Utilization of maximum motion range in functional of fingers
碩士 === 國立成功大學 === 醫學工程學系 === 82 === The purpose of this study is to evaluate the motor function fingers by using a 3-Dimensional Motion Analysis System. Ten healthy subjects (80 fingers) and 46 patients (107 fingers) wereinstructed...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | zh-TW |
Published: |
1994
|
Online Access: | http://ndltd.ncl.edu.tw/handle/06043078072996407388 |
id |
ndltd-TW-082NCKU0530016 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-082NCKU05300162015-10-13T12:43:35Z http://ndltd.ncl.edu.tw/handle/06043078072996407388 Utilization of maximum motion range in functional of fingers 最大手指運動範圍在評估手指運動功能之應用 Sune-June Liou 劉勝賢 碩士 國立成功大學 醫學工程學系 82 The purpose of this study is to evaluate the motor function fingers by using a 3-Dimensional Motion Analysis System. Ten healthy subjects (80 fingers) and 46 patients (107 fingers) wereinstructed to move their fungers from full-extension to on. The largest range of each finger's movement was calculated and the function of motion (FM) were compare with the function of motion (FA) index of AMA (American Medical Association). The results indicate that the relationship between FA and AROM (Active Range of Motion) is linear, however, relationship FM and AROM is nonlinear. Both Standard Diveration (S.D) and Coefficient of Varience (C.V) of FM's and FA's are large. Howerver, both FM and FA made no difference by each cases. The C.V of a normal finger is lower than that of patients. Patient's C.V will be different in various cases. We realized that the FA index is over estimated and the application range of our FM is very extensive. Each joint of a finger is independent of AROM when they are normal. PIP is the main casse for FM and MP is the second. During the rehabilit ation period, the FM of the injured fingers increase stably, but FA and TAM increase more at the begining and less at the period. Fong-Chin Su You-Li Chou Haw-Yeu Chiou 蘇芳慶 周有禮 邱浩遠 1994 學位論文 ; thesis 38 zh-TW |
collection |
NDLTD |
language |
zh-TW |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 國立成功大學 === 醫學工程學系 === 82 === The purpose of this study is to evaluate the motor function
fingers by using a 3-Dimensional Motion Analysis System.
Ten healthy subjects (80 fingers) and 46 patients (107 fingers)
wereinstructed to move their fungers from full-extension to
on. The largest range of each finger's movement was calculated
and the function of motion (FM) were compare with the function
of motion (FA) index of AMA (American Medical Association).
The results indicate that the relationship between FA and
AROM (Active Range of Motion) is linear, however,
relationship FM and AROM is nonlinear. Both Standard
Diveration (S.D) and Coefficient of Varience (C.V) of FM's
and FA's are large. Howerver, both FM and FA made no
difference by each cases. The C.V of a normal finger is lower
than that of patients. Patient's C.V will be different in
various cases. We realized that the FA index is over
estimated and the application range of our FM is very
extensive. Each joint of a finger is independent of AROM
when they are normal. PIP is the main casse for FM and MP is
the second. During the rehabilit ation period, the FM of
the injured fingers increase stably, but FA and TAM increase
more at the begining and less at the period.
|
author2 |
Fong-Chin Su |
author_facet |
Fong-Chin Su Sune-June Liou 劉勝賢 |
author |
Sune-June Liou 劉勝賢 |
spellingShingle |
Sune-June Liou 劉勝賢 Utilization of maximum motion range in functional of fingers |
author_sort |
Sune-June Liou |
title |
Utilization of maximum motion range in functional of fingers |
title_short |
Utilization of maximum motion range in functional of fingers |
title_full |
Utilization of maximum motion range in functional of fingers |
title_fullStr |
Utilization of maximum motion range in functional of fingers |
title_full_unstemmed |
Utilization of maximum motion range in functional of fingers |
title_sort |
utilization of maximum motion range in functional of fingers |
publishDate |
1994 |
url |
http://ndltd.ncl.edu.tw/handle/06043078072996407388 |
work_keys_str_mv |
AT sunejuneliou utilizationofmaximummotionrangeinfunctionaloffingers AT liúshèngxián utilizationofmaximummotionrangeinfunctionaloffingers AT sunejuneliou zuìdàshǒuzhǐyùndòngfànwéizàipínggūshǒuzhǐyùndònggōngnéngzhīyīngyòng AT liúshèngxián zuìdàshǒuzhǐyùndòngfànwéizàipínggūshǒuzhǐyùndònggōngnéngzhīyīngyòng |
_version_ |
1716864527855779840 |