A Microwave Counter Produced by Photoconductive Sampling

碩士 === 國立交通大學 === 光電(科學)研究所 === 83 === At present,frequency counter is the most accurate instrument for measuring signal frequency.Since such counter consists of a digital logic circuit,the upper limit of countable frequency will be limited...

Full description

Bibliographic Details
Main Authors: Huo-Feng Chiu, 邱和風
Other Authors: Chen-Shiung Chang
Format: Others
Language:zh-TW
Published: 1995
Online Access:http://ndltd.ncl.edu.tw/handle/09953375566809563089
id ndltd-TW-083NCTU0123012
record_format oai_dc
spelling ndltd-TW-083NCTU01230122015-10-13T12:53:37Z http://ndltd.ncl.edu.tw/handle/09953375566809563089 A Microwave Counter Produced by Photoconductive Sampling 以光導反取樣技術至作微波晶頻率計數器 Huo-Feng Chiu 邱和風 碩士 國立交通大學 光電(科學)研究所 83 At present,frequency counter is the most accurate instrument for measuring signal frequency.Since such counter consists of a digital logic circuit,the upper limit of countable frequency will be limited by the response speed of this circuit.Although some strategies of transformation do increase this upper limit a little ,the situation is not much improved.In our experiment, we adopt the fast speed electronic devices(photoconductive) switch instead of the usual devices.such novel counter,we study the countable frequency range,sensitivity and stability of the system and the accuracy of measurement. So far our counter can count signal frequency more then 3.5 GHz with sensitivity 1dBm and the input signal frequency modulation tolerance can attain 40MHz,the accuracy of frequency attains the order of Hz . Chen-Shiung Chang 張振雄 1995 學位論文 ; thesis 56 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立交通大學 === 光電(科學)研究所 === 83 === At present,frequency counter is the most accurate instrument for measuring signal frequency.Since such counter consists of a digital logic circuit,the upper limit of countable frequency will be limited by the response speed of this circuit.Although some strategies of transformation do increase this upper limit a little ,the situation is not much improved.In our experiment, we adopt the fast speed electronic devices(photoconductive) switch instead of the usual devices.such novel counter,we study the countable frequency range,sensitivity and stability of the system and the accuracy of measurement. So far our counter can count signal frequency more then 3.5 GHz with sensitivity 1dBm and the input signal frequency modulation tolerance can attain 40MHz,the accuracy of frequency attains the order of Hz .
author2 Chen-Shiung Chang
author_facet Chen-Shiung Chang
Huo-Feng Chiu
邱和風
author Huo-Feng Chiu
邱和風
spellingShingle Huo-Feng Chiu
邱和風
A Microwave Counter Produced by Photoconductive Sampling
author_sort Huo-Feng Chiu
title A Microwave Counter Produced by Photoconductive Sampling
title_short A Microwave Counter Produced by Photoconductive Sampling
title_full A Microwave Counter Produced by Photoconductive Sampling
title_fullStr A Microwave Counter Produced by Photoconductive Sampling
title_full_unstemmed A Microwave Counter Produced by Photoconductive Sampling
title_sort microwave counter produced by photoconductive sampling
publishDate 1995
url http://ndltd.ncl.edu.tw/handle/09953375566809563089
work_keys_str_mv AT huofengchiu amicrowavecounterproducedbyphotoconductivesampling
AT qiūhéfēng amicrowavecounterproducedbyphotoconductivesampling
AT huofengchiu yǐguāngdǎofǎnqǔyàngjìshùzhìzuòwēibōjīngpínlǜjìshùqì
AT qiūhéfēng yǐguāngdǎofǎnqǔyàngjìshùzhìzuòwēibōjīngpínlǜjìshùqì
AT huofengchiu microwavecounterproducedbyphotoconductivesampling
AT qiūhéfēng microwavecounterproducedbyphotoconductivesampling
_version_ 1716868599032840192