chen 陳煥 碩士 國立清華大學 電機工程研究所 83 In radiotheraphy, decreasing the total treatment dosage will reduce the side effect on a patient. On the contrary, decreasing the total treatment dosage lowers the tumor control probability of the patients. Accurate tumor localization for radiotherapy treatment appears to be very important because it allows to increase the dosage on the tumor and reduce simultaneously the dosage on the normal tissues. We develop computer techniques to determine the relative positions of the patient under radiotherapy treatment and under computed tomography scan and to find the tumor location and area on simulation film from the computed tomography(CT). The simulation film is an X-ray film of the simulator for determining radiation area before real treatment on the linear accelerator. This approach uses a quantized rank circular minimum mean square error(QRCMMSE) operator to find the optimal matching center between CT projection image and simulation film. The location and area of tumor are consequently determined by projecting the CT slices with the tumor contours, marked by the oncologist previously, onto a transparency to be overlaid with the simulation film. This computer techniques can also revise the rotation error if existing. Experimental results show that the algorithm are quite accurate in performing the desired task. This technique could be need to give more effective, less harmful and more efficient radiation therapy treatment. Hui Peng 彭惠 1995 學位論文 ; thesis 70 en_US
collection NDLTD
language en_US
format Others
sources NDLTD
description 碩士 === 國立清華大學 === 電機工程研究所 === 83 === In radiotheraphy, decreasing the total treatment dosage will reduce the side effect on a patient. On the contrary, decreasing the total treatment dosage lowers the tumor control probability of the patients. Accurate tumor localization for radiotherapy treatment appears to be very important because it allows to increase the dosage on the tumor and reduce simultaneously the dosage on the normal tissues. We develop computer techniques to determine the relative positions of the patient under radiotherapy treatment and under computed tomography scan and to find the tumor location and area on simulation film from the computed tomography(CT). The simulation film is an X-ray film of the simulator for determining radiation area before real treatment on the linear accelerator. This approach uses a quantized rank circular minimum mean square error(QRCMMSE) operator to find the optimal matching center between CT projection image and simulation film. The location and area of tumor are consequently determined by projecting the CT slices with the tumor contours, marked by the oncologist previously, onto a transparency to be overlaid with the simulation film. This computer techniques can also revise the rotation error if existing. Experimental results show that the algorithm are quite accurate in performing the desired task. This technique could be need to give more effective, less harmful and more efficient radiation therapy treatment.
author2 Hui Peng
author_facet Hui Peng
Huan Chen
陳煥
author Huan Chen
陳煥
spellingShingle Huan Chen
陳煥
Computer Assisted Determination of the Tumor Area and Location on Radiation Therapy Treatment System using Computed Tomography Images
author_sort Huan Chen
title Computer Assisted Determination of the Tumor Area and Location on Radiation Therapy Treatment System using Computed Tomography Images
title_short Computer Assisted Determination of the Tumor Area and Location on Radiation Therapy Treatment System using Computed Tomography Images
title_full Computer Assisted Determination of the Tumor Area and Location on Radiation Therapy Treatment System using Computed Tomography Images
title_fullStr Computer Assisted Determination of the Tumor Area and Location on Radiation Therapy Treatment System using Computed Tomography Images
title_full_unstemmed Computer Assisted Determination of the Tumor Area and Location on Radiation Therapy Treatment System using Computed Tomography Images
title_sort computer assisted determination of the tumor area and location on radiation therapy treatment system using computed tomography images
publishDate 1995
url http://ndltd.ncl.edu.tw/handle/72994141298557320355
work_keys_str_mv AT huanchen computerassisteddeterminationofthetumorareaandlocationonradiationtherapytreatmentsystemusingcomputedtomographyimages
AT chénhuàn computerassisteddeterminationofthetumorareaandlocationonradiationtherapytreatmentsystemusingcomputedtomographyimages
AT huanchen fàngshèzhìliáodiànnǎofǔzhùquèdìngzhǒngliújízhàoshèqūyùfāngfǎzhīyánjiū
AT chénhuàn fàngshèzhìliáodiànnǎofǔzhùquèdìngzhǒngliújízhàoshèqūyùfāngfǎzhīyánjiū
_version_ 1716858256481058816