Feasibility of Using Small Steel Plates to Replace Regular Steel Beams as Test Specimens in the Assessment of Fire Rating of Coating materials

碩士 === 國立臺灣科技大學 === 營建工程技術學系 === 82 === The fireproof capacity of coated steel structure is maintain by fire resistance rating(t), and the rating is close to section scale factor (W/D, unit weight/section fired circumambience) of steel structure and coati...

Full description

Bibliographic Details
Main Authors: Yi-Chu Tang, 唐益楚
Other Authors: Ching-Yuan Lin
Format: Others
Language:zh-TW
Published: 1994
Online Access:http://ndltd.ncl.edu.tw/handle/45661636929412788867
id ndltd-TW-082NTUST512018
record_format oai_dc
spelling ndltd-TW-082NTUST5120182016-02-08T04:06:26Z http://ndltd.ncl.edu.tw/handle/45661636929412788867 Feasibility of Using Small Steel Plates to Replace Regular Steel Beams as Test Specimens in the Assessment of Fire Rating of Coating materials 以小尺度鋼鈑取代鋼樑進行被覆材料耐火性能之評估 Yi-Chu Tang 唐益楚 碩士 國立臺灣科技大學 營建工程技術學系 82 The fireproof capacity of coated steel structure is maintain by fire resistance rating(t), and the rating is close to section scale factor (W/D, unit weight/section fired circumambience) of steel structure and coating material thickness(T). The study is according to the view of section scale factor transfer, put all kinds of H style to be 45cm2 but differ thickness steel plate, make to small scale specimen, therefore, applying standard curve time-temperature under CNS 12514 to proceed truly fire resisting test of single degree heated model for small scale specimen ,and realize the truly relationship of t, T and W/D. However, according to theory analysis the feasibility of using small-scaled specimen replace coating steel structure and proceed the appraise of fireproof capacity. The kinds of coating steel structures are so much, so only study the model of wet coated structure (horizon-heating) painted around H style section.@ The study result detect that the mutidegree coating steel beam structure will transfer single degree small scale specimen and proceed fire resisting test by section scale factor, but must consider water evaporate condition and the affect of small specimen lost heat in high temperature. During the relationship of t, T and W/D, t is proportional with T and W/D. Form the result, the paper point of sprayed thickness of beam transfer formula common using now, and the managing method for examining the external qualify materials that recognized by the domestic authorities concerned, to provide the actual suggestion for the accordance of improving and examining. Ching-Yuan Lin 林慶元 1994 學位論文 ; thesis 106 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立臺灣科技大學 === 營建工程技術學系 === 82 === The fireproof capacity of coated steel structure is maintain by fire resistance rating(t), and the rating is close to section scale factor (W/D, unit weight/section fired circumambience) of steel structure and coating material thickness(T). The study is according to the view of section scale factor transfer, put all kinds of H style to be 45cm2 but differ thickness steel plate, make to small scale specimen, therefore, applying standard curve time-temperature under CNS 12514 to proceed truly fire resisting test of single degree heated model for small scale specimen ,and realize the truly relationship of t, T and W/D. However, according to theory analysis the feasibility of using small-scaled specimen replace coating steel structure and proceed the appraise of fireproof capacity. The kinds of coating steel structures are so much, so only study the model of wet coated structure (horizon-heating) painted around H style section.@ The study result detect that the mutidegree coating steel beam structure will transfer single degree small scale specimen and proceed fire resisting test by section scale factor, but must consider water evaporate condition and the affect of small specimen lost heat in high temperature. During the relationship of t, T and W/D, t is proportional with T and W/D. Form the result, the paper point of sprayed thickness of beam transfer formula common using now, and the managing method for examining the external qualify materials that recognized by the domestic authorities concerned, to provide the actual suggestion for the accordance of improving and examining.
author2 Ching-Yuan Lin
author_facet Ching-Yuan Lin
Yi-Chu Tang
唐益楚
author Yi-Chu Tang
唐益楚
spellingShingle Yi-Chu Tang
唐益楚
Feasibility of Using Small Steel Plates to Replace Regular Steel Beams as Test Specimens in the Assessment of Fire Rating of Coating materials
author_sort Yi-Chu Tang
title Feasibility of Using Small Steel Plates to Replace Regular Steel Beams as Test Specimens in the Assessment of Fire Rating of Coating materials
title_short Feasibility of Using Small Steel Plates to Replace Regular Steel Beams as Test Specimens in the Assessment of Fire Rating of Coating materials
title_full Feasibility of Using Small Steel Plates to Replace Regular Steel Beams as Test Specimens in the Assessment of Fire Rating of Coating materials
title_fullStr Feasibility of Using Small Steel Plates to Replace Regular Steel Beams as Test Specimens in the Assessment of Fire Rating of Coating materials
title_full_unstemmed Feasibility of Using Small Steel Plates to Replace Regular Steel Beams as Test Specimens in the Assessment of Fire Rating of Coating materials
title_sort feasibility of using small steel plates to replace regular steel beams as test specimens in the assessment of fire rating of coating materials
publishDate 1994
url http://ndltd.ncl.edu.tw/handle/45661636929412788867
work_keys_str_mv AT yichutang feasibilityofusingsmallsteelplatestoreplaceregularsteelbeamsastestspecimensintheassessmentoffireratingofcoatingmaterials
AT tángyìchǔ feasibilityofusingsmallsteelplatestoreplaceregularsteelbeamsastestspecimensintheassessmentoffireratingofcoatingmaterials
AT yichutang yǐxiǎochǐdùgāngbǎnqǔdàigāngliángjìnxíngbèifùcáiliàonàihuǒxìngnéngzhīpínggū
AT tángyìchǔ yǐxiǎochǐdùgāngbǎnqǔdàigāngliángjìnxíngbèifùcáiliàonàihuǒxìngnéngzhīpínggū
_version_ 1718182074987315200